![Dahua VTO2000A Series Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/dahua/vto2000a-series/vto2000a-series_quick-install-manual_3225819003.webp)
3
VTO Camera Configuration
With a PC or Laptop connected to the network switch, run the Dahua config tool to find the VTO unit. By default the VTO has an IP
address of 192.168.1.110, this can be changed if required via the config tool or within the VTO web browser.
Login to the VTO via the computers web browser.
Username:
admin
Password:
admin
Select the
Local Config
tab and change
Device Type
to
Villa Station.
Click
OK
to save the setting.
Select the
Logout
option on the left menu and click
Reboot Device
, this will restart the VTO.
VTH Monitor Configuration
To configure the VTH unit use the built in menu within the monitor itself. VTH units do not support web browser configuration.
Select
Settings
>
Project Settings
and input the
engineer password:
002236
(default)
For DHI-VTH5221D units hold down the
Settings
button for 5 seconds and enter the
engineer password: 888888
(default)
The
Product Info
menu is used to set the room number of the VTH and to configure the unit as a Master or Extension unit. If
only a single VTH is being used in the system, then this should be set to Master and a room number chosen. Adding multiple
VTH units is covered on page 5.
Tel: +44 (0)1457 874 999 | Fax: +44 (0)1457 829 201 | Email: [email protected] | Online: www.cop-eu.com