background image

Q-222-032 

 

 

Combination mounting dimension example (unit:mm) 
■ Screw mounting                       ■ IEC/DIN rail mounting 

   

 

 
 

■ How to install this product in a IEC / DIN rail. 

The claw of the upside of the slot for rail mounting in the bottom of this product is put in a rail. 
This product is fixable by pushing in the direction of an arrow below. 

35mm width DIN rail

Slider 

 

 

■ How to remove this product from the IEC / DIN rail. 

Please insert a flathead screwdriver in the hole where a slider is square.  Next, a slider is lowered in the 
direction of an arrow.  This product can be removed from the rail by pulling it up in the direction of the 
arrow.  However, the case may be damaged if this product is pulled up without lowering a slider completely. 

Flat-head screwdriver 

Slider 

 

 
 

②                    ① 

①:40mm width transducer. 
②:56mm width transducer. 
 
Please use rail of IEC, DIN technical standard 35mm width rail 
(strong type). 
《Recommendation product》 Fuji Electric Co., Ltd.   
                           TH35-15AL 

Содержание FSPTT2-92A-33

Страница 1: ...Q 222 032 INSTRUCTION MANUAL POWER FLOW THREE PHASE POWER FACTOR TRANSDUCER FSPTT2 92A 33...

Страница 2: ...ase do not install in the place where sunlight hits directly Discoloration and degradation of a name plate and deformation of the case by the surface temperature rise may occur If the average daily te...

Страница 3: ...our company Failure caused by violating various conditions regarding use storage etc specified by the supplier When the faults or defects are caused by a reason not belongs to purchased or delivered p...

Страница 4: ...thod 4 5 Connection 6 6 Handling explanation 7 7 Specification 7 1 Rating 7 7 2 Performance 8 7 3 Electrical strength Mechanical strength 9 7 4 Noise immunity 9 7 5 EMC 10 7 6 Structure and environmen...

Страница 5: ...with a width of 35mm The terminal cover is standard equipment 3 Bundled items Inspection certificate 1 Packed in an envelope Terminal screw in a bag M4 screw 4 piece set 1 M4 screw 7 piece set 1 4 Mo...

Страница 6: ...this product from the IEC DIN rail Please insert a flathead screwdriver in the hole where a slider is square Next a slider is lowered in the direction of an arrow This product can be removed from the...

Страница 7: ...g torque 1 0 to 1 3 N m Connection diagram 3 1 2 S1 AUX SUPPLY P1 1L 1S 3S S2 P2 OUTPUT A B 3L E LOAD Grounding is class D grounding grounding resistance 100 or less If there is a power line that caus...

Страница 8: ...ed current Indefinite 6 The output value when only the auxiliary power supply is applied or when the auxiliary power supply and voltage input are applied is the output equivalent to the power factor 1...

Страница 9: ...tment range is BIAS 5 of the output span MAX 5 of the output span Use only when adjustment is required for matching with connected devices Low input cut Output equivalent to the power factor 1 for pow...

Страница 10: ...ond of rated voltage 10 times 10 second intervals 40 times 1 second and 20 times 4 seconds and 10 times 16 seconds of rated current 2 times 1 minute intervals 10 times 1 second of rated current 5 time...

Страница 11: ...61000 4 6 Power frequency magnetic field immunity test Frequency 50 60Hz Field strength 30A m Performance standard A During testing Within 20 error After test Within inherent error EN61000 6 2 EN61000...

Страница 12: ...its 10 to 55 5 to 90 RH Non condensing Storage temperature limits 40 to 70 Product warranty period One year period 7 7 Technical standards Item Specification Transducer JIS C 1111 2019 IEC 60688 2012...

Страница 13: ...0 5 1 0 5 0 LEAD LAG LEAD LAG INPUT Power transmission Power receiving V mA 3 12 OUTPUT 5 20 1 4 4 16 2 8 0 0 5 1 0 5 0 0 5 1 0 5 0 LEAD LAG LEAD LAG INPUT Power transmission Power receiving V mA 2 5...

Страница 14: ...cated on the name plate or a simulated load with the same resistance value as the actual load 2 Apply the auxiliary power supply rated and the input equivalent to 50 of the rated output value and ener...

Страница 15: ...ving DC0 to 2 5 to 5V 3 DC20 to 57V 4 Power transmission DC0 to 5 to 10V 2k or more Z Other Power receiving DC0 to 5 to 10V 5 Power transmission DC1 to 3 to 5V 600 or more Power receiving DC1 to 3 to...

Страница 16: ...receiving DC3 to 4 to 5V 6 Power transmission DC 5 to 2 5 to 0V 600 or more Power receiving DC0 to 2 5 to 5V 7 Power transmission DC 10 to 5 to 0V 2k or more Power receiving DC0 to 5 to 10V A Power tr...

Отзывы: