Daikin Altherma EKHWE150A3V3 Скачать руководство пользователя страница 9

EKHWE150~3 E300A3Z2

Domestic hot water tank for air to water heat pump system

4PW43396-1D

Installation manual

7

T

ROUBLESHOOTING

This section provides useful information for diagnosing and correct-
ing certain troubles which may occur in the unit.

General guidelines

Before starting the troubleshooting procedure, carry out a thorough
visual inspection of the unit and look for obvious defects such as
loose connections or defective wiring.

Before contacting your local dealer, read this chapter carefully, it will
save you time and money.

When a safety device was activated, stop the unit and find out why
the safety device was activated before resetting it. Under no circum-
stances safety devices may be bridged or changed to a value other
than the factory setting. If the cause of the problem cannot be found,
call your local dealer

General symptoms

Symptom 1: No water flow from hot taps

Symptom 2: Water from hot taps is cold

T

ECHNICAL

 

SPECIFICATIONS

Domestic hot water tank specifications

When carrying out an inspection on the supply panel or on
the switch box of the unit, always make sure that the circuit
breaker of the unit is switched off.

P

OSSIBLE

 

CAUSES

C

ORRECTIVE

 

ACTION

The main water supply is off.

Check that all shut off valves of the 
water circuit are completely open.

P

OSSIBLE

 

CAUSES

C

ORRECTIVE

 

ACTION

The thermal cut-out(s) has/have 
operated

• Check and reset button(s).
• Put the thermostat setting for 

domestic hot water on the indoor unit 
to 

75°C.

• Check if thermistor is correctly 

installed in thermistor socket.

The indoor unit (EKHBH/X) is not 
operating.

Check the indoor unit (EKHBH/X) 
operation. Refer to the manual 
delivered with the indoor unit.
If any faults are suspected, contact 
your local dealer.

EKHWE150A3V3

EKHWET150A3V3

EKHWE200A3V3

EKHWE200A3Z2

EKHWE300A3V3

EKHWE300A3Z2

Volume

150 l

150 l

200 l

200 l

300 l

300 l

Internal heat exchanger volume

2 l

2 l

3  l

3  l

3  l

3  l

Overall dimensions (Ø x H)

545 x 1150 mm

545 x 1150 mm

545 x 1525 mm

545 x 1525 mm

660 x 1525 mm

660 x 1525 mm

Booster heater, power supply

230 V 50 Hz 1P

230 V 50 Hz 1P

230 V 50 Hz 1P

400 V 50 Hz 2P

230 V 50 Hz 1P

400 V 50 Hz 2P

Booster heater, running current

13 A

13 A

13 A

7.5 A

13 A

7.5 A

Booster heater, capacity

3 kW

3 kW

3 kW

3 kW

3 kW

3 kW

Connections

Refer to 

"Main components" on page 2

Weight (empty)

80 kg

82 kg

104 kg

104 kg

140 kg

140 kg

Mounting

Floor

Wall

Floor

Floor

Floor

Floor

Maximum pressure

10 bar

10 bar

10 bar

10 bar

10 bar

10 bar

Maximum domestic hot water 
temperature

75°C

75°C

75°C

75°C

75°C

75°C

Maximum temperature through 
heat exchanger

110°C

110°C

110°C

110°C

110°C

110°C

Содержание Altherma EKHWE150A3V3

Страница 1: ...INSTALLATION MANUAL EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3 EKHWE200A3Z2 EKHWE300A3Z2 Domestic hot water tank for air to water heat pump system ...

Страница 2: ... 30 30 50 700 300 440 500 4 5 30 30 700 400 705 220 255 280 35 115 775 1150 13 21 355 440 50 EKHWE150 300 EKHWET150 D1 1150 775 280 255 35 545 1525 925 280 410 35 545 1525 851 210 410 27 660 H1 H2 H3 H4 H5 Ø D1 150 200 EKHWE 300 A A A A 16 16 16 400 400 0 400 77 111 38 67 44 2 1 3 ...

Страница 3: ... EKHWET150A3V3 EKHWE200A3V3 EKHWE200A3Z2 EKHWE300A3V3 EKHWE300A3Z2 Domestic hot water tank for air to water heat pump system Installation manual READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE IMPROPER INSTALLATION OR ATTACHMENT OF EQUIPMENT OR ACCESSORIES COULD RESULT IN ELECTRIC SHOCK SHORT CIRCUIT LEAKS FIRE OR OTHER DAMAGE TO THE EQU...

Страница 4: ...stic hot water quality must be according to EN directive 98 83 EC A drain device should be installed on the cold water connection on the domestic hot water tank For safety reasons it is not allowed to add ethylene glycol to the water circuit Adding ethylene glycol might lead to contamination of the domestic water if a leakage would occur in the heat exchanger coil It is important that the storage ...

Страница 5: ...d back siphonage it is advised to install a non return valve on the water inlet of the domestic hot water tank in accordance with local and national regulations Installing the domestic hot water tank 1 Check if all domestic hot water tank accessories see Accessories on page 1 are enclosed 2 When floor mounting place the domestic hot water tank on a level surface If required adjust the legs at the ...

Страница 6: ...tions refer to Field wiring in the indoor unit installation manual supplied with the EKHBH X unit Installation in accordance with figure A and figure B Installation in accordance with figure C and figure D If the valve is not positioned in this way before mounting the motor the valve will give way to both domestic water and room heating during operation Installation in accordance with figure A and...

Страница 7: ...ector connected to the contactor K3M in the socket X13A on the PCB 5 Plug the thermistor cable connector in the socket X9A on the PCB 6 Connect the prewired earth wires of the terminal block X3M and X4M to the earthing screw 7 Connect the booster heater power supply and thermal protection cable field supply to terminal X4M earth 1 2 and X2M 13 14 8 Connect the booster heater power supply cable to ...

Страница 8: ...le the booster heater and the heat exchanger 3 Once every 2 year Anode Check if the anode is not deteriorated If the diameter of the anode has decreased with 10 mm or more make sure to replace it original diameter is 33 mm A4P K6M F2B K3M K7M 2 1 X4M 4a OPTIONAL X2M 21 20 Q2L 3 wayvalve 2 wayvalve 12 11 4 thermostat 2 1 3 5 6 7 8 9 10 13 19 thermal fuse 14 15 16 17 18 SOLARPUMP N L L2 L1 X3M 230V ...

Страница 9: ...in water supply is off Check that all shut off valves of the water circuit are completely open POSSIBLE CAUSES CORRECTIVE ACTION The thermal cut out s has have operated Check and reset button s Put the thermostat setting for domestic hot water on the indoor unit to 75 C Check if thermistor is correctly installed in thermistor socket The indoor unit EKHBH X is not operating Check the indoor unit EK...

Страница 10: ...4PW43396 1D Copyright Daikin ...

Отзывы: