6 Maintenance and service

User reference guide

21

EHVZ04~16S18CB
Daikin Altherma – Low temperature split
4P401674-1 – 2015.02

▪ Make  sure  the  desired  DHW  tank  temperature  is  NOT  too  high.

Example: 

After installation, lower the DHW tank temperature daily

by 1°C and check if you still have enough hot water.

▪ Program  to  turn  ON  the  domestic  hot  water  pump  only  during

periods of the day when instant hot water is necessary. 

Example:

In the morning and evening.

6

Maintenance and service

6.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.

As end user, you have to:

▪ Keep the area around the unit clean.

▪ Keep the user interface clean with a soft damp cloth. Do NOT use

any detergents.

Refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R410A

Global warming potential value: 2087.5

Periodical  inspections  for  refrigerant  leaks  may  be  required
depending on the applicable legislation. Please contact your installer
for more information.

6.2

To find the contact/helpdesk
number

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go  to  [6.3.2]: 

  >  Information  >  Error  handling  >  Contact/

helpdesk number.

7

Troubleshooting

7.1

Overview: Troubleshooting

If a malfunction occurs,   is displayed on the home pages. You can
press 

 to display more information about the malfunction.

For  the  symptoms  listed  below,  you  can  try  to  solve  the  problem
yourself. For any other problem, contact your installer. You can find
the contact/helpdesk number via the user interface.

7.2

To check the error history

Prerequisite: 

Only available if   is displayed on the home pages.

1

Go to [6.3.1]: 

 > Information > Error handling > Error history.

7.3

To check the warning history

Prerequisite: 

Only available if   is displayed on the home pages.

1

Go  to  [6.3.1]: 

  >  Information  >  Error  handling  >  Warning

history.

7.4

Symptom: You are feeling too cold
(hot) in your living room

Possible cause

Corrective action

The desired room temperature is
too low (high).

Increase (decrease) the desired
room temperature.

If the problem recurs daily, do
one of the following:

▪ Increase  (decrease)  the  room

temperature preset value.

▪ Adjust  the  room  temperature

schedule.

The desired room temperature
cannot be reached.

Increase the desired leaving
water temperature in accordance
with the heat emitter type.

7.5

Symptom: The water at the tap is
too cold

Possible cause

Corrective action

You ran out of domestic hot
water because of unusual high
consumption.

If you immediately need domestic
hot water, activate the DHW tank
booster mode. However, this
consumes extra energy.

If you can wait, overrule
(increase) the active or next
scheduled desired temperature
so that more hot water will be
produced exceptionally.

If the problems recurs daily, do
one of the following:

▪ Increase 

the 

DHW 

tank

temperature preset value.

▪ Adjust 

the 

DHW 

tank

temperature 

schedule.

Example: 

Program 

to

additionally 

heat 

up 

the

DHW  tank  to  a  preset  value
(Storage  eco  =  lower  tank
temperature) during the day.

The desired DHW tank
temperature is too low.

7.6

Symptom: Heat pump failure

When the heat pump fails to operate the backup heater can serve as
an  emergency  heater  and  either  automatically  or  non-automatically
take  over  the  heat  load.  When  auto  emergency  is  activated  and  a
heat  pump  failure  occurs,  the  backup  heater  will  automatically  take
over  the  heat  load.  When  a  heat  pump  failure  occurs  and  auto
emergency  is  not  activated,  the  domestic  hot  water  and  space
heating operations will stop and need to be recovered manually. The
user interface will then ask you to confirm whether the backup heater
can take over the heat load or not. When the heat pump fails,   will
appear on the user interface.

Содержание Altherma EHVZ08S18CB

Страница 1: ...User reference guide Daikin Altherma Low temperature split English User reference guide Daikin Altherma Low temperature split EHVZ04S18CB EHVZ08S18CB EHVZ16S18CB...

Страница 2: ...ctions 15 4 7 Preset values and schedules 16 4 7 1 Using preset values 16 4 7 2 Using and programming schedules 16 4 7 3 Schedules Example 17 4 7 4 Predefined schedules Room temperature leaving water...

Страница 3: ...for reuse By ensuring waste batteries are disposed of correctly you will help to prevent potential negative consequences for the environment and human health 2 About this document Thank you for purch...

Страница 4: ...taller settings 4 2 The user interface at a glance 4 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home page Goes to the default home page when you are in the menu...

Страница 5: ...water temperature LWT add DHW tank temperature Tank To go to a home page 1 Press Result One of the home pages is displayed 2 Press again to display the next home page if any 4 3 2 Using the menu struc...

Страница 6: ...emperature 2 Check the following If Then the temperature control is Main zone Additional zone if any Room temperature is listed under 6 1 Information Sensor information Room thermostat control Go to n...

Страница 7: ...d temperature 22 0 C Desired temperature To temporarily overrule the room temperature schedule 1 Go to the room temperature home page Room 2 Use or to adjust the temperature To change the mode from sc...

Страница 8: ...mfort will be used until 02 00 After that the schedule will be used again Usage example You go away for a couple of hours If you are in the following situation You are using the following room tempera...

Страница 9: ...ess or to adjust overrule To adjust the leaving water temperature additional 1 Go to the additional leaving water temperature home page LWT add 2 Press or to adjust Example 45 C 47 C INFORMATION In ca...

Страница 10: ...temperature home page LWT add 2 Press or to adjust Example 45 C 47 C INFORMATION In case of weather dependency an offset value can be modified 4 5 Domestic hot water control 4 5 1 About domestic hot w...

Страница 11: ...in and the DHW tank temperature decreases again At 00 00 the next day the cycle repeats In scheduled mode you can do the following You can Location Read out the active or next scheduled desired temper...

Страница 12: ...ode About the DHW tank booster mode You can use the DHW tank booster mode to immediately start heating up the water to the preset value Storage comfort However this consumes extra energy To check if t...

Страница 13: ...F to ensure the heating capacity of the system However during the afternoon the baby is sleeping and you want it to be quiet Then you can do the following Prerequisite You switched the permission leve...

Страница 14: ...lect No and press Usage example You go away during the winter If you are in the following situation In 2 days you go away for 2 weeks during the winter You want to save energy but prevent your house f...

Страница 15: ...30 Actual temperature Room Scheduled Mon Tue To configure which home pages are made available to the end user Prerequisite You switched the permission level to Advanced end user 1 Go to 7 1 4 User set...

Страница 16: ...alue Eco preset value Custom temperature Main leaving water temperature Additional leaving water temperature Program when the additional leaving water temperature is turned ON and OFF Control Possible...

Страница 17: ...and press 2 Select User defined 1 User defined 2 or User defined 3 and press 3 Change the name and press Only applicable for room temperature schedules Example MyWeekSchedule To select which schedule...

Страница 18: ...Set weather dependent 2 For main leaving water temperature zone 7 7 1 modify with and confirm with 3 If applicable for additional leaving water temperature zone 7 7 2 modify with and confirm with Set...

Страница 19: ...Error handling User permission level Actuators Operation modes Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User...

Страница 20: ...the DHW tank booster mode is active the risk of space heating and capacity shortage comfort problems is significant In case of frequent domestic hot water operation frequent and long space heating in...

Страница 21: ...eck the warning history Prerequisite Only available if is displayed on the home pages 1 Go to 6 3 1 Information Error handling Warning history 7 4 Symptom You are feeling too cold hot in your living r...

Страница 22: ...et of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the product User Person who is owner of the product and or operat...

Страница 23: ......

Страница 24: ...4P401674 1 2015 02 Copyright 2015 Daikin...

Отзывы: