14 Technical data
Installer reference guide
105
ERLQ004~008CA + EHVH/X04+08S18+26CB
Daikin Altherma – Low temperature split
4P384973-1A – 2016.02
Indoor units
EHVH04S18C
B3V
EHVH08S18C
B3V
EHVH08S26C
B9W
EHVX04S18C
B3V
EHVX08S18C
B3V
EHVX08S26C
B9W
Liquid side
Ø6.4 mm
Sound power level
Nominal
42 dBA
(4)
Sound pressure level
Nominal
28 dBA
(5)
Operation range
Heating
Heating at water
side
Maximally 55°C
Indoor installation
5~35°C DB
Domestic hot water
at water side
60°C
(6)
Safety devices
Thermal cut out
Electrical specifications
EHVH04S18C
B3V
EHVH08S18C
B3V
EHVH08S26C
B9W
EHVX04S18C
B3V
EHVX08S18C
B3V
EHVX08S26C
B9W
Power supply
Name
See
(7)
Voltage range
–10%~+10%
Wiring connections
For power supply
backup heater
Quantity of wires
3G
Refer to
installation
manual
3G
Refer to
installation
manual
Type of wires
See
(8)
Communication cable
to outdoor unit
Quantity of wires
3
Type of wires
2.5 mm
2
Preferential kWh rate
power supply
Quantity of wires
Power: 2
Type of wires
Power: 6.3 A
(8)
Electricity meter
Quantity of wires
2
Type of wires
Minimum 0.75 mm
2
(5 V DC pulse detection)
Domestic hot water
pump
Quantity of wires
2
Type of wires
Minimum 0.75 mm
2
(2 A in rush, 1 A continuous)
For connection with
R6T
Quantity of wires
2
Type of wires
Minimum 0.75 mm
2
For connection with
A3P
Quantity of wires
Depends on thermostat type
Type of wires
Voltage 230 V/maximum current: 100 mA/minimum 0.75 mm
2
.
(8)
For connection with
M2S
Quantity of wires
2
Type of wires
Voltage 230 V/maximum current: 100 mA/minimum 0.75 mm
2
.
(8)
For connection with
bottom plate heater
Quantity of wires
2
Type of wires
Voltage 230 V/maximum current: 100 mA/minimum 0.75 mm
2
.
(8)
For connection with
user interface
Quantity of wires
2
Type of wires
0.75 mm
2
~1.25 mm
2
(maximum length 500 m)
For connection with
optional FWXV
(demand input and
output)
Quantity of wires
4
Type of wires
100 mA, minimum 0.75 mm
2
(1)
PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC.
(2)
Operation area is extended to lower flow rates only in case the unit operated with heat pump only. (Not in startup, no backup heater operation, no
defrost operation).
(3)
Including PHE + backup heater; excluding expansion vessel.
(4)
DB/WB 7°C/6°C – LWC 35°C (DT=5°C)
(5)
The sound pressure level is measured in an anechoice room at 1 m distance from the unit. It is a relative value, depending on the distance and
acoustic environment. The sound pressure level mentioned is maximum possible value inside operation range of unit.
(6)
For ERLQ outdoor units >55°C backup heater only, no heat pump operation.
(7)
Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the
outdoor unit. The optional domestic hot water tank has a separate power supply.
(8)
Select diameter and type according to national and local regulations.