9
|
Configuration
Installer reference guide
185
EPRA14~W1 + ETBH/9W
Daikin Altherma 3 H HT W
4P587501-1A – 2020.01
#
Code
Description
9.4.4
[4-03]
▪
4: Booster heater operation is NOT allowed
except for "Disinfection function".
Only use this in case the capacity of the
heat pump can cover the heating requirements
of the house and domestic hot water over the
complete heating season.
The booster heater will not be allowed to
operate when T
a
<[5‑03] and [5‑02]=1. The
domestic hot water temperature can be
maximum the heat pump OFF temperature.
Emergency
Emergency
When the heat pump fails to operate, the backup heater and/or booster heater
can serve as an emergency heater. It then takes over the heat load either
automatically or by manual interaction.
▪
When
Emergency
is set to
Automatic
and a heat pump failure occurs, the
backup heater automatically takes over the heat load, and the booster heater in
the optional tank takes over the domestic hot water production.
▪
When
Emergency
is set to
Manual
and a heat pump failure occurs, the
domestic hot water heating and space heating stops.
To manually recover it via the user interface, go to the
Malfunctioning
main
menu screen and confirm whether the backup heater and/or booster heater can
take over the heat load or not.
▪
Alternatively, when
Emergency
is set to:
-
auto SH reduced/DHW on
, space heating is reduced but domestic hot
water is still available.
-
auto SH reduced/DHW off
, space heating is reduced and domestic hot
water is NOT available.
-
auto SH normal/DHW off
, space heating operates as normally but
domestic hot water is NOT available.
Similarly as in
Manual
mode, the unit can take the full load with the backup
heater and/or booster heater if the user activates this via the
Malfunctioning
main menu screen.
To keep energy consumption low, we recommend to set
Emergency
to
auto SH
reduced/DHW off
if the house is unattended for longer periods.
#
Code
Description
[9.5.1]
[4-06]
▪
0:
Manual
▪
1:
Automatic
▪
2:
auto SH reduced/DHW on
▪
3:
auto SH reduced/DHW off
▪
4:
auto SH normal/DHW off
INFORMATION
The auto emergency setting can be set in the menu structure of the user interface
only.