9-3
Chapter 9
T
roubleshooting
A
CTION
IN
C
ASE
OF
E
RROR
T
ROUBLESHOOTING
C
HAPTER
9
E-
615
Error of the backup memory
data (*2)
•
The error code will disappear when any key of the operation panel is pressed.
•
At the time, the welding conditions specified/registered and the settings of
internal functions may be initialized. After the error is cleared, check that
there is no problem in the data.
E-
700
An over current was detected at
the output side of the welding
power source (*1)
•
Check that the tip at the end of torch is not contacting the base metal.
•
Check that the power cables such as cables for base metal side and torch
side are not short-circuited.
•
The error code will disappear when the power switch is turned off.
E-
710
The phase W of input voltage for
primary side is disconnected
(*1)
•
Check that there is no problem in input voltage for primary side and in cable
wiring.
•
The error code will disappear when the power switch is turned off.
E-
800
801
The rotation rate of the motor of
wire feeder was not detected
(*1)
•
Check that there is no disconnection, short-circuit or other abnormalities in
the cables connecting the wire feeder.
•
Check that there is no problem in the wire feeder.
•
The error code will disappear when the power switch is turned off.
E-
810
The temperature of the governor
circuit exceeded the allowable
range (*1)
•
Check that the wires are not stuck or there are no other abnormalities in the
welding torch or wire feeder.
•
The error code will disappear when the power switch is turned off.
•
The "E-820" indication will disappear when any key of the operation panel is
pressed.
E-
820
The current in the wire feeder
motor exceeded the warning
level (*2)
E-
830
The current in the wire feeder
motor exceeded the WARNING
detection level (*1)
E-
951
There is a duplicate ID on a
single bus (*1)
•
Turn off the power switches of all other CAN-connected welding power
sources, then turn on the power switches and check the setting of internal
function F43. (
6.7.2.25
-
F43: CAN ID)
•
The error code will disappear when the power switch is turned off.
Error
-
code
Error cause
Action and how to cancel error
Содержание OTC WB-P400
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18...
Страница 112: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Страница 130: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Страница 142: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Страница 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 16...