background image

Operation manual

Daikin Altherma 3 H F+W

English

Operation manual

Daikin Altherma 3 H F+W

EABH16D▲6V▼
EABH16D▲9W▼
EABX16D▲6V▼
EABX16D▲9W▼

EAVH16S18D▲6V▼
EAVH16S23D▲6V▼
EAVH16S18D▲9W▼
EAVH16S23D▲9W▼
EAVX16S18D▲6V▼
EAVX16S23D▲6V▼
EAVX16S18D▲9W▼
EAVX16S23D▲9W▼

EAVH16SU18D▲6V▼
EAVH16SU23D▲6V▼

▲= A, B, C, …, Z
▼= , , 1, 2, 3, …, 9

Содержание Altherma 3 H F EABH16D 6V Series

Страница 1: ...ish Operation manual Daikin Altherma 3 H F W EABH16D 6V EABH16D 9W EABX16D 6V EABX16D 9W EAVH16S18D 6V EAVH16S23D 6V EAVH16S18D 9W EAVH16S23D 9W EAVX16S18D 6V EAVX16S23D 6V EAVX16S18D 9W EAVX16S23D 9W EAVH16SU18D 6V EAVH16SU23D 6V A B C Z 1 2 3 9 ...

Страница 2: ...he has filled in the installer settings tables If NOT request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of General safety precautions Safety instructions that you must read before installing Format Paper in the box of the indoor unit Operation manual Quick guide for bas...

Страница 3: ...nt of oil and of other parts MUST be done by an authorised installer and MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery By ensuring this product is disposed of correctly you will help to prevent potential negative consequences for the environment and human health For more information contact your installer or local...

Страница 4: ...stem layout the system can Heat up a space Cool down a space if a heating cooling heat pump model is installed Produce domestic hot water if a DHW tank is installed INFORMATION Cooling is only applicable in case of reversible models 3 1 Components in a typical system layout d a b c e f g B C A A Main zone Example Living room B Additional zone Example Bedroom C Technical room Example Garage a Outdo...

Страница 5: ... e Right dial The LCD shows an arc on the right side of the display when you can use the right dial Turn then press the right dial Change a value or setting shown at the right side of the screen Turn the right dial Navigate through the possible values and settings Press the right dial Confirm your choice and go to the next menu item 4 2 Possible screens Overview The most common screens are as foll...

Страница 6: ...ting cooling a Selected submenu Possible actions on this screen Go through the list Enter the submenu Enable disable breadcrumbs Submenu Description 0 or Malfunctioning Restriction Only displayed if a malfunction occurs See 7 1 To display the help text in case of a malfunction 415 for more information 1 Room Restriction Only displayed if a room thermostat is connected to the indoor unit Set the ro...

Страница 7: ...ed screen with values Example a b c a b c 7 2 1 Time date Hours 11 30 Minutes a Settings b Values c Selected setting and value Possible actions on this screen Go through the list of settings Change the value Go to the next setting Confirm changes and proceed 4 3 Turning operation ON or OFF 4 3 1 Visual indication Certain functionalities of the unit can be enabled or disabled separately If a functi...

Страница 8: ...o use To tell the system which space operation to use you can You can Location Check which space operation mode is currently used Home screen Set the space operation mode permanently Main menu Restrict automatic changeover according to a monthly schedule To set the space operation mode 1 Go to 4 1 Space heating cooling Operation mode 2 Select one of the following options Heating Only heating mode ...

Страница 9: ...eat only INFORMATION When the DHW tank mode is reheat the risk for capacity shortage and comfort problem is significant In case of frequent reheat operation space heating cooling function is regularly interrupted 4 5 2 Scheduled mode In scheduled mode the DHW tank produces hot water corresponding to a schedule The best time to allow the tank to produce hot water is at night because the space heati...

Страница 10: ...nd edit more information To change the user permission level You can change the user permission level as follows 1 Go to B User profile 2 Enter the applicable pin code for the user permission level Browse through the list of digits and change the selected digit Move the cursor from left to right Confirm the pin code and proceed User pin code The User pin code is 0000 0000 User Advanced user pin co...

Страница 11: ...on 4 Confirm the changes Result The schedule for Monday is defined The value of the last action is valid until the next programmed action In this example Monday is the first day you programmed Thus the last programmed action is valid up to the first action of next Monday To copy the schedule to the other weekdays 1 Select Monday Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Copy Delete Edit ...

Страница 12: ...un User defined 1 2 Select Rename Delete Rename Select 3 optional To delete the current schedule name browse through the character list until is displayed then press to remove the previous character Repeat for each character of the schedule name 4 To name the current schedule browse through the character list and confirm the selected character The schedule name can contain up to 15 characters 5 Co...

Страница 13: ...hedule 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status B User profile C Operation Room Space heating cooling Tank 1 4 Antifrost Activation Room setpoint 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time dat...

Страница 14: ...heduled room temperature until the next scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs ONLY in scheduled mode Program to heat up the DHW tank to a preset value Comfort higher DHW tank temperature during the nigh...

Страница 15: ...ptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See 4 4 2 To change the desired room temperature 48 If the problem recurs daily do one of the following Increase decrease the room temperature preset value See the user reference guide Adjust the room temperature schedule...

Страница 16: ...ulic balancing is not sufficient change the pump limitation settings 9 0D and 9 0E if applicable Various malfunctions Check if or is displayed on the home screen of the user interface See 7 1 To display the help text in case of a malfunction 415 for more information about the malfunction a We recommend to purge air with the air purge function of the unit to be performed by the installer If you pur...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...4P644480 1C 2022 03 Copyright 2018 Daikin 4P644480 1 C 0000000 Verantwortung für Energie und Umwelt ...