Si00-771
Removal of Four Way Valve
Removal Procedure
17
6. Removal of Four Way Valve
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Pull out the electronic
expansion valve coil.
2
Remove the terminal
cover.
3
Disconnect the lead
wires of the
compressor.
4
Remove the screw and
remove the four way
valve coil.
The cooling only models do
not have a four way valve
coil.
Electronic
expansion
valve coil
(R7233)
Terminal cover
(R7234)
V
W
U
Red (U)
Yellow (V)
Blue (W)
(R7235)
Four way valve coil
(R7247)