background image

2 About the system

Operation manual

3

EGSAH/X06+10DA9W(G)
Daikin Altherma 3 GEO
4P569812-1 – 2019.02

1

Starting from the home screen, turn the left dial and
go to 

Space heating/cooling

.

4

Space heating/cooling

2

Press the left dial to enter the submenu.

3

Turn the left dial and go to 

Operation range

.

Operation range

4.3

4

Press the left dial to enter the submenu.

2

About the system

Depending on the system layout, the system can:

▪ Heat up a space

▪ Cool  down  a  space  (if  a  heating/cooling  heat  pump  model  is

installed)

▪ Produce domestic hot water

2.1

Components in a typical system
layout

g

A

d

b

a

f

e

c

B

C

A

Main zone. 

Example: 

Living room.

B

Additional zone. 

Example: 

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Brine loop

b

Indoor unit heat pump

c

Domestic hot water (DHW) tank

d

User interface at the indoor unit

e

Dedicated Human Comfort Interface (BRC1HHDA used as room
thermostat)

f

Underfloor heating

g

Radiators, heat pump convectors, or fan coil units

3

Operation

3.1

User interface: Overview

The user interface has the following components:

a

b
c

a

Status indicator

b

LCD screen

c

Dials and buttons

Status indicator

The  LEDs  of  the  status  indicator  light  up  or  blink  to  show  the
operating mode of the unit.

LED

Mode

Description

Blinking blue

Standby

The unit is not in operation.

Continuous blue Operation

The unit is in operation.

Blinking red

Malfunction

A malfunction occurred.

See 

"6.1 To display the help text

in case of a malfunction" on
page 11

 for more information.

LCD screen

The LCD screen has a sleeping function. After a certain time of non-
interaction with the user interface, the screen darkens. Pressing any
button  or  rotating  any  dial  awakens  the  display.  The  time  of  non-
interaction differs depending on the user permission level:

User

 or 

Advanced user

: 15 min

Installer

: 1 h

Dials and buttons

You use the dials and buttons:

▪ To navigate through the screens, menus and settings of the LCD

screen

▪ To set values

a

b

c

d

e

Item

Description

a

Left dial

The LCD shows an arc on the left side of the
display when you can use the left dial.

: Turn, then press the left dial. Navigate

through the menu structure.

: Turn the left dial. Choose a menu item.

: Press the left dial. Confirm your choice

or go to a submenu.

b

Back button

: Press to go back 1 step in the menu structure.

c

Home
button

: Press to go back to the home screen.

Содержание Altherma 3 GEO EGSAH10DA9W

Страница 1: ...Operation manual Daikin Altherma 3 GEO English Operation manual Daikin Altherma 3 GEO EGSAH06DA9W EGSAH10DA9W EGSAX06DA9W G EGSAX10DA9W G...

Страница 2: ...ep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of General safety precautions Safety instru...

Страница 3: ...cator b LCD screen c Dials and buttons Status indicator The LEDs of the status indicator light up or blink to show the operating mode of the unit LED Mode Description Blinking blue Standby The unit is...

Страница 4: ...Measured tank temperature 1 b Current date and time c Disinfection Powerful Disinfection mode active Powerful operation mode active d Space operation mode Cooling Heating e Outdoor quiet mode e1 6 Me...

Страница 5: ...e or cooling mode Tank Set the domestic hot water tank temperature User settings Gives access to user settings such as holiday mode and quiet mode Information Displays data and information about the i...

Страница 6: ...temperature is set by your installer in accordance with the heat emitter type Only adjust the leaving water temperature settings in case of problems You can use the leaving water temperature setpoint...

Страница 7: ...itional menu items for the user are now visible 3 6 Schedule screen Example This example shows how to set a room temperature schedule in heating mode for the main zone INFORMATION The procedures to pr...

Страница 8: ...e Sun User defined 1 C 4 Select Paste Delete Edit Copy Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C 5 Repeat this action for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined 1...

Страница 9: ...Operation mode Operation mode schedule 5 Tank Powerful operation Comfort setpoint Eco setpoint Reheat setpoint Schedule WD curve type 7 User settings Language Time date Holiday Quiet Electricity pric...

Страница 10: ...Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Example When you stay at home during your holiday or when you go away durin...

Страница 11: ...6 Possible cause Corrective action The weather dependent curve is set incorrectly Adjust the weather dependent curve See the user reference guide 6 3 Symptom The water at the tap is too cold Possible...