14 Technical data
Installer reference guide
103
ERLQ004~008CA + EHVH/X04+08S18+26CB
Daikin Altherma – Low temperature split
4P384973-1A – 2016.02
Outdoor units
ERLQ004CAV3
ERLQ006CAV3
ERLQ008CAV3
Drain
Quantity
2
Type
Hole
Diameter (OD)
1× Ø15 mm + 1× Ø20 mm
Piping length
Minimum
3 m
Maximum
30 m
Equivalent
—
Chargeless
10 m
Additional refrigerant charge
0.02 kg/m IF >10 m
Maximum height difference between outdoor unit and indoor unit
20 m
Defrost method
Reverse cycle
Defrost control
Sensor for outdoor heat exchanger temperature
Capacity control method
Inverter controlled
Electrical specifications
ERLQ004~008CAV3
Power supply
Name
V3
Phase
1
Frequency
50 Hz
Voltage
230 V
Voltage range
Minimum
–10%
Maximum
+10%
Current
Nominal running current
Cooling
—
Heating
Starting current
Cooling
15.7 A
15.9 A
3
Heating
Maximum running current
Cooling
15.7 A
15.9 A
3
Heating
Z
max
—
Recommended fuses
16 A
20 A
Wiring connections
For power supply
Quantity
3
Remark
—
For connection with indoor
Quantity
3
Remark
No earth wire
Figure A: Starting current
Daikin inverter controlled compressor starting current always less
then or equal to maximal running current.
A
B
D
E
C
A
Running current
B
Time
C
Maximum
D
Example 1
E
Example 2
Standard on/off compressor starting current to maximum running
current
A
B
D
E
C
A
Running current
B
Time
C
Maximum
D
Example 1
E
Example 2
(3)
See figure A.