8 Technical data
Installation manual
21
EBLQ+07CAV3
Daikin Altherma low temperature monobloc
4P403578-1F – 2018.06
8
Technical data
A
subset
of the latest technical data is available on the regional Daikin website (publicly accessible). The
full set
of latest technical data is
available on the Daikin extranet (authentication required).
8.1
Piping diagram: Outdoor unit
p
12.7 CuT
3D097222-1
R1T
t >
·15.9· CuT
12.7 CuT
12.7 CuT
12.7 CuT
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT
p >
R3T
t >
R1T
R3T
R4T
7.9 CuT
4.0 CuT
7.9 CuT
4.0 CuT
4.0 CuT
4.0 CuT
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT
1
4
3
2
t >
12.7 CuT
12.7 CuT
R4T
9.5 CuT
6.4 CuT
6.4 CuT
M
6.4 CuT
6.4 CuT
Discharge pipe thermistor
Accumulator
Compressor
High pressure switch
Muffler
Muffler
4-way valve
Pressure sensor
Refrigerant flow
Cooling
Heating
Liquid stop
valveV
Plate heat exchanger
Gas stop valve
with service port
Air purge
Flow sensor
Pump
Flow switch
Outlet
Shut-off valve with drain/fill valve
Expansion vessel
Safety valve
Blow-off
Filter
Inlet
Outlet water heat exchanger thermistor
Refrigerant liquid side thermistor
Inlet water thermistor
Outdoor air temperature thermistor
Heat exchanger
Capillary tube
Capillary tube
Capillary tube
Capillary tube
Heat exchanger thermistor
Propeller fan
Muffler with filter
Muffler with filter
Motor-operated valve
Shut-off valve with
drain/fill valve
Filter
Filter