3 Operation

Operation manual

5

08S18+23DA
Daikin Altherma – Low temperature split
4P495247-1C – 2018.11

Item

Description

 User settings

Gives access to user settings such as
holiday mode and quiet mode.

 Information

Displays data and information about the
indoor unit.

 Installer settings

Restriction: 

Only for the installer.

Gives access to advanced settings.

 Commissioning

Restriction: 

Only for the installer.

Perform tests and maintenance.

 User profile

Change the active user profile.

 Operation

Turn heating functionality and domestic hot
water preparation on or off.

3.2.3

Setpoint screen

The  setpoint  screen  is  displayed  for  screens  describing  system
components that need a setpoint value.

Example:

▪ Room temperature screen

▪ Main zone screen

▪ Additional zone screen

▪ Tank temperature screen

a1

d

+

d

e

d

e

c

a2

b1

b2

Possible actions on this screen

Go through the list of the submenu.

Go to the submenu.

Adjust and automatically apply the desired
temperature.

Item

Description

Minimum temperature limit

a1

Fixed by the unit

a2

Restricted by the installer

Maximum temperature limit

b1

Fixed by the unit

b2

Restricted by the installer

Current temperature

c

Measured by the unit

Desired temperature

d

Turn the right dial to
increase/decrease.

Submenu

e

Turn or press the left dial to
go to the submenu.

3.2.4

Detailed screen with values

a

b

a

Settings

b

Values

Possible actions on this screen

Go through the list of settings.

Change the value.

Go to the next setting.

Possible actions on this screen

Confirm changes and proceed.

3.3

Space heating control

3.3.1

Setting the space operation mode

About space operation modes

This unit is a heating only model. The system can heat up a space,
but NOT cool down a space.

3.3.2

To change the desired room temperature

During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.

1

Go to [1]: Room.

You can read out the desired and actual room
temperature in the center of the setpoint screen.

2

Adjust the desired room temperature.

If scheduling is on after changing the desired room temperature

▪ The  temperature  will  stay  the  same  as  long  as  there  is  no

scheduled action.

▪ The  desired  room  temperature  will  return  to  its  scheduled  value

whenever a scheduled action occurs.

You  can  avoid  scheduled  behaviour  by  (temporarily)  turning  off
scheduling.

To turn off room temperature scheduling

1

Go to [1.1]: Room > Schedule.

2

Select No.

3.3.3

To change the desired leaving water
temperature

INFORMATION

The  leaving  water  is  the  water  that  is  sent  to  the  heat
emitters.  The  desired  leaving  water  temperature  is  set  by
your  installer  in  accordance  with  the  heat  emitter  type.
Only adjust the leaving water temperature settings in case
of problems.

You  can  use  the  leaving  water  temperature  setpoint  screen  to  read
out and adjust the desired leaving water temperature.

1

Go to [2]: Main zone or [3]: Additional zone.

You can read out the desired and actual leaving
water temperature in the center of the setpoint
screen.

2

Adjust the desired leaving water temperature.

3.4

Domestic hot water control

3.4.1

Reheat mode

In  reheat  mode  the  DHW  tank  continuously  heats  up  to  the
temperature shown on the home screen (example: 50°C).

Содержание Altherma EHVZ04S18DA6V

Страница 1: ...Operation manual Daikin Altherma Low temperature split English Operation manual Daikin Altherma Low temperature split EHVZ04S18DA6V G EHVZ08S18DA6V G EHVZ08S23DA6V G EHVZ08S18DA9W G EHVZ08S23DA9W G...

Страница 2: ...the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for futu...

Страница 3: ...he screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user permission level User or Advanced user 15 min Installer 1 h Dia...

Страница 4: ...ription Additional zone h3 h1 h2 h1 Heat emitter type Underfloor heating Fancoil unit Radiator h2 Leaving water temperature setpoint h3 Room thermostat type External control Hidden Leaving water tempe...

Страница 5: ...anges and proceed 3 3 Space heating control 3 3 1 Setting the space operation mode About space operation modes This unit is a heating only model The system can heat up a space but NOT cool down a spac...

Страница 6: ...the next scheduled action to heat up the domestic hot water tank Then you can activate powerful operation The domestic hot water tank will start heating up the water to the Comfort temperature INFORM...

Страница 7: ...You can program up to 6 actions each day 0 6 00 8 30 17 30 20 C 18 C 22 00 18 C 21 C 12 24 Mon 4 Confirm the changes To copy the schedule to the other weekdays 1 Select Monday Mon Sat Wed Fri Thu Tue...

Страница 8: ...n Sat Wed Fri Thu Tue Sun User defined 1 C To rename the schedule INFORMATION Not all schedules can be renamed 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Se...

Страница 9: ...ice C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electricity price High Medium Low Schedule 7 2 Time date Hours Minutes...

Страница 10: ...er periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a prese...

Страница 11: ...ature cannot be reached Increase the desired leaving water temperature in accordance with the heat emitter type 6 3 Symptom The water at the tap is too cold Possible cause Corrective action You ran ou...

Страница 12: ...rs or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you want to purge air is sufficiently venti...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...4P495247 1C 2018 11 Copyright 2017 Daikin 4P495247 1 C 00000003...

Отзывы: