7 Installation
Installer reference guide
30
EPGA11~ EABH/9W
Daikin Altherma – Low temperature split
4P556069-1 – 2018.10
NOTICE
If the unit is installed in a cold climate, take adequate
measures so that the evacuated condensate CANNOT
freeze.
Drain holes (dimensions in mm)
160
620
261.5
119
161
260
285
279
345
595
416
262
38
71
C
D
E
D
D
D
D
A
B
A
Discharge side
B
Distance between anchor points
C
Bottom frame
D
Drain holes
E
Knockout hole for snow
NOTICE
If drain holes of the outdoor unit are covered by a mounting
base or by floor surface, raise the unit to provide a free
space of more than 150 mm under the outdoor unit.
≥150 mm
7.3.6
To fix the fluorinated greenhouse gases
label
1
Fill in the label as follows:
RXXX
d
Contains fluorinated greenhouse gases
kg
tCO
2
eq
GWP × kg
1000
=
GWP: XXX
a
b
c
a
If a multilingual fluorinated greenhouse gases label is
delivered with the unit (see accessories), peel off the
applicable language and stick it on top of
a
.
b
Total refrigerant charge
c
Quantity of fluorinated greenhouse gases
of the total
refrigerant charge expressed as tonnes CO
2
equivalent.
d
GWP = Global warming potential
NOTICE
Applicable legislation on
fluorinated greenhouse gases
requires that the refrigerant charge of the unit is indicated
both in weight and CO
2
equivalent.
Formula to calculate the quantity in CO
2
equivalent
tonnes:
GWP value of the refrigerant × total refrigerant
charge [in kg] / 1000
2
Fix the label on the inside of the outdoor unit near the gas and
liquid stop valves.
7.3.7
To prevent the outdoor unit from falling
over
In case the unit is installed in places where strong wind can tilt the
unit, take following measure:
1
Prepare 2 cables as indicated in the following illustration (field
supply).
2
Place the 2 cables over the outdoor unit.
3
Insert a rubber sheet between the cables and the outdoor unit
to prevent the cables from scratching the paint (field supply).
4
Attach the ends of the cables and tighten them.
7.4
Mounting the indoor unit
7.4.1
About mounting the indoor unit
Typical workflow
Mounting the indoor unit typically consists of the following stages:
1
Installing the indoor unit.
7.4.2
Precautions when mounting the indoor
unit
INFORMATION
Also read the precautions and requirements in the
following chapters:
▪ General safety precautions
▪ Preparation
7.4.3
To install the indoor unit
1
Fix the wall bracket (accessory) to the wall (level) with 2 Ø8 mm
bolts.
2×
a
a
Optional: If you want to fix the unit to the wall from inside
the unit, provide an additional screw plug.
2
Lift the unit.