background image

Q-222-031 

 

 
 

 

Countermeasures against troubles 

If trouble occurs within the warranty period, DAIICHI ELECTRONICS will repairs this product. 

 

 

Disposal 

Please dispose this product as industrial waste (non-combustible). 
Mercury parts and a nickel-cadmium battery are not used for this product. 

 

 

Warranty period 

The warranty period of the product is one year after the date of delivery. 

 

 

Warranty scope 

In the case that a defect is found in our product during the warranty period due to our responsibility, 
we will replace the defective part and repair. 
However, we will not be liable if the faults or defects are under any of the following items. 

 When the faults or defects are resulted from the modification or repair carried out by any other entity 

than our company. 

 Failure caused by violating various conditions regarding use, storage, etc. specified by the supplier. 

 When the faults or defects are caused by a reason not belongs to purchased or delivered products. 

 Damage or malfunction due to relocation or other transportation, movement or dropping. 

 In case that the faults or defects are resulted from force majeure such as fire or abnormal voltage  

and natural calamity or disaster. 

Our company shall not be liable for compensation of damages caused by any reason which is not our 
responsibility, loss opportunity, loss profits incurred to the user, special damages and consequential 
damages whether foreseeable or not, or damages not relating to our products. 

 

 

Replacement cycle of the product  

We recommend updating the product for 10 years as a rough standard. 

 

 

Change of instruction manual written contents 

This instruction manual changes written contents without a notice by product improvement etc. 

 

Содержание FWVTT2-92A-33

Страница 1: ...Q 222 031 INSTRUCTION MANUAL POWER FLOW THREE PHASE REACTIVE POWER TRANSDUCER FWVTT2 92A 33...

Страница 2: ...ase do not install in the place where sunlight hits directly Discoloration and degradation of a name plate and deformation of the case by the surface temperature rise may occur If the average daily te...

Страница 3: ...our company Failure caused by violating various conditions regarding use storage etc specified by the supplier When the faults or defects are caused by a reason not belongs to purchased or delivered p...

Страница 4: ...thod 4 5 Connection 6 6 Handling explanation 7 7 Specification 7 1 Rating 8 7 2 Performance 8 7 3 Electrical strength Mechanical strength 9 7 4 Noise immunity 9 7 5 EMC 10 7 6 Structure and environmen...

Страница 5: ...with a width of 35mm The terminal cover is standard equipment 3 Bundled items Inspection certificate 1 Packed in an envelope Terminal screw in a bag M4 screw 5 piece set 1 M4 screw 7 piece set 1 4 Mo...

Страница 6: ...this product from the IEC DIN rail Please insert a flathead screwdriver in the hole where a slider is square Next a slider is lowered in the direction of an arrow This product can be removed from the...

Страница 7: ...orque 1 0 to 1 3 N m Connection diagram AUX SUPPLY P1 1S 3 1 2 S1 1L 3S S2 P2 OUTPUT A B 3L P3 E LOAD Grounding is class D grounding grounding resistance 100 or less If there is a power line that caus...

Страница 8: ...be burdened Especially for voltage output products do not short circuit the output This product will not be damaged even if the output terminal is left open in the current output specifications Howev...

Страница 9: ...ess 5 3ms DC48V 3 1A or less 5 3ms Note Refer to the specification code for other ratings 7 2 Performance Item Specification Class index 0 5 Response time 1 second or less Ripple 1 p p or less Fluctua...

Страница 10: ...ond of rated voltage 10 times 10 second intervals 40 times 1 second and 20 times 4 seconds and 10 times 16 seconds of rated current 2 times 1 minute intervals 10 times 1 second of rated current 5 time...

Страница 11: ...61000 4 6 Power frequency magnetic field immunity test Frequency 50 60Hz Field strength 30A m Performance standard A During testing Within 20 error After test Within inherent error EN61000 6 2 EN61000...

Страница 12: ...its 10 to 55 5 to 90 RH Non condensing Storage temperature limits 40 to 70 Product warranty period One year period 7 7 Technical standards Item Specification Transducer JIS C 1111 2019 IEC 60688 2012...

Страница 13: ...g term use please adjust in the next way Remove the terminal cover and VR cap before adjustment and attach the VR cap and terminal cover after adjustment 1 For the output load connect an actual load w...

Страница 14: ...D 400 to 0 to LAG 400var Z Other Z Other Rated current Output Output load range Auxiliary supply 1 AC1A 2 Power transmission DC0 to 0 5 to 1V 200 or more AC80 to 264V Z Other Power receiving DC0 to 0...

Страница 15: ...t Output load range Auxiliary supply 2 AC5A 2 Power transmission DC0 to 0 5 to 1V 200 or more AC80 to 264V Z Other Power receiving DC0 to 0 5 to 1V F DC80 to 264V 3 Power transmission DC0 to 2 5 to 5V...

Страница 16: ...oad range Auxiliary supply 1 AC1A 2 Power transmission DC0 to 0 25 to 0 5V 200 or more AC80 to 264V Z Other Power receiving DC0 5 to 0 75 to 1V F DC80 to 264V 3 Power transmission DC0 to 1 25 to 2 5V...

Страница 17: ...ge Auxiliary supply 2 AC5A 2 Power transmission DC0 to 0 25 to 0 5V 200 or more AC80 to 264V Z Other Power receiving DC0 5 to 0 75 to 1V F DC80 to 264V 3 Power transmission DC0 to 1 25 to 2 5V 600 or...

Страница 18: ...Hitotsuya 1 chome Adachi ku Tokyo 121 8639 JAPAN TEL 81 3 3885 2411 FAX 81 3 3858 3966 Kyoto Office 1 19 Ichinobe Nishikawahara Jyoyou shi Kyoto 610 0114 JAPAN TEL 81 774 55 1391 FAX 81 774 54 1353 R...

Отзывы: