English
2
EnglishEnglish
Safety Precautions
Accessories
–
Operation limits
Use the system in the following temperature and humidity ranges for safe and effective operation.
(a)
To avoid condensation and water dripping out of the unit. If the temperature or the humidity is beyond these conditions, safety
devices may be put in action and the air conditioner may not operate.
The setting temperature range of the remote controller is:
CAUTION
• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
• Only qualified personnel can handle, fill, purge and dispose of the refrigerant.
• While following the instructions in this installation manual, install drain piping to ensure proper drainage
and insulate piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.
• This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for
commercial and household use by lay persons.
• Sound pressure level is less than 70 dB(A).
Mounting plate
1
Remote controller holder
1
Operation manual
1
Titanium apatite deodorizing
filter
2
Dry battery AAA. LR03
(alkaline) - for
2
Installation manual
1
Wireless remote controller
1
Indoor unit fixing screw
(M4 × 12L)
2
Cooling
Heating
Outdoor temperature
–10~46°C
–15~24°C
Indoor temperature
18~32°C
10~30°C
Indoor humidity
≤
80%
(a)
Cooling operation
Heating operation
AUTO operation
18-32°C
10-30°C
18-30°C
Indoor unit
A
H
A
D
G
B
E
C
H
C
F
3P393185-3W.book Page 2 Wednesday, January 25, 2017 5:50 PM