DAIHAN Scientific, Forced Convection type Smart Oven                                                                                                  17/80 

 

The internal temperature rises up to 250

, so please be careful when opening or 

closing Air Duct or Door. 

The inner chamber is hot during an operation, do not touch the inner chamber 
without proper hand protection during operation as burns may occur. 

Do not operate this product near a heater or an air-conditioner. 

Clean the bottom of inner chamber and install the shelves properly before use. 

Do not close your face, hands or body into a chamber. It may cause an injury or 
burn by high temperature. 

 

Only operate unit after checking the safety of the unit. 

The temperature of the regulator SAFETY should be set up 30 ~ 40

C higher than 

the operating temperature. 
If the regulator SAFETY is set to 0, the heater does not operate. 

If unexpected sound, smell or smog is generated, pull the main plug out from the 
wall socket and contact the technical assets of DAIHAN Scientific 

If irradiated or contaminated samples are placed in the chamber, the warranty is 
voided. Do not use this product to sterilize or disinfect objects or samples. 

 

Do not use outdoors avoid overheating or electrical faults. The use in the place 
where the sun continuously shines and can get rained on it is prohibited. It may 
cause overheating or electrical fault of the product. 

 

Please do not use flammable or volatile products in the vicinity of the product to 
minimize the risk of firer. Please do not use the flammable spray such as lacquers 
and paint, or volatile, flammable chemicals and its similar product, in the 
proximity of the product. They may cause the ignition due to the spark of switch. 

 

Please avoid the disassembly or modification of this product by a non-authorized 
person to avoid serious electrical problems and to retain the warranty service of 
DAIHAN Scientific Co., Ltd. 

 

This product must be connected to a properly grounded power supply. 

 

Please regularly check whether dust or dirt are on the power plug and completely 
connect the plug. If the plug is covered with dust, or the connection is not 
complete, it will cause an electrical shock or fire. 

Please separate the power plug from the outlet for safety when the product is 
unused for long periods of time to avoid overheating or ignition due to dust. 

When disconnecting the power plug, it must be grasped by the hands and then 
pulled. Grasping only the cord and then disconnecting it may cause overheating or 
ignition because of internal lines being disconnected. 

Insert the plug securely into an appropriate wall socket. 
Loose connections result in excessive heat generation to the device and may 
cause arcing to occur at the connection. 

Содержание ThermoStable SOF-105

Страница 1: ...fied CE Certified PL Insurance Product Liability Insurance Validation IQ OQ Service User Manual Version 2 2 2 written for ThermoStableTM SOF 50 105 155 W105 W155 models ThermoStableTM SOF 105 Forced C...

Страница 2: ...DAIHAN Sci com or ALL forLAB com Shopping Mall DAIHAN Scientific Forced Convection type Smart Oven 2 80...

Страница 3: ...1 3 Product Configuration 6 2 Installation 2 1 Product Installation 7 2 2 Smart Lab WiReTM Service installation 9 2 3 Product Specifications 15 3 Product Usage 3 1 Precautions for Use 16 3 2 Names of...

Страница 4: ...the meaning Warning Failure to follow the instructions may result in injury Caution Failure to follow the instructions may result in product failure Proximity Caution Keep clear of the product during...

Страница 5: ...Controller 4 It sends the unusual condition in real time by the self testing system of the experimental equipment through WiReTM App Web Service support over the user and the service center and the r...

Страница 6: ...ndow 105Liter ThermoStable SOF 155 Smart Forced air Oven without Window 155Liter ThermoStable SOF W105 Smart Forced air Oven Built in Viewing Window 105Liter ThermoStable SOF W155 Smart Forced air Ove...

Страница 7: ...stalling or operating the product 8 Do not install the product in environments where inflammable gas may leak or may explode due to organic vapor gas 9 Make sure to prevent moisture organic solvent di...

Страница 8: ...ty Symbols on a product Safety symbols stickers Attached to side of product For meaning of each symbol please refer to Precautions Before Use Safety Instructions Product Liability PL Insurance Admissi...

Страница 9: ...is not installed when shipped This describes how to install WiReTM Service It only describes items that must be installed to use WiReTM Service Please refer to How to use page for more product operat...

Страница 10: ...ers Touch the date time box on the right If you randomly change the current time since supplied from the factory please be sure to use after re applying power to the equipment If you have changed the...

Страница 11: ...ack to the previous page if the blue return icon on the top right is clicked 2 Wifi Setup Set WiReTM Service is possible to use only if connected to internet Be sure to connect to a wireless LAN Conne...

Страница 12: ...connection is stable WiRe Mode is not possible if WiFi is not connected or network is unstable Make sure the network is stable It is possible to check Serial Number Model and Organization Name at belo...

Страница 13: ...and Name ID must be entered in at least more than 6 and less than 20 lowercase alphabetic characters and digits In cases of duplicate ID or less than 6 or more than 20 places other than lowercase uppe...

Страница 14: ...nd can monitor the status of device User can not remotely control After selecting an ID that wants to change authority from the registered user list set and select from Admin or User Since only one Ad...

Страница 15: ...ime Door open 30sec 8min to 100 8min to 150 6min to 100 6min to 150 Controller Smart LabTM Controller RS232 Port Available to connect with PC Display 4 Full Touch Screen TFT LCD Timer 99hr 59min delay...

Страница 16: ...or distress the power cord Please do not hurt on the power cord or process it or force bend it or pull it and tie it Also if heavy objects are placed over the power cord or the power cord is inserted...

Страница 17: ...y shines and can get rained on it is prohibited It may cause overheating or electrical fault of the product Please do not use flammable or volatile products in the vicinity of the product to minimize...

Страница 18: ...ogged please contact the deliverer or our technical service engineer Do not operate the unit before checking with an engineer otherwise it may cause an electrical shock or a fire The Sound Level of th...

Страница 19: ...tableTM SOF 105 155 W105 W155 2ea Controller Set and Check operation Window Safety Double Door Handle Door open and close Fig 3 2 3 Back of ThermoStableTM SOF 105 155 ThermoStableTM SOF W105 W155 Fig...

Страница 20: ...h Power ON OFF Fuse Protect unit from High Current Safety Switch Prevent overheat Fig 3 2 5 Standard Model ThermoStableTM SOF 105 Fig 3 2 6 Side of ThermoStableTM SOF ThermoStable SOF 50 120V 250V F 1...

Страница 21: ...trols operations OFF SET Set compensating temperature values CHART Monitors operational status in graph SETTINGS Sets various functions of device Error Notifies device s error WiFi connectivity Indica...

Страница 22: ...perature Setup screen by pressing SET button on the right where the set temperature is shown You can set the temperature at a 1 increment and can set between 25 to 250 Press ENTER after entering the s...

Страница 23: ...s 1 Running Mode After Power Failure It sets a mode for power is abruptly cut off and turned back up due to power supply issues such as power outage When setting a Stop mode It stands ready at the val...

Страница 24: ...atically operates at a temperature set that it previously operated on and the operation time on main screen continues its counting B Program Mode It restarts the count from the remaining time of first...

Страница 25: ...ctivated Set Fixed Operation Time Mode to ON and press Fixed Operation Time to set the value of timer It operates for a time it set when you start the product from main screen If Fixed Operation Time...

Страница 26: ...a target temperature after setting the segment time to reach the target temperature If the maintaining time for target temperature is not needed do not make second segment for the target temperature...

Страница 27: ...e device as Serial Number Model Temp Range and a version of Touch App Security Settings 1 Key Lock It requests password to access some key menu settings in menu Key Lock is activated by setting button...

Страница 28: ...ern can store up to 120 and a maximum of 100 segments can be stored in 1 Pattern Pattern is created by using button and in case you want to delete press the number of Pattern you want to delete and ve...

Страница 29: ...raph Enter the value of Segment after creating Pattern and Segment You can verify the temperature and time set for the Segment selected when you select Segment from the Segment window and touch You ca...

Страница 30: ...ted in the operation of Program Mode 1 Program button it enters into the Program setting screen rapidly 2 Step button It skips to next Segment while in operation 3 Hold button It temporarily stops whi...

Страница 31: ...mes and can be set to infinity by pressing button at 1 2 You can edit the order of operation after setting the number of repeat Select Start Segment and End Segment by pressing button from Sequence li...

Страница 32: ...can select from stored Pattern other than selected Pattern with Repeat operation it does not allow to operation in continuation of other Pattern after the Repeat operation if set to None Wait In opera...

Страница 33: ...internal memories at every 10 seconds and maximum 6 months of data are stored Please use Data Backup once every 6 months Temperature scope shown on graph can be changed using the set button on the lo...

Страница 34: ...pressing the point detailed information of the location emerges on a detail display You can check the information on graph by moving at a small increment of the point using arrows on the detail displa...

Страница 35: ...n see what happened in detail When malfunctions in the Touch Screen occur please press the Reset Button by inserting an appropriate tool such as a paper clip into the Reset hole which is located in th...

Страница 36: ...C 3 If not being used for a long period unplug and dry before packaging for storage 4 If replacement parts are required due to the failures while in use it must use the original parts supplied by the...

Страница 37: ...y of current temperature of product when slowly turning clockwise up to 320 after adjusting the Safety Knob to 0 4 Tak sound is Normal If Tak sound is not occurred A S is required 5 Please check the p...

Страница 38: ...regulated Heating but temperature is fluctuated Check the temperature that is currently set Make sure that the power switch is in the ON position Check that SAFETY Knob is not placed in the 0 position...

Страница 39: ...or 105 Lit OFS105 w455xd375mm DH WOF11155 Wire Shelf for 155 Lit OFS155 w520xd440mm Validation lQ OQ Service DH SWOF31050 Validation Service lQ OQ OFV1050 for ThermoStableTM SOF 50 DH SWOF31105 Valida...

Страница 40: ...all functions before shipment 2 This instrument is warranted for 2 years from purchasing date 3 A breakdown caused by customer s improper use or natural disaster is excepted from this warranty 4 This...