background image

4 Operation

User reference guide

14

EHVZ04~16S18CB

Daikin Altherma – Low temperature split

4P401674-1 – 2015.02

If… is displayed

Then…

15:20

12.0°C

16

2013

Holiday

Mon

Feb

Until
Actual temp.

Holiday mode (Away) is
activated and running.

To configure the holiday (when you stay at home)

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [2.2]: 

 > Holiday > Holiday mode.

2

Select Home.

3

Configure the holiday mode settings (when you stay at home).

4

Activate the holiday mode.

Possible holiday mode settings (when you stay at home)

Setting

Description

From and Until

First and last day of your holiday.

Use day
schedule

Day schedule used during your holiday.

Example: 

Saturday

INFORMATION

Switch to Adv. end user if you want to change the Use day
schedule setting.

To configure the holiday (when you go away)

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [2.2]: 

 > Holiday > Holiday mode.

2

Select Leave.

3

Configure the holiday mode settings (when you go away).

4

Activate the holiday mode.

Possible holiday mode settings (when you go away)

Setting

Description

From and Until

First and last day of your holiday.

Operation mode Operation mode used during your holiday.

Heating

Set point used during your holiday when the unit
is operating in heating mode.

DHW

Turn ON or OFF domestic hot water operation
during your holiday.

INFORMATION

You  can  only  change  the  From  and  Until  settings  in  the
End  user  level.  For  changing  the  other  settings,  you  have
to switch to Adv. end user level.

To activate or deactivate the holiday mode

Prerequisite: 

You have configured the holiday.

1

Go to [2.1]: 

 > Holiday > Holiday.

2

Do one of the following:

▪ To activate, select Yes and press 

.

▪ To deactivate, select No and press 

.

Usage example: You go away during the winter

If you are in the following situation:

▪ In 2 days, you go away for 2 weeks during the winter.

▪ You want to save energy, but prevent your house from freezing.

Then you can do the following:

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Configure  the  holiday.  Go  to  [2]: 

  >  Holiday,  and  configure

the following settings:

Setting

Value

Holiday mode

Away

From

2 February 2014

Until

16 February 2014

Operation mode

Heating

Heating

12°C

2

Activate the holiday mode.

▪ Go to [2.1]: 

 > Holiday > Holiday.

▪ Select Yes and press 

.

Advantage:

▪ Before and after your holiday, your normal schedule will be used.

▪ During  your  holiday,  you  save  energy  and  prevent  your  house

from freezing.

Usage example: You come home during your holiday

If you are in the following situation:

▪ You configured and activated the holiday mode (Away).

▪ During your holiday, you come home for a few hours and want to

use your normal schedule.

Then you can do the following:

1

Deactivate the holiday mode.

2

When you go away again, activate the holiday mode again.

Advantage:

You do NOT have to change your schedule or holiday configuration.

4.6.4

Reading out information

To read out information

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [6]: 

 > Information.

Possible read-out information

In menu…

You can read out…

[6.1] Sensor information

Room, tank or DHW, outside,
and leaving water temperature.
(If applicable)

[6.2] Energy metering

Produced energy, consumed
electricity, and consumed gas.

[6.3] Error handling

Error history and contact/
helpdesk number.

[6.4] User permission level

Current user permission level.

[6.5] Actuators

Status/mode of each actuator.

Example: 

Domestic hot water

pump ON/OFF.

[6.6] Operation modes

Current operation mode.

Example: 

Defrost/oil return

mode.

[6.7] Running hours

Running hours of the system.

[6.8] Version

Version information about the
system.

Содержание Altherma EHVZ08S18CB

Страница 1: ...User reference guide Daikin Altherma Low temperature split English User reference guide Daikin Altherma Low temperature split EHVZ04S18CB EHVZ08S18CB EHVZ16S18CB...

Страница 2: ...ctions 15 4 7 Preset values and schedules 16 4 7 1 Using preset values 16 4 7 2 Using and programming schedules 16 4 7 3 Schedules Example 17 4 7 4 Predefined schedules Room temperature leaving water...

Страница 3: ...for reuse By ensuring waste batteries are disposed of correctly you will help to prevent potential negative consequences for the environment and human health 2 About this document Thank you for purch...

Страница 4: ...taller settings 4 2 The user interface at a glance 4 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home page Goes to the default home page when you are in the menu...

Страница 5: ...water temperature LWT add DHW tank temperature Tank To go to a home page 1 Press Result One of the home pages is displayed 2 Press again to display the next home page if any 4 3 2 Using the menu struc...

Страница 6: ...emperature 2 Check the following If Then the temperature control is Main zone Additional zone if any Room temperature is listed under 6 1 Information Sensor information Room thermostat control Go to n...

Страница 7: ...d temperature 22 0 C Desired temperature To temporarily overrule the room temperature schedule 1 Go to the room temperature home page Room 2 Use or to adjust the temperature To change the mode from sc...

Страница 8: ...mfort will be used until 02 00 After that the schedule will be used again Usage example You go away for a couple of hours If you are in the following situation You are using the following room tempera...

Страница 9: ...ess or to adjust overrule To adjust the leaving water temperature additional 1 Go to the additional leaving water temperature home page LWT add 2 Press or to adjust Example 45 C 47 C INFORMATION In ca...

Страница 10: ...temperature home page LWT add 2 Press or to adjust Example 45 C 47 C INFORMATION In case of weather dependency an offset value can be modified 4 5 Domestic hot water control 4 5 1 About domestic hot w...

Страница 11: ...in and the DHW tank temperature decreases again At 00 00 the next day the cycle repeats In scheduled mode you can do the following You can Location Read out the active or next scheduled desired temper...

Страница 12: ...ode About the DHW tank booster mode You can use the DHW tank booster mode to immediately start heating up the water to the preset value Storage comfort However this consumes extra energy To check if t...

Страница 13: ...F to ensure the heating capacity of the system However during the afternoon the baby is sleeping and you want it to be quiet Then you can do the following Prerequisite You switched the permission leve...

Страница 14: ...lect No and press Usage example You go away during the winter If you are in the following situation In 2 days you go away for 2 weeks during the winter You want to save energy but prevent your house f...

Страница 15: ...30 Actual temperature Room Scheduled Mon Tue To configure which home pages are made available to the end user Prerequisite You switched the permission level to Advanced end user 1 Go to 7 1 4 User set...

Страница 16: ...alue Eco preset value Custom temperature Main leaving water temperature Additional leaving water temperature Program when the additional leaving water temperature is turned ON and OFF Control Possible...

Страница 17: ...and press 2 Select User defined 1 User defined 2 or User defined 3 and press 3 Change the name and press Only applicable for room temperature schedules Example MyWeekSchedule To select which schedule...

Страница 18: ...Set weather dependent 2 For main leaving water temperature zone 7 7 1 modify with and confirm with 3 If applicable for additional leaving water temperature zone 7 7 2 modify with and confirm with Set...

Страница 19: ...Error handling User permission level Actuators Operation modes Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User...

Страница 20: ...the DHW tank booster mode is active the risk of space heating and capacity shortage comfort problems is significant In case of frequent domestic hot water operation frequent and long space heating in...

Страница 21: ...eck the warning history Prerequisite Only available if is displayed on the home pages 1 Go to 6 3 1 Information Error handling Warning history 7 4 Symptom You are feeling too cold hot in your living r...

Страница 22: ...et of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the product User Person who is owner of the product and or operat...

Страница 23: ......

Страница 24: ...4P401674 1 2015 02 Copyright 2015 Daikin...

Отзывы: