10. Type composition 

 

Power Flow Current Transducer 

Type           Specification code 

F A E T T 2 - 9 2 A - 3 3 -

 

① ② ③ ④ ⑤

 

 

① Model 

 ② Input (

③ Rated voltage 

B  Model B 

Power transmission AC1 to 0A 

1  AC100V 

 

 

Power receiving AC0 to 1A 

2  AC105V 

 

 

Power transmission AC5 to 0A 

3  AC110V 

 

 

Power receiving AC0 to 5A 

4  AC115V 

 

 

Z  Other 

5  AC200V 

 

 

 

 

6  AC210V 

 

 

 

 

7  AC220V 

 

 

 

 

Z  Other 

 

④ Output (Output load range) (

⑤ Auxiliary supply 

Power transmission DC0 to 0.5V 

(200Ω or more) 

 

AC80 to 264V 

Power receiving DC0.5 to 1V 

F  DC80 to 264V 

Power transmission DC0 to 2.5V 

(600Ω or more) 

 

AC/DC power supply 

Power receiving DC2.5 to 5V 

3  DC20 to 57V 

Power transmission DC0 to 5V 

(2kΩ or more) 

Z  Other 

Power receiving DC5 to 10V 

 

 

Power transmission DC1 to 3V 

(600Ω or more) 

 

 

Power receiving DC3 to 5V 

 

 

Power transmission DC-5 to 0V 

(600Ω or more) 

 

 

Power receiving DC0 to 5V 

 

 

Power transmission DC-10 to 0V 

(2kΩ or more) 

 

 

Power receiving DC0 to 10V 

 

 

Power transmission DC0 to 0.5mA 

(10kΩ or less) 

 

 

Power receiving DC0.5 to 1mA 

 

 

Power transmission DC0 to 2.5mA 

(2kΩ or less) 

 

 

Power receiving DC2.5 to 5mA 

 

 

Power transmission DC0 to 5mA 

(1kΩ or less) 

 

 

Power receiving DC5 to 10mA 

 

 

Power transmission DC4 to 12mA 

(550Ω or less) 

 

 

Power receiving DC12 to 20mA 

 

 

Power transmission DC-1 to 0mA 

(10kΩ or less) 

 

 

Power receiving DC0 to 1mA 

 

 

Z  Other 

 

 

 

Note(

) The notation of the product body is Power transmission: REVERSE, Power receiving: NORMAL. 

 
 
 
 
 
 

   

 

      Tokyo Office : 11-13, Hitotsuya 1-chome, Adachi-ku, Tokyo, 121-8639, JAPAN. 
                     TEL:+81-3-3885-2411 , FAX:+81-3-3858-3966 

      Kyoto Office : 1-19, Ichinobe-Nishikawahara, Jyoyou-shi, Kyoto, 610-0114, JAPAN. 
                     TEL:+81-774-55-1391 , FAX:+81-774-54-1353 
 

       Revision B,  DATE:November 2, 2022 

 

Содержание FAETT2-92A-33

Страница 1: ...Q 222 030 INSTRUCTION MANUAL POWER FLOW CURRENT TRANSDUCER FAETT2 92A 33...

Страница 2: ...ase do not install in the place where sunlight hits directly Discoloration and degradation of a name plate and deformation of the case by the surface temperature rise may occur If the average daily te...

Страница 3: ...our company Failure caused by violating various conditions regarding use storage etc specified by the supplier When the faults or defects are caused by a reason not belongs to purchased or delivered p...

Страница 4: ...thod 4 5 Connection 6 6 Handling explanation 7 7 Specification 7 1 Rating 8 7 2 Performance 8 7 3 Electrical strength Mechanical strength 9 7 4 Noise immunity 9 7 5 EMC 10 7 6 Structure and environmen...

Страница 5: ...ipment 3 Bundled items Inspection certificate 1 Packed in an envelope Terminal screw in a bag M4 screw 10 piece set 1 4 Mounting method Please install indoors in a place with low mechanical vibration...

Страница 6: ...this product from the IEC DIN rail Please insert a flathead screwdriver in the hole where a slider is square Next a slider is lowered in the direction of an arrow This product can be removed from the...

Страница 7: ...N m Connection diagram Standard 2 phase S phase current measurement 1 phase R phase current measurement 3 phase T phase current measurement By changing the wiring 1 phase R phase current and 3 phase...

Страница 8: ...t will be burdened Especially for voltage output products do not short circuit the output This product will not be damaged even if the output terminal is left open in the current output specifications...

Страница 9: ...1 5A or less 5 3ms DC48V 3 1A or less 5 3ms Note Refer to the specification code for other ratings 7 2 Performance Item Specification Class index 0 5 Response time 1 second or less Ripple 1 p p or les...

Страница 10: ...ond of rated voltage 10 times 10 second intervals 40 times 1 second and 20 times 4 seconds and 10 times 16 seconds of rated current 2 times 1 minute intervals 10 times 1 second of rated current 5 time...

Страница 11: ...61000 4 6 Power frequency magnetic field immunity test Frequency 50 60Hz Field strength 30A m Performance standard A During testing Within 20 error After test Within inherent error EN61000 6 2 EN61000...

Страница 12: ...its 10 to 55 5 to 90 RH Non condensing Storage temperature limits 40 to 70 Product warranty period One year period 7 7 Technical standards Item Specification Transducer JIS C 1111 2019 IEC 60688 2012...

Страница 13: ...ent and attach the VR cap and terminal cover after adjustment 1 For the output load connect an actual load within the output load range indicated on the name plate or a simulated load with the same re...

Страница 14: ...or more Power receiving DC3 to 5V 6 Power transmission DC 5 to 0V 600 or more Power receiving DC0 to 5V 7 Power transmission DC 10 to 0V 2k or more Power receiving DC0 to 10V A Power transmission DC0...

Отзывы: