SiEN04-306D
Specifications
Specifications
27
50Hz 230V
Note:
MAX. interunit piping length: 30m
MIN. interunit piping length: 1.5m
MAX. interunit height difference: 20m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Model
Indoor Units
ATXS50DVMB
Outdoor Units
ARXS50C(2)VMB
Cooling
Heating
Capacity
Rated (Min.~Max.)
kW
5.0 (0.9~5.8)
5.8 (0.9~7.5)
Btu/h
17,070 (3,070~19,800)
19,800 (3,070~25,610)
kcal/h
4,300 (770~4,990)
4,990 (770~6,450)
Moisture Removal
L/h
2.9
—
Running Current (Rated)
A
7.3
7.5
Power Consumption
Rated (Min.~Max.)
W
1,660 (450~2,300)
1,700 (450~2,580)
Power Factor
%
98.9
98.6
COP
W/W
3.01
3.41
Piping
Connections
Liquid
mm
φ
6.4
Gas
mm
φ
12.7
Drain
mm
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
Indoor Unit
ATXS50DVMB
Front Panel Color
White
Air Flow Rate
m
3
/min
(cfm)
H
11.4 (402)
12.6 (445)
M
9.7 (342)
10.8 (381)
L
8.0 (282)
8.9 (314)
SL
7.1 (251)
7.7 (272)
Fan
Type
Cross Flow Fan
Motor Output
W
40
Speed
Steps
5 Steps, Silent and Auto
Air Direction Control
Right, Left, Horizontal and Downward
Air Filter
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.18
0.20
Power Consumption (Rated)
W
40
45
Power Factor
%
96.6
97.8
Temperature Control
Microcomputer Control
Dimensions (H×W×D)
mm
290×795×238
Packaged Dimensions (H×W×D)
mm
280×840×338
Weight
kg
9
Gross Weight
kg
13
Operation
Sound
H/M/L/SL
dBA
44/40/35/32
42/38/33/30
Sound Power
H
dBA
63
60
Outdoor Unit
ARXS50C(2)VMB
Casing Color
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Model
2YC32HXD
Motor Output
W
1,500
Refrigerant
Oil
Model
FVC50K
Charge
L
0.65
Refrigerant
Model
R-410A
Charge
kg
1.20
Air Flow Rate
(H/L)
m
3
/min
47.7/44.1
44.1/44.1
cfm
1,684/1,557
1,557/1,557
Fan
Type
Propeller
Motor Output
W
53
Running Current (Rated)
A
6.82
7.30
Power Consumption (Rated)
W
1,620
1,655
Power Factor
%
99.0
98.6
Starting Current
A
7.5
Dimensions (H×W×D)
mm
735×825×300
Packaged Dimensions (H×W×D)
mm
784×960×390
Weight
kg
49
Gross Weight
kg
53
Operation
Sound
H/L
dBA
47/—
48/—
Sound Power
H
dBA
63
64
Drawing No.
3D047938
Conversion Formula
kcal/h=kW×860
Btu/h=kW×3414
cfm=m
3
/min×35.3
Cooling
Heating
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m
Содержание ARXS50C2VMB
Страница 109: ...Instruction SiEN04 306D 100 System Configuration ...
Страница 199: ...Outdoor Unit SiEN04 306D 190 Removal Procedure ...
Страница 200: ...SiEN04 306D Others 191 Part 8 Others 1 Others 192 1 1 Test Run from the remote control 192 1 2 Jumper Settings 193 ...
Страница 203: ...Others SiEN04 306D 194 Others ...
Страница 214: ...SiEN04 306D Wiring Diagrams Appendix 205 FTKD18 24 28BVMS ...
Страница 216: ...SiEN04 306D Wiring Diagrams Appendix 207 RKD18 24 28BVMS ...
Страница 217: ...Wiring Diagrams SiEN04 306D 208 Appendix ...