background image

4 Operation

Operation manual

13

EA23DA6V(7)+9W
Daikin Altherma 3 H F
4P556074-1A – 2021.09

4.8

Menu structure: Overview user settings

[1]

Room

Room sensor offset

Setpoint range

Antifrost

Cooling schedule

Heating schedule

Schedule

(*)

[2]

Main zone

Schedule
Heating schedule

Setpoint mode

Cooling schedule

Heating WD curve
Cooling WD curve

(*)

(*)

[3]

Additional zone

Schedule
Heating schedule

Setpoint mode

Cooling schedule

Heating WD curve
Cooling WD curve

(*)

(*)

[4]

Space heating/cooling

Operation mode
Operation mode schedule

(*)

[5]

Tank

Powerful operation
Comfort setpoint
Eco setpoint
Reheat setpoint
Schedule

[7]

User settings

Language
Time/date
Holiday
Quiet
Electricity price
Gas price

[8]

Information

Energy data

Malfunction history

Dealer information

Sensors
Actuators
Operation modes
About
Connection status

[B]

User profile

[C]

Operation

Room

Space heating/cooling

Tank

[1.4]

Antifrost

Activation
Room setpoint

[1.5]

Setpoint range

Heating minimum
Heating maximum
Cooling minimum
Cooling maximum

(*)
(*)

[7.2]

Time/date

Hours
Minutes
Year
Month
Day
Daylight savings time
Format

[7.3]

Holiday

Activation
From
Till

[7.4]

Quiet

Activation
Schedule

[7.5]

Electricity price

High
Medium
Low
Schedule

[8.1]

Energy data

Electricity input
Produced heat

Setpoint screen

(*)

Only applicable when EKHVCONV* is installed

INFORMATION

Depending on the selected installer settings and unit type,
settings will be visible/invisible.

Содержание Altherma EAVZ16S18DA6V

Страница 1: ...Operation manual Daikin Altherma 3 H F English Operation manual Daikin Altherma 3 H F EAVZ16S18DA6V 7 EAVZ16S23DA6V 7 EAVZ16S18DA9W EAVZ16S23DA9W...

Страница 2: ...filled in the installer settings tables If NOT request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation se...

Страница 3: ...oil and of other parts MUST be done by an authorised installer and MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery B...

Страница 4: ...ng cooling heat pump model is installed Produce domestic hot water INFORMATION Cooling is only applicable in case a conversion kit EKHVCONV is installed 3 1 Components in a typical system layout d a b...

Страница 5: ...side of the screen Turn the right dial Navigate through the possible values and settings Press the right dial Confirm your choice and go to the next menu item 4 2 Possible screens Overview The most c...

Страница 6: ...t Enter the submenu Enable disable breadcrumbs Submenu Description 0 or Malfunctioning Restriction Only displayed if a malfunction occurs See 7 1 To display the help text in case of a malfunction 415...

Страница 7: ...alue Go to the next setting Confirm changes and proceed 4 3 Turning operation ON or OFF 4 3 1 Visual indication Certain functionalities of the unit can be enabled or disabled separately If a functiona...

Страница 8: ...l it can both heat up and cool down a space You have to tell the system which operation mode to use To tell the system which space operation to use you can You can Location Check which space operation...

Страница 9: ...water corresponding to a schedule The best time to allow the tank to produce hot water is at night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2...

Страница 10: ...st of digits and change the selected digit Move the cursor from left to right Confirm the pin code and proceed User pin code The User pin code is 0000 0000 User Advanced user pin code The Advanced use...

Страница 11: ...programmed action In this example Monday is the first day you programmed Thus the last programmed action is valid up to the first action of next Monday To copy the schedule to the other weekdays 1 Se...

Страница 12: ...e Rename Select 3 optional To delete the current schedule name browse through the character list until is displayed then press to remove the previous character Repeat for each character of the schedul...

Страница 13: ...edule 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection s...

Страница 14: ...hours For longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs ONLY in scheduled mode Program to heat up the DHW t...

Страница 15: ...ture See 4 4 2 To change the desired room temperature 48 If the problem recurs daily do one of the following Increase decrease the room temperature preset value See the user reference guide Adjust the...

Страница 16: ...text in case of a malfunction 415 for more information about the malfunction a We recommend to purge air with the air purge function of the unit to be performed by the installer If you purge air from...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...4P556074 1A 2021 09 Copyright 2018 Daikin 4P556074 1 A 0000000 Verantwortung f r Energie und Umwelt...

Отзывы: