background image

Man266 (20 May. 2016)

 

 

Forced Convection type Smart Oven

 

Certifications by 

- - -

   

  ISO 9001 Certified. 
  ISO 13485 Certified   
  UL/CUL Certified 
  CE Certified 
  PL Insurance. (Product Liability Insurance) 
  Validation(IQ&OQ) Service. 

 

User Manual 

  (Version : 2.2.2) 

 

written for 

ThermoStable

TM 

SOF-50/-105/-155/-W105/-W155 models

 

 

 

 

 

 

 

 

 

 

 

 

 

“ThermoStable

TM 

SOF-105” 

Forced Convection type Smart Oven, 105Lit. 

 

DAIHAN-Sci.com or 

ALL

 

for

 

LAB.com

 Shopping Mall 

 

English Page : P. 

1

1 ~ 40 

 

Korean Page : P. 41 ~ 80 

Содержание ThermoStable SOF-105

Страница 1: ...fied CE Certified PL Insurance Product Liability Insurance Validation IQ OQ Service User Manual Version 2 2 2 written for ThermoStableTM SOF 50 105 155 W105 W155 models ThermoStableTM SOF 105 Forced C...

Страница 2: ...DAIHAN Sci com or ALL forLAB com Shopping Mall DAIHAN Scientific Forced Convection type Smart Oven 2 80...

Страница 3: ...1 3 Product Configuration 6 2 Installation 2 1 Product Installation 7 2 2 Smart Lab WiReTM Service installation 9 2 3 Product Specifications 15 3 Product Usage 3 1 Precautions for Use 16 3 2 Names of...

Страница 4: ...the meaning Warning Failure to follow the instructions may result in injury Caution Failure to follow the instructions may result in product failure Proximity Caution Keep clear of the product during...

Страница 5: ...Controller 4 It sends the unusual condition in real time by the self testing system of the experimental equipment through WiReTM App Web Service support over the user and the service center and the r...

Страница 6: ...ndow 105Liter ThermoStable SOF 155 Smart Forced air Oven without Window 155Liter ThermoStable SOF W105 Smart Forced air Oven Built in Viewing Window 105Liter ThermoStable SOF W155 Smart Forced air Ove...

Страница 7: ...stalling or operating the product 8 Do not install the product in environments where inflammable gas may leak or may explode due to organic vapor gas 9 Make sure to prevent moisture organic solvent di...

Страница 8: ...ty Symbols on a product Safety symbols stickers Attached to side of product For meaning of each symbol please refer to Precautions Before Use Safety Instructions Product Liability PL Insurance Admissi...

Страница 9: ...is not installed when shipped This describes how to install WiReTM Service It only describes items that must be installed to use WiReTM Service Please refer to How to use page for more product operat...

Страница 10: ...ers Touch the date time box on the right If you randomly change the current time since supplied from the factory please be sure to use after re applying power to the equipment If you have changed the...

Страница 11: ...ack to the previous page if the blue return icon on the top right is clicked 2 Wifi Setup Set WiReTM Service is possible to use only if connected to internet Be sure to connect to a wireless LAN Conne...

Страница 12: ...connection is stable WiRe Mode is not possible if WiFi is not connected or network is unstable Make sure the network is stable It is possible to check Serial Number Model and Organization Name at belo...

Страница 13: ...and Name ID must be entered in at least more than 6 and less than 20 lowercase alphabetic characters and digits In cases of duplicate ID or less than 6 or more than 20 places other than lowercase uppe...

Страница 14: ...nd can monitor the status of device User can not remotely control After selecting an ID that wants to change authority from the registered user list set and select from Admin or User Since only one Ad...

Страница 15: ...ime Door open 30sec 8min to 100 8min to 150 6min to 100 6min to 150 Controller Smart LabTM Controller RS232 Port Available to connect with PC Display 4 Full Touch Screen TFT LCD Timer 99hr 59min delay...

Страница 16: ...or distress the power cord Please do not hurt on the power cord or process it or force bend it or pull it and tie it Also if heavy objects are placed over the power cord or the power cord is inserted...

Страница 17: ...y shines and can get rained on it is prohibited It may cause overheating or electrical fault of the product Please do not use flammable or volatile products in the vicinity of the product to minimize...

Страница 18: ...ogged please contact the deliverer or our technical service engineer Do not operate the unit before checking with an engineer otherwise it may cause an electrical shock or a fire The Sound Level of th...

Страница 19: ...tableTM SOF 105 155 W105 W155 2ea Controller Set and Check operation Window Safety Double Door Handle Door open and close Fig 3 2 3 Back of ThermoStableTM SOF 105 155 ThermoStableTM SOF W105 W155 Fig...

Страница 20: ...h Power ON OFF Fuse Protect unit from High Current Safety Switch Prevent overheat Fig 3 2 5 Standard Model ThermoStableTM SOF 105 Fig 3 2 6 Side of ThermoStableTM SOF ThermoStable SOF 50 120V 250V F 1...

Страница 21: ...trols operations OFF SET Set compensating temperature values CHART Monitors operational status in graph SETTINGS Sets various functions of device Error Notifies device s error WiFi connectivity Indica...

Страница 22: ...perature Setup screen by pressing SET button on the right where the set temperature is shown You can set the temperature at a 1 increment and can set between 25 to 250 Press ENTER after entering the s...

Страница 23: ...s 1 Running Mode After Power Failure It sets a mode for power is abruptly cut off and turned back up due to power supply issues such as power outage When setting a Stop mode It stands ready at the val...

Страница 24: ...atically operates at a temperature set that it previously operated on and the operation time on main screen continues its counting B Program Mode It restarts the count from the remaining time of first...

Страница 25: ...ctivated Set Fixed Operation Time Mode to ON and press Fixed Operation Time to set the value of timer It operates for a time it set when you start the product from main screen If Fixed Operation Time...

Страница 26: ...a target temperature after setting the segment time to reach the target temperature If the maintaining time for target temperature is not needed do not make second segment for the target temperature...

Страница 27: ...e device as Serial Number Model Temp Range and a version of Touch App Security Settings 1 Key Lock It requests password to access some key menu settings in menu Key Lock is activated by setting button...

Страница 28: ...ern can store up to 120 and a maximum of 100 segments can be stored in 1 Pattern Pattern is created by using button and in case you want to delete press the number of Pattern you want to delete and ve...

Страница 29: ...raph Enter the value of Segment after creating Pattern and Segment You can verify the temperature and time set for the Segment selected when you select Segment from the Segment window and touch You ca...

Страница 30: ...ted in the operation of Program Mode 1 Program button it enters into the Program setting screen rapidly 2 Step button It skips to next Segment while in operation 3 Hold button It temporarily stops whi...

Страница 31: ...mes and can be set to infinity by pressing button at 1 2 You can edit the order of operation after setting the number of repeat Select Start Segment and End Segment by pressing button from Sequence li...

Страница 32: ...can select from stored Pattern other than selected Pattern with Repeat operation it does not allow to operation in continuation of other Pattern after the Repeat operation if set to None Wait In opera...

Страница 33: ...internal memories at every 10 seconds and maximum 6 months of data are stored Please use Data Backup once every 6 months Temperature scope shown on graph can be changed using the set button on the lo...

Страница 34: ...pressing the point detailed information of the location emerges on a detail display You can check the information on graph by moving at a small increment of the point using arrows on the detail displa...

Страница 35: ...n see what happened in detail When malfunctions in the Touch Screen occur please press the Reset Button by inserting an appropriate tool such as a paper clip into the Reset hole which is located in th...

Страница 36: ...C 3 If not being used for a long period unplug and dry before packaging for storage 4 If replacement parts are required due to the failures while in use it must use the original parts supplied by the...

Страница 37: ...y of current temperature of product when slowly turning clockwise up to 320 after adjusting the Safety Knob to 0 4 Tak sound is Normal If Tak sound is not occurred A S is required 5 Please check the p...

Страница 38: ...regulated Heating but temperature is fluctuated Check the temperature that is currently set Make sure that the power switch is in the ON position Check that SAFETY Knob is not placed in the 0 position...

Страница 39: ...or 105 Lit OFS105 w455xd375mm DH WOF11155 Wire Shelf for 155 Lit OFS155 w520xd440mm Validation lQ OQ Service DH SWOF31050 Validation Service lQ OQ OFV1050 for ThermoStableTM SOF 50 DH SWOF31105 Valida...

Страница 40: ...all functions before shipment 2 This instrument is warranted for 2 years from purchasing date 3 A breakdown caused by customer s improper use or natural disaster is excepted from this warranty 4 This...

Отзывы: