50
©
2014
Daikin
North
America,
LLC
Blower
Speed
Adjust
for
Multi
Speed
ECM
Blower
Airflow
Table
from
Manual
IOD
‐
2011A
(2
Stage
Heat,
Multi
‐
Speed
ECM)
Dip
Switch
Setting
DM96VE0302B
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
Rise
CFM
Rise
CFM
Rise
CFM
Rise
CFM
Rise
CFM
CFM
CFM
Fac
tor
y
Set
ti
ng
All
DIP
Switch
Positions
G
870
658
548
469
413
349
293
N/A
W1
870
21
658
28
548
34
469
40
413
45
349
293
N/A
W2
885
30
821
32
755
35
684
39
621
43
557
508
461
1
2
3
OFF
OFF OFF
Ylo
874
697
612
533
470
414
361
303
Y
1146
1097
1049
1002
941
895
846
787
ON
OFF OFF
Ylo
874
697
612
533
470
414
361
303
Y
921
868
810
743
670
614
560
505
ON
ON OFF
Ylo
928
868
810
743
670
614
560
505
Y
1146
1097
1049
1002
941
895
846
787
OFF
ON
OFF
Ylo
928
868
810
743
670
614
560
505
Y
870
658
548
469
413
349
293
N/A
OFF
OFF ON
Ylo
928
868
810
743
670
614
560
505
Y
885
821
755
684
621
557
508
461
OFF
ON
ON
Ylo
874
697
612
533
470
414
361
303
Y
1146
1097
1049
1002
941
895
846
787
ON
OFF
ON
Ylo
885
821
755
684
621
557
508
461
Y
1146
1097
1049
1002
941
895
846
787
ON
ON ON
Ylo
885
821
755
684
621
557
508
461
Y
874
697
612
532
470
414
361
303
©
2014
Daikin
North
America,
LLC
Setting
Multi
Speed
ECM
Blower
Switches
OFF
ON
1
2
3
“Multi
‐
Speed”
blower
speeds
are
adjusted
in
the
1
st
,
2
nd
,
and
3rd
dip
switches
in
“Switch
Bank:
S2”
represent
the
cooling
airflow
setting
.
Review
the
chart
in
the
prior
slide
that
represents
multi
speed
ECM
blowers
for
furnace
model
DM96VE0302B.
In
the
high
cooling
“Y”
factory
setting
,
switch
1,
2,
and
3
are
in
the
“OFF”
position.
(to
the
left)
Switch
Bank:
S2
Cooling
Airflow
DIP
Switch
No.
1
2
3
Y*
OFF
OFF
OFF
Ylo*
OFF
OFF
OFF
*Indicates
factory
setting
S2