6-1
Chapter 6
W
elding Condition
Chapter 6 Welding Condition
This chapter explains the functions on the operation panel as well as how to set the welding conditions.
6.1 List of Welding Conditions
This section explains the parameters/functions settable in the welding power source.
6.1.1
Parameter (Welding parameter)
6.1.2
Function
Parameter
Set Range
Initial
Value
Descriptions
Three phase
Single phase
Pre-flow time
0 to 10 sec
0.1 sec
Set the gas discharge time before welding
starts.
Initialized condition/
Main condition/
Crater condition
Current
20 to 400 A
10 to 400 A
(for TIG
welding)
20 to 300 A
(for DC STICK
welding)
20 to 250 A
(for DC
welding)
20 to 200 A
(for pulse
welding)
10 to 250 A
(for DC TIG
welding)
20 to 200 A
(for pulse TIG
welding)
150 A
Initial Condition: set the current and voltage
value soon after the welding.
Welding condition: set the current and voltage
value during the welding.
Crater condition: set the current and voltage
value at the end of welding.
Voltage
(INDIVIDUAL)
10.0 to 45.0 V
10.0 to 30.0 V
23.5 V
Voltage
(SYNERGY)
-100 to 100
0
Post-flow time
0 to 10 sec
0.4 sec
Set the gas discharge time after the welding
ends.
Arc spot time
0.1 to 10 sec
3 sec
Set the welding time at arc spot.
Arc characteristics
-10 to 10
0
Set the arc to the condition from soft to hard.
Welding condition memory No.
1 to 100
1
Register the welding conditions (storable up to
100).
Wave frequency
0.5 to 32.0 Hz
3.0 Hz
Set the wave frequency at wave pulse.
Function
Initial value
Setting parameter
CRATER-FILL
CRATER-FILL-OFF
CRATER-FILL-OFF / CRATER-FILL-ON (no pulse) / CRATER-FILL-ON (with pulse) / ARC SPOT
GAS
MAG (20
%
CO
2
)
MAG (20
%
CO
2
) / MIG (2
%
O
2
) / MIG (100
%
Ar)
WIRE
MATERIALS
MILD STEEL
MILD STEEL / MILD STEEL CORED / STAINLESS STEEL / STAINLESS FERRITE /
STAINLESS CORED / Brazing Cu Si / Brazing Cu Al / SOFT ALUMINUM / HARD ALUMINUM
/ INCONEL
WELDING
METHOD
DC PULSE
DC PULSE / DC / DC WAVE PULSE / DC TIG / DC STICK
WIRE DIA.
[in.(mm)]
.045 (1.2)
.030 / .035 / .040 / .045 / .052 / 1/16 (0.8/0.9/1.0/1.2/1.4/1.6)
INITIAL
CONDITION
OFF
ON/OFF
VOLT. ADJUST
INDIV.
SYNERG. / INDIV.
Содержание OTC WB-P400
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18...
Страница 112: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Страница 130: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Страница 142: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Страница 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 16...