Compressor
Si121292EC
20
Removal Procedure
2
Disconnect the
compressor lead wires.
3
Remove the overload
protector.
4
Heat up the brazed part
of the discharge side
pipe (a) and withdraw
the piping.
Some models have 3 nuts.
5
Heat up the brazed part
of the suction side pipe
(b) and withdraw the
piping.
6
Remove the 2 nuts.
7
Remove the
compressor.
Step
Procedure
Points
(R9471)
W(blue)
U(red)
Overload
protector
V(yellow)
(R13197)
(a)
(b)
(R10440)