background image

Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global_ac/

All rights reserved

c

Warning

z

Daikin products are manufactured for export to numerous countries throughout the world. Prior to 
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this 
product conforms to the applicable standards, and is suitable for use, in the region where the product 
will be used. This statement does not purport to exclude, restrict or modify the application of any local 
legislation.

z

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. 
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

z

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or 
contractor to install those parts and accessories. Use of unauthorised parts and accessories or 
improper installation of parts and accessories can result in water or refrigerant leakage, electrical 
shock, fire or explosion.

z

Read the User's Manual carefully before using this product. The User's Manual provides important 
safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install 

the outdoor unit close to the sea shore, contact your local distributor.

Dealer

z

Specifications, designs and other content appearing in this brochure are current as of July 2013 but subject to change without notice.

Si00-771

07/2013 AK.B

Содержание RKS25F2V1B

Страница 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Outdoor Unit Inverter Pair Type 2 5 3 5 kW Class Si00 771...

Страница 2: ...Service Manual Removal Procedure Outdoor Unit zCooling Only zHeat Pump RKS25F2V1B RXD25FAV2C RKS35F2V1B RXD35FAV2C RXD25FV2C RXD35FV2C RXS25F2V1B RXS35F2V1B RXS25FV2C RXS35FV2C...

Страница 3: ...lectrical Box 10 3 Removal of PCB 13 4 Removal of Reactor Partition Plate 15 5 Removal of Sound Blankets 16 6 Removal of Four Way Valve 17 7 Removal of Compressor 19 Note The illustrations may be slig...

Страница 4: ...sembling work Step Procedure Points 1 Appearance features Take care not to cut your finger by the fins of the outdoor heat exchanger 2 Remove the panels The stop valve cover is united with the shield...

Страница 5: ...ure 3 2 Remove the 3 screws and lift the top panel 3 Remove the drip proof plate 4 Remove the 4 screws and remove the discharge grille The discharge grille has 4 hooks Step Procedure Points Top panel...

Страница 6: ...e the 8 screws of the front panel 6 Unfasten the hooks Pull and remove the front panel The front panel has 4 hooks 3 Remove the fan motor Nut size M6 1 Remove the nut of the outdoor fan Step Procedure...

Страница 7: ...n When reassembling align the mark of the outdoor fan with the D cut section of the motor shaft 3 Cut the clamp 4 Disconnect the connector for the fan motor S70 5 Release the fan motor lead wire from...

Страница 8: ...s Fan Motor Si00 771 6 Removal Procedure 6 Remove the screw and remove the fan motor fixing frame When reassembling fit the lower hooks into the bottom frame Step Procedure Points R17052 Fan motor fix...

Страница 9: ...en reassembling put the fan motor lead wire through the back of the fan motor so as not to be entangled with the outdoor fan 8 Remove the 4 screws and remove the fan motor 4 Remove the right side pane...

Страница 10: ...Removal Procedure 2 Release the outdoor temperature thermistor 3 Lift up the guard net and remove it 4 Remove the 4 screws on the right side panel Step Procedure Points R7208 Outdoor temperature therm...

Страница 11: ...9 5 Remove the screw near the stop valves 6 Unfasten the hook on the rear side When reassembling make sure to fit the hook 7 Lift up the right side panel and remove it When reassembling make sure to...

Страница 12: ...Step Procedure Points 1 Disconnect the 2 connectors for the reactor Preparation Remove the outer panels and disconnect the connector for the fan motor according to the Removal of Outer Panels Fan Mot...

Страница 13: ...ssembling connect the connectors in the following order 1 S80 2 S20 3 S40 4 S30 5 reactor 6 Disconnect the connector for the four way valve coil S80 The cooling only models do not have the harness for...

Страница 14: ...8 Cut the clamp 9 Pull out the outdoor heat exchanger thermistor Be careful not to lose the clip for the thermistor 10 Lift and remove the electrical box Step Procedure Points R16471 R16472 Outdoor he...

Страница 15: ...wer supplies before disassembling work Step Procedure Points 1 Feature of the main PCB You can remove the main PCB when you disconnect the lead wires on the terminal board without removing the electri...

Страница 16: ...fasten the 3 hooks on the upper side Lift and pull out the main PCB S20 electronic expansion valve coil S30 compressor S40 overload protector S70 fan motor S80 four way valve coil S90 thermistors Step...

Страница 17: ...r Preparation Remove the outer panels according to the Removal of Outer Panels Fan Motor Remove the electrical box according to the Removal of Electrical Box 1 Remove the screw and remove the reactor...

Страница 18: ...blanket outer Preparation Remove the outer panels according to the Removal of Outer Panels Fan Motor Remove the electrical box according to the Removal of Electrical Box 2 Lift and remove the sound bl...

Страница 19: ...ssembling work Step Procedure Points 1 Pull out the electronic expansion valve coil 2 Remove the terminal cover 3 Disconnect the lead wires of the compressor 4 Remove the screw and remove the four way...

Страница 20: ...s affected by heat Keep below 120 C For the sake of this wrap the four way valve with wet cloth and provide water so that the cloth does not dry In case of difficulty with gas brazing machine 1 Discon...

Страница 21: ...protection do not discharge the refrigerant gas in the atmosphere Make sure to collect all the refrigerant gas Cautions for restoration 1 Restore the piping by non oxidation brazing 2 It is required t...

Страница 22: ...circuit When withdrawing the pipes be careful not to pinch them firmly with pliers The pipes may get deformed Provide a protective sheet or a steel plate so that the brazing flame cannot influence pe...

Страница 23: ...Revision History Month Year Version Revised contents 07 2013 Si00 771 First edition...

Страница 24: ...ories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acc...

Отзывы: