7/8
Breadcrumb
Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.8
[9-06]
R/W
37~depending on outdoor unit, step: 1°C
55°C
A.8
[9-07]
5
A.8
[9-08]
22
A.8
[9-09]
R/W
3~10°C, step: 1°C
5°C
A.8
[9-0A]
5
A.8
[9-0B]
R/W
0: Quick
1: Slow
A.8
[9-0C]
R/W
1~6°C, step: 0,5°C
1 °C
A.8
[9-0D]
R/W
0~8, step:1
0 : 100%
1~4 : 80~50%
5~8 : 80~50%
6
A.8
[9-0E]
6
A.8
[A-00]
0
A.8
[A-01]
0 (*3)
3 (*4)
A.8
[A-02]
0 (*3)
1 (*4)
A.8
[A-03]
0
A.8
[A-04]
0
A.8
[B-00]
0
A.8
[B-01]
0
A.8
[B-02]
0
A.8
[B-03]
0
A.8
[B-04]
0
A.8
[C-00]
R/W
0: Solar priority
1: Heat pump priority
A.8
[C-01]
0
A.8
[C-02]
R/W
0: No
1: Bivalent
2: -
3: -
A.8
[C-03]
R/W
-25~25°C, step: 1°C
0°C
A.8
[C-04]
R/W
2~10°C, step: 1°C
3°C
A.8
[C-05]
R/W
1: Thermo ON/OFF
2: C/H request
A.8
[C-06]
R/W
0: -
1: Thermo ON/OFF
2: C/H request
A.8
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
A.8
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
A.8
[C-09]
R/W
0: Normally open
1: Normally closed
A.8
[C-0A]
0
A.8
[C-0C]
R/W
0~7
0
A.8
[C-0D]
R/W
0~7
0
A.8
[C-0E]
R/W
0~7
0
A.8
[D-00]
R/W
0: None
1: BSH only
2: BUH only
3: All heaters
A.8
[D-01]
R/W
0: No
1: Open tariff
2: Closed tariff
3: Thermostat
A.8
[D-02]
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
A.8
[D-03]
R/W
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C (from -4 to 4°C)
A.8
[D-04]
R/W
0: No
1: Pwr consmp ctrl
A.8
[D-05]
R/W
0: Forced off
1: As normal
A.8
[D-07]
R/W
0: No
1: Yes
A.8
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.8
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.8
[D-0A]
0
A.8
[D-0B]
2
A.8
[D-0C]
R/W
0~49
0
A.8
[D-0D]
R/W
0~49
0
What is the maximum desired LWT for add. zone in heating?
--
--
What is the desired delta T in heating?
--
What emitter type is connected to the main LWT zone?
Room temperature hysteresis.
Pump speed limitation
--
--
--
--
--
--
--
--
--
--
--
Domestic heating water priority.
--
Is an external backup heat source connected?
Bivalent activation temperature.
Bivalent hysteresis temperature.
What is the thermo request contact type for the main zone?
What is the thermo request contact type for the add. zone?
What is the unit control method in space operation?
Which type of external sensor is installed?
What is the required alarm output contact type?
--
Which heaters are permitted if prefer. kWh rate PS is cut?
Forced off contact type
Which type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
High electricity price decimal (Do not use)
Medium electricity price decimal (Do not use)
Low electricity price decimal (Do not use)
Is a demand PCB connected?
Is the pump allowed to run if prefer. kWh rate PS is cut?
Is a solar kit connected?
Is an external kWh meter used for power measurement?
Is an external kWh meter used for power measurement?
--
--
What is the high electricity price (Do not use)
What is the medium electricity price (Do not use)
(*1) EHBH*_(*2) EHVH*_
(*3) *04/08*_(*4) *11/16*
4P449974-1 - 2016.06