1-14
LED Indicator Lights: Normal Operation And Fault Conditions For Cooling/Heat Pump Unit
COOL/HEAT
(GREEN/RED)
Normal Operation/Fault Indication
Action
Error Code
Green
Cool mode
-
-
Red
Heat mode
-
-
Red
Auto mode in Heating operation
-
-
Green
Auto mode in Cooling operation
-
-
Timer on
-
-
Sleep mode on
-
-
Fan mode on
-
-
Dry mode on
-
-
1 time
Room air sensor contact
Loose/Short
Call your dealer
Blink E1
3 times
Outdoor coil sensor open
Call your dealer
Blink E3
2 times
Indoor coil sensor open
Call your dealer
Blink E2
1 time
Compressor overload/ Indoor coil sensor short/
outdoor coil sensor short
Call your dealer
Blink E4
Red
Defrost operation
-
-
3 times
Gas leak
Call your dealer
Blink E5
6 times
Hardware error (tact switch pin short)
Call your dealer
Blink E8
4 times
No feedback from indoor fan
Call your dealer
Blink E9