39
■
Check the units
■
Check that the base, stand and other
fi
ttings of the outdoor unit are not decayed or corroded.
■
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
■
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
• If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the
case.
■
Before a long idle period
1.
Operate the FAN only for several hours on a
fi
ne day to dry
out the inside.
• Press
and select “ ” operation.
• Press
and start the operation.
2.
After operation stops, turn off the breaker for the room air
conditioner.
3.
Clean the air
fi
lters and set them again.
4.
Take out batteries from the remote controller.
■
We recommend periodical maintenance
• In certain operating conditions, the inside of the air conditioner may get foul after several seasons of use, resulting in poor
performance. It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user.
• For specialist maintenance, contact the service shop where you bought the air conditioner.
• The maintenance cost must be born by the user.
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required depending on European or local legislation.
Please contact your local dealer for more information.
Important information regarding the refrigerant used
This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere.
Refrigerant type:
GWP
(1)
value:
675
R32
NOTICE
regarding tCO
2
eq
In Europe, the
greenhouse gas emissions
of the total refrigerant charge in the system (expressed as tonnes CO
2
-equivalent)
is used to determine the maintenance intervals. Follow the applicable legislation.
Formula to calculate the greenhouse gas emissions:
GWP value of the refrigerant × Total refrigerant charge [in kg] / 1000
Care and Cleaning