background image

Q-208-081 

 

 
 
2.2 Measurement parameter 

Measurement 

parameter 

Measuring range (

Class 
index 

Operation method  

Note 

Current 

[ A ] 

Rating 5A 

0~5A 

0.5 

(

Effective-value 
arithmetic  

Average value of each phase 
current (R, S, T)   (

Rating 1A 

0~1A 

Voltage 

[ V ] 

 

0~150V     (3φ3W) 
0~150/√3V  (3φ4W) 

0.5 

(

Fundamental-wave 
effective-value 
arithmetic  

3φ3W:Average value of each 

line voltage 
(RS,ST,TR)     (

3φ4W:The average value of 

each phase voltage  

       (RN,SN,TN)   

Active power 

[ W ] 

Rating 5A 

(1) 0~1000W 
(2) 0~833.3W 
(3) 0~750W 
(4) 0~500W 
(5) -1000~+1000W 
(6) -833.3~+833.3W 
(7) -750~+750W 
(8) -500~+500W 

0.5 

(

Time division 
multiplication  

It can alter into the 
measuring range of (1)~(8) 
with front DIP switch.  

Rating 1A 

(1) 0~200W 
(2) 0~166.7W 
(3) 0~150W 
(4) 0~100W 
(5) -200~+200W 
(6) -166.7~+166.7W 
(7) -150~+150W 
(8) -100~+100W 

Reactive 

power 

[ var ] 

Rating 5A 

(1) LEAD 1000~LAG 1000var 
(2) LEAD 833.3~LAG 833.3var 
(3) LEAD 750~ LAG 750var 
(4) LEAD 500~ LAG 500var 

0.5 

(

Time division 
multiplication  

It can alter into the 
measuring range of (1)~(4) 
with front DIP switch.  

Rating 1A 

(1) LEAD 200~LAG 200var 
(2) LEAD 166.7~LAG 166.7var 
(3) LEAD 150~ LAG 150var 
(4) LEAD 100~ LAG 100var 

Frequency 

[ Hz ] 

(1) 45~55Hz 
(2) 55~65Hz 
(3) 45~65Hz 

0.5 

(

Zero cross cycle 
arithmetic  

Voltage V(RS) or V(RN) is 
measured.  
It can alter into the 
measuring range of (1)~(3) 
with front DIP switch.  

 

About measurement  
(1)

 

A class index is a rated-frequency 50/60Hz ±10% value.  Linearity is within ±0.3%. 

(2)

 

In ±10% of rated frequencies, current, voltage, power, and reactive power are normally measured, in case 
the voltage between input lines is 10V or more.  If the voltage between input lines is 60V or more, it is 
measurable to the frequency of 168Hz. (However, outside of an accuracy guarantee) 

 

(3)

 

In case the voltage between input lines is 30V or more, frequency is measured normally.  

 
Note(

) The critical value of measuring range constitutes the following.  

  Current:0~120% of measuring range  
  Voltage:0~156V(3-phase 3-wire),0~156/√3V(3-phase 4-wire) 
          [Measures to +30% at the 120V(120/√3V) cases of rating] 
  Active power (One-side swing):-20~+120% of measuring range, 
  Active power (Both swing),Reactive power:-120~+120% of measuring range. 

 
Note(

) In case current, power, and reactive power measure the next inverter output directly, an error becomes 

large.  Cycle control, SCR phase angle control, PWM control. 

 
Note(

) S phase current of 3-phase 3-wire is for 2CT input, calculates in R phase and T phase current combination.  

And, TR line voltage is for 2VT input, calculates in RS and ST line voltage combination.  

 

Содержание HSQT2-93A

Страница 1: ...Q 208 081 INSTRUCTION MANUAL HIGH SPEED MULTI POWER LINE TRANSDUCER HSQT2 93A...

Страница 2: ...ammables combustible chemicals gas to prevent fire Connect specified power supply Connecting power supply beyond specification causes fire product failure When dust is on the terminal wipe it off afte...

Страница 3: ...8 3 Handling explanation 3 1 Outline dimension 9 3 2 Mounting instruction 9 3 3 The example of combination mounting dimension 9 3 4 Installation and removal to a rail 10 3 5 Connection 11 3 6 Handlin...

Страница 4: ...measurement range selection change The response time is high speed Current Voltage Active power Reactive power Less than input 1 cycle 10ms 99 Frequency Less than 1 second 99 As an option hydrogen su...

Страница 5: ...4 DC0 10V Over 2k 5 DC1 5V Over 600 8 DC 5V Over 600 9 DC 10V Over 2k B DC4 20mA Below 550 Auxiliary supply specification Mark Auxiliary supply 1 AC85 253V 50 60Hz Rated voltage 100 110V 200 220V DC8...

Страница 6: ...5Hz 0 5 Zero cross cycle arithmetic Voltage V RS or V RN is measured It can alter into the measuring range of 1 3 with front DIP switch About measurement 1 A class index is a rated frequency 50 60Hz 1...

Страница 7: ...ss index Update time of measured value 5ms Response time Time within 1 of final constant value when step input is charge A V W var With no moving average Less than input one cycle 10ms 2 times of movi...

Страница 8: ...and it applies for 5 minutes within 10 of errors Auxiliary supply circuit Voltage circuit Normal Common Over 1 5kV Current circuit Common Over 1 5kV Analog output Induction Over 1 0kV 3 Electromagnet...

Страница 9: ...ated electromagnetic field Frequency Field strength During test Output variation 20 After test Output variation 0 5 EN61000 6 2 2005 EN61000 4 3 2006 80 1000MHz 10V m 80 AM 1kHz 1 4 2 0GHz 3V m 80 AM...

Страница 10: ...ew mounting In screw mounting please install with M4 screw or M5 screw However the screw is not attached The tightening torque of a screw M4 1 0 1 3 N m M5 2 0 2 5N m Please detach an interval lining...

Страница 11: ...n in a BOX bottom is inserted in a rail Next if it pushes against the lower side arrow it is fixed with a lower slider Removal from a rail A minus screwdriver is inserted in the square socket of a sli...

Страница 12: ...is product should perform the right usage with careful attention to the following item 1 Please check that the voltage of power supply and the input signal to supply match the specification of this pr...

Страница 13: ...utput V V 5 2 5 10 5 0 0 1 0 1 kW LEAD 1 0 LAG 1 kvar AC input DC output V mA 3 12 5 20 1 4 0 0 5 1 kW 1 0 1 kW LEAD 1 0 LAG 1 kvar AC input DC output 3 Frequency Input Output Input Output Input Outpu...

Страница 14: ...frequency can be altered with a front DIP switch DIP switch ON 1 OFF 0 S12 S11 S10 S9 S8 S7 S6 S5 S4 S3 S2 S1 W measurement range var measurement range S1 S2 S3 Input 110V 5A is 1A rating S4 S5 Input...

Страница 15: ...continuing pushing a switch a coarse adjustment becomes possible DOWN setting for output adjustable DOWN This switch drops the output for the selected target for adjustment By pushing a short time swi...

Страница 16: ...13 Hitotsuya 1 chome Adachi ku Tokyo 121 8639 Japan Phone 03 3885 2411 Fax 03 3858 3966 Kyoto Office 1 19 Ichinobe Nishikawahara Jyoyou shi Kyoto 610 0114 Japan Phone 0774 55 1391 Fax 0774 54 1353 Re...

Отзывы: