If… is displayed
Then…
15:20
12.0°C
16
2013
Holiday
Mon
Feb
Until
Actual temp.
Holiday mode (Away) is
activated and running.
To configure the holiday (when you stay at home)
Prerequisite:
You switched the permission level to Advanced end
user.
1
Go to [2.2]:
> Holiday > Holiday mode.
2
Select Home.
3
Configure the holiday mode settings (when you stay at home).
4
Activate the holiday mode.
Possible holiday mode settings (when you stay at home)
Setting
Description
From and Until
First and last day of your holiday.
Use day
schedule
Day schedule used during your holiday.
Example:
Saturday
INFORMATION
Switch to Adv. end user if you want to change the Use day
schedule setting.
To configure the holiday (when you go away)
Prerequisite:
You switched the permission level to Advanced end
user.
1
Go to [2.2]:
> Holiday > Holiday mode.
2
Select Leave.
3
Configure the holiday mode settings (when you go away).
4
Activate the holiday mode.
Possible holiday mode settings (when you go away)
Setting
Description
From and Until
First and last day of your holiday.
Operation mode Operation mode used during your holiday.
Heating
Set point used during your holiday when the unit
is operating in heating mode.
DHW
Turn ON or OFF domestic hot water operation
during your holiday.
INFORMATION
You can only change the From and Until settings in the
End user level. For changing the other settings, you have
to switch to Adv. end user level.
To activate or deactivate the holiday mode
Prerequisite:
You have configured the holiday.
1
Go to [2.1]:
> Holiday > Holiday.
2
Do one of the following:
▪ To activate, select Yes and press
.
▪ To deactivate, select No and press
.
Usage example: You go away during the winter
If you are in the following situation:
▪ In 2 days, you go away for 2 weeks during the winter.
▪ You want to save energy, but prevent your house from freezing.
Then you can do the following:
Prerequisite:
You switched the permission level to Advanced end
user.
1
Configure the holiday. Go to [2]:
> Holiday, and configure
the following settings:
Setting
Value
Holiday mode
Away
From
2 February 2014
Until
16 February 2014
Operation mode
Heating
Heating
12°C
2
Activate the holiday mode.
▪ Go to [2.1]:
> Holiday > Holiday.
▪ Select Yes and press
.
Advantage:
▪ Before and after your holiday, your normal schedule will be used.
▪ During your holiday, you save energy and prevent your house
from freezing.
Usage example: You come home during your holiday
If you are in the following situation:
▪ You configured and activated the holiday mode (Away).
▪ During your holiday, you come home for a few hours and want to
use your normal schedule.
Then you can do the following:
1
Deactivate the holiday mode.
2
When you go away again, activate the holiday mode again.
Advantage:
You do NOT have to change your schedule or holiday configuration.
4.6.4
Reading out information
To read out information
Prerequisite:
You switched the permission level to Advanced end
user.
1
Go to [6]:
> Information.
Possible read-out information
In menu…
You can read out…
[6.1] Sensor information
Room, tank or DHW, outside,
and leaving water temperature.
(If applicable)
[6.2] Energy metering
Produced energy, consumed
electricity, and consumed gas.
[6.3] Error handling
Error history and contact/
helpdesk number.
[6.4] User permission level
Current user permission level.
[6.5] Actuators
Status/mode of each actuator.
Example:
Domestic hot water
pump ON/OFF.
[6.6] Operation modes
Current operation mode.
Example:
Defrost/oil return
mode.
[6.7] Running hours
Running hours of the system.
[6.8] Version
Version information about the
system.