4.15. Field settings

The configuration of the Daikin system is done through field settings.

In this operation manual all field settings related to the operation of
the unit and user demand are explained. A list of all those field
settings and default values is given under 

"4.16. Field settings table"

on page 20

. In this same list, we provided for 2 columns to register

the date and value of altered field settings at variance with the default
value.

For a total list of field settings, refer to the installation manual.

All field settings are accessible and programmable through the user
interface on the indoor unit.

Each field setting is assigned a 3-digit number or code, for example
[5-03], which is indicated on the user interface display. The first digit
[5] indicates the 'first code' or field setting group. The second and
third digit [03] together indicate the 'second code'. 

Procedure

To change one or more field settings, proceed as follows.

1

Press the 

 button for a minimum of 5 seconds to enter FIELD

SET MODE.
The 

 icon (3) will be displayed. The current selected field

setting code is indicated 

(2), with the set value displayed to

the right 

 (1).

2

Press the 

 button to select the appropriate field setting

first code.

3

Press the 

 button to select the appropriate field setting

second code.

4

Press the 

 button and 

 button to change

the set value of the select field setting.

5

Save the new value by pressing the 

 button.

6

Repeat step 2 through 4 to change other field settings as
required.

7

When finished, press the 

 button to exit FIELD SET MODE.

NOTE

Changes made to a specific  field setting are only
stored when the 

 button is pressed. Navigating to a

new  field setting code or pressing the 

 button will

discard the change made.

NOTE

Before shipping, the set values have been set as
shown under 

"4.16. 

Field settings table" on

page 20

.

When exiting FIELD SET MODE, "

88

" may be

displayed on the remote controller LCD while the
unit initializes itself.

2

3

1

When running through the field settings you may
notice that there are some more field settings as there
are mentioned in the 

"4.16. Field settings table" on

page 20

.  These  field settings are not applicable

and may not be changed!

For more information about installation related setting,
see installation manual of the indoor unit. For settings
different from the default value, contact your installer.

Содержание Altherma EKHVMRD50ABV1

Страница 1: ...OPERATION MANUAL EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1 Daikin Altherma indoor unit ...

Страница 2: ...wledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children shall be supervised to ensure that they do not play with the appliance 1 DEFINITIONS Installation manual Instruction manual specified for a certain product or application explaining how to install configure and maintain it Danger Indicates an imminently ha...

Страница 3: ...g The more detailed information of how the unit must be operated is explained in the chapter 4 Operation of the unit on page 3 The quick start up offers the user the possibility to start up the system before reading the entire manual Space heating operation NOTE An EKHVMRD and EKHVMYD indoor unit can only be connected to an EMRQ outdoor unit The installation of the indoor unit s is described in th...

Страница 4: ...eating only if domestic hot water tank option is installed Automatic storage daily water heat up once during night and or once during day Turn on field setting 1 00 and or 1 02 and then push the button See Automatic storage on page 8 The icon will display Hot water will be produced at next scheduled action When water heat up starts the icon will be blinking 1 second interval Manual storage one tim...

Страница 5: ...r to Field settings in the installation manual the weather dependent set point button will not be operable 26 INSPECTION TEST OPERATION BUTTON This button is used for installation purposes and changing field settings Refer to 4 15 Field settings on page 19 27 PROGRAMMING BUTTON This multi purpose button is used to program the controller The function of the button depends on the actual status of th...

Страница 6: ...aving water temperature which you want to be used to heat up your system for detailed information see Leaving water temperature control on page 6 Automatic setback function Setback function provides the possibility to lower the room temperature The setback function can for instance be activated during the night because the temperature demands during night and day are not the same The setback funct...

Страница 7: ...al room thermostat 1 Press the button 1 time to select weather dependent set point operation or 2 times when the remote controller room thermostat function is used Icon appears on the display as well as the shift value The shift value is not shown in case it is 0 2 Use the and buttons to set the shift value Range for the shift value 5 C to 5 C Icon will be displayed as long as the weather dependen...

Страница 8: ...edule timer function 3 Use the and buttons to select the leaving water temperature which you want to be used to cool down your system for detailed information see Leaving water temperature control on page 6 Leaving water temperature control In this mode cooling will be activated as required by the water temperature set point The set point can be set manually or through the schedule timer Selecting...

Страница 9: ...Therefore it is recommended to use this function b 04 Automatic maximum domestic hot water storage temperature default 70 C NOTE Any domestic water heating operation is impossible when the domestic hot water tank is not installed A Storage operation if activated B Reheat operation if activated C Disinfection operation if activated Field settings D Disinfection operation temperature 5 00 e g 70 C E...

Страница 10: ...estic water heating modes on page 8 Disinfection operation This mode will disinfect the domestic hot water tank by periodically heating the domestic water to a specific temperature During the operation of this mode the icon will be blinking rapidly with 0 5 second intervals The disinfection temperature set point is a field setting as are the retention time day and hour Refer to 4 15 Field settings...

Страница 11: ...t possible If you are using the remote controller room temperature control When the reheat temperature is reached the further heat up of the domestic hot water tank will be decided by the remote controller room thermostat in order to prevent the room temperature to drop too much If you are using the external room thermostat When the reheat temperature is reached the further heat up of the domestic...

Страница 12: ...stays enabled When pushing the button The schedule timer for space heating and domestic water heating along with the quiet mode will be stopped and will not start again The schedule timer icon will not be displayed anymore 1 Schedule timer 2 Setback function 3 When both setback function and schedule timer are enabled A Setback function t Time T Temperature set point Room temperature Leaving water ...

Страница 13: ...n can be used Reheat the reheat function can be activated next to or separate from the automatic storage operation if the user wants to keep the domestic hot water tank at the minimum reheat temperature Next to the standard domestic water heating operation modes it is also possible to freely program the domestic water heating operation through the schedule timer refer to Programming domestic water...

Страница 14: ...programmed for the same day and at the same time only the action with the highest action number will be executed Example You can always alter add or remove the programmed actions later NOTE If the auto restart function is disabled the schedule timer will not be activated when power returns to the unit after a power supply failure Press the button to enable the schedule timer again When power retur...

Страница 15: ...ature 10 Use the and buttons to set the room temperature 11 Use the button to select to switch heating and the remote controller off to select automatic temperature calculation for leaving water temperature Use the and buttons to set the appropriate shift value refer to 4 3 Space heating operation on page 5 for more information about weather dependent set point 12 Repeat steps 7 to 11 to program t...

Страница 16: ...ime 8 Use the and buttons to set the leaving water temperature 9 Use the and buttons to set the room temperature 10 Use the button to select to switch cooling and the remote controller off 11 Repeat steps 6 to 10 to program the other actions When all actions have been programmed make sure that the display shows the highest action number you would like to save 12 Press the button for 5 seconds to s...

Страница 17: ...ppears 7 Use the button to select the action number you would like to program or to modify 8 Use the and buttons to set the correct action time 9 Use the button to select or deselect as action 10 Repeat steps 7 to 9 to program the other actions of the selected mode When all actions have been programmed make sure that the display shows the highest action number you would like to save 11 Press the b...

Страница 18: ... program or to modify 7 Use the and buttons to set the correct action time 8 Use the button to select or deselect as action 9 Repeat steps 6 to 8 to program the other actions of the selected mode When all actions have been programmed make sure that the display shows the highest action number you would like to save 10 Press the button for 5 seconds to store the programmed actions If the button is p...

Страница 19: ...copied You can return to step 2 by pressing the button Deleting one or more programmed actions Deleting one or more programmed actions is done at the same time as storing the programmed actions When all actions for one day have been programmed make sure that the display shows the highest action number you would like to save By pressing the button for 5 seconds you store all actions except those wi...

Страница 20: ...on 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed to the right 1 2 Press the button to select the appropriate field setting first code 3 Press the button to select the appropriate field setting second code 4 Press the button and button to change the set value of the select field setting 5 Save the new value by pressing the button 6 Repeat st...

Страница 21: ...eather dependent set point 00 Low ambient temperature Lo_A 10 20 5 1 C 01 High ambient temperature Hi_A 15 10 20 1 C 02 Set point at low ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 Disinfection operation day selection Fri Mon Sun 02 Disinfection operation start time 23 00 0 0...

Страница 22: ...ture limits 00 Installation related setting a 80 37 80 1 C 01 Installation related setting a 25 25 37 1 C 02 Installation related setting a 20 18 22 1 C 03 Installation related setting a 5 5 18 1 C 04 Not applicable Do not change the default value 0 d Domestic water heating retention times 00 Installation related setting a 10 5 20 1 01 Installation related setting a 30 10 60 5 02 Installation rela...

Страница 23: ...o not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance with the applicable legislation Units must be treated at a specialized treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative cons...

Страница 24: ...NOTES ...

Страница 25: ...NOTES ...

Страница 26: ...NOTES ...

Страница 27: ......

Страница 28: ...4P404418 1 2015 04 Copyright 2015 Daikin ...

Отзывы: