3 About the system
Operation manual
4
EA23DA6V(7)+9W
Daikin Altherma 3 H F
4P556074-1A – 2021.09
WARNING
The refrigerant inside the unit is mildly
flammable, but normally does NOT
leak. If the refrigerant leaks in the room
and comes in contact with fire from a
burner, a heater, or a cooker, this may
result in fire, or the formation of a
harmful gas.
Turn off any combustible heating
devices, ventilate the room, and
contact the dealer where you
purchased the unit.
Do NOT use the unit until a service
person confirms that the part from
which the refrigerant leaked has been
repaired.
WARNING
Air purging heat emitters or
collectors.
Before you purge air from
heat emitters or collectors, check if
or
is displayed on the home screen
of the user interface.
▪ If not, you can purge air immediately.
▪ If yes, make sure that the room
where you want to purge air is
sufficiently ventilated.
Reason:
Refrigerant might leak into the water
circuit, and subsequently into the
room when you purge air from the
heat emitters or collectors.
3
About the system
Depending on the system layout, the system can:
▪ Heat up a space
▪ Cool down a space (if a heating/cooling heat pump model is
installed)
▪ Produce domestic hot water
INFORMATION
Cooling is only applicable in case a conversion kit
(EKHVCONV*) is installed.
3.1
Components in a typical system
layout
d
a
b c
e
f
g
B
C
A
A
Main zone.
Example:
Living room.
B
Additional zone.
Example:
Bedroom.
C
Technical room.
Example:
Garage.
a
Outdoor unit heat pump
b
Indoor unit heat pump
c
Domestic hot water (DHW) tank
d
User interface of the indoor unit
e
User interface used as room thermostat
f
Underfloor heating
g
Radiators, heat pump convectors, or fan coil units
4
Operation
INFORMATION
Cooling is only applicable in case a conversion kit
(EKHVCONV*) is installed.
4.1
User interface: Overview
The user interface has the following components:
a
b
c
a
Status indicator
b
LCD screen
c
Dials and buttons
Status indicator
The LEDs of the status indicator light up or blink to show the
operating mode of the unit.
LED
Mode
Description
Blinking blue
Standby
The unit is not in operation.
Continuous blue Operation
The unit is in operation.
Blinking red
Malfunction
A malfunction occurred.
See
for more information.
LCD screen
The LCD screen has a sleeping function. After 15 min of non-
interaction with the user interface, the screen darkens. Pressing any
button or rotating any dial awakens the display.