14
1. Keep the convex groove outward and install the rubber ring into the network port, keep the smaller hole
of the rubber ring outward and install the fixing rubber ring into the main body of the waterproof
connector.
2. Pull the network cable without crystal head through main body of waterproof connector, fixing rubber ring
and waterproof locking cover, make the crystal head of network cable, and then insert it into the network
cable.
3. Put the main body of waterproof connector on the network port and rotate it clockwise to lock the
network port and waterproof connector firmly.
4. Put the waterproof locking cover on the main body of waterproof connector and rotate it clockwise to
lock the waterproof connector and waterproof locking cover firmly.
Step 4
Adjust the device.
Figure 3-4
Caution
Please make sure the adjusting screw is loosened when adjusting device direction and monitoring angle.
Tighten the adjusting screw firmly after adjustment is completed.
Please do not rotate the device body over 360
°
when the device body and mounting pedestal form an
angle of 90
°
and the adjusting screw is firmly tightened.
1. Open accessory bag, take out wrench and loosen the adjusting screw. Adjust the device in all possible
directions (UDLR) and rotate the device within 360
°
. Use the wrench to tighten the adjusting screw
firmly and make sure the bracket cannot be rotated after it meets the monitoring requirements.
2. The device sun shield can be moved forward and backward, it can be adjusted according to application
scenario. It needs to tighten the set screw on the sun shield firmly.