4 Installation
Installation manual
7
EHBH/X04+08DA
Daikin Altherma 3 R W
4P495266-1D – 2019.10
4
Installation
4.1
Opening the units
4.1.1
To open the indoor unit
Overview
1
2
3
1
4
4
1
Front panel
2
Switch box cover
3
Switch box
4
User interface panel
Open
1
Remove the front panel.
2
2
1
3
2
If you have to connect electrical wiring, remove the switch box
cover.
4×
3
If you have to do work behind the switch box, open the switch
box.
2×
1
2
4
If you have to do work behind the user interface panel or upload
new software into the user interface, open the user interface
panel.
1
2
3
2×
5
Optional: Remove the user interface panel.
NOTICE
If you remove the user interface panel, also disconnect the
cables from the back of the user interface panel to prevent
damage.
3
1
2
4.2
Mounting the indoor unit
4.2.1
To install the indoor unit
1
Fix the wall bracket (accessory) to the wall (level) with 2 Ø8 mm
bolts.