
6
|
Unit installation
Installer reference guide
24
FTXP-M + FTXF-D + FTXF-A + ATXF-A
Daikin room air conditioner
4P513661-12L – 2021.07
6.3 Mounting the indoor unit
In this chapter
6.3.1 To install the mounting plate
1
Install the mounting plate temporarily.
2
Level the mounting plate.
3
Mark the centres of the drilling points on the wall using a tape measure.
Position the end of tape measure at symbol " ".
4
Finish the installation by securing the mounting plate on the wall using
M4×25L screws (field supply).
INFORMATION
The removed pipe port cover can be kept in the mounting plate pocket.
A
990
295
170
60
170
44
.5
44
.5
122
121.5
56.5
56.5
404
475
PIPING HOLE
CENTER:170mm
TO THE LEFT
PIPING HOLE
CENTER:170mm
(mm)
A
A
PIPING HOLE
CENTER:170mm
TO THE LEFT
PIPING HOLE
CENTER:170mm
TO THE RIGHT
e
d
e
d
b
a
c
a
c
a
a
g
h
f2
a
i
f1
a
Recommended mounting plate fixing spots
f1
Measure point for piping hole center " " (to left)
b
Pocket for the pipe port cover
f2
Measure point for piping hole center " " (to right)
c
Tabs for placing a spirit level
g
Gas pipe end
d
Through-the-wall hole Ø65 mm
h
Liquid pipe end
e
Drain hose position
i
Center of the unit
6.3.2 To drill a wall hole
CAUTION
For walls containing a metal frame or a metal board, use a wall embedded pipe and
wall cover in the feed-through hole to prevent possible heat, electrical shock, or fire.
NOTICE
Be sure to seal the gaps around the pipes with sealing material (field supply), in order
to prevent water leakage.
1
Bore a 65 mm large feed-through hole in the wall with a downward slope
towards the outside.
2
Insert a wall embedded pipe into the hole.
Содержание ATXF50A2V1B
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ...4P513661 12L 2021 07 Copyright 2021 Daikin Verantwortung für Energie und Umwelt ...