Environmental Precautions 

 

Transport, use, and store the unit within the specified temperature and humidity range.  

 

Do not place the unit in a wet, dusty, extremely hot or an extremely cold environment; and avoid 
environments with strong electromagnetic radiation or unstable lighting.  

 

Never push objects of any kind into this unit through openings as they may touch dangerous 
voltage points or cause a short circuit that may result in fire or electrical shock. Take care to not 
spill any liquid on the unit.  

 

Do not use units intended for indoor applications near water, in damp or wet environments, or in 
any area classified as a wet location. Do not expose an indoor unit to rain or moisture to reduce 
the risk of fire or electric shock. 

 

Do not block or cover any openings in the unit enclosure. These openings are provided for 
ventilation to prevent overheating and to ensure reliable operation. Ensure the unit is placed in 
an area with adequate ventilation.  

 

Do not place the unit near a heat source such as heaters, stoves, radiators or other equipment 
that produces heat. 

 

Use the following guidelines if placing the unit in a rack-mount: 

  The ambient temperature of a rack-mount environment may exceed the recommended 

operating temperature of the unit. Take care to read the ambient temperature before 
installation. 

  A rack-mount environment may restrict the movement of air. Ensure the unit receives the 

proper amount of air flow required for safe operation or install the unit elsewhere. 

  A rack mount is capable of supporting a maximum weight. Ensure the rack mount can support 

the additional weight of this unit. 

  A rack mount environment requires proper and adequate circuitry. Ensure the circuits to the 

rack are capable of handling the electrical requirements of all units in the rack to protect 
against circuit overloads. 

 

Pack the unit with standard factory packaging or material of the same quality when transporting 
the unit.  

 

Take care to avoid heavy stress, violent vibration, or water spills to the unit during transportation, 
storage, and installation. 

Operation and Daily Maintenance  

 

Do not touch the heat dissipation component of the unit. This part of the unit is hot and may 
cause a burn.  

 

Do not open or dismantle the device; there are no components that a user can fix or replace. 
Opening the unit may cause water leakage or expose components to direct light. Contact the 
manufacturer or a qualified service representative to service the camera or to replace a 
component, including the desiccant. 

 

Dahua recommends the use of a thunder-proof device in concert with the unit. 

 

Use a dry soft cloth to clean the unit’s housing. If the unit is particularly dusty, use water to dilute 
a mild detergent, apply the diluted detergent to a soft cloth, then gently clean the device. Finally, 
use a dry cloth to wipe the unit dry. Do not use a volatile solvent like alcohol, benzene, or thinner; 
or use a strong detergent with abrasives, which may damage the surface coating or reduce the 
working performance of the unit. 

Lithium Battery Disclaimer 

 

Improper use of the lithium battery shipped in this unit may result in fire, explosion, damage to 
the unit, and personal injury. 

 

If the need to replace the battery arises, ensure that the replacement battery is the same model 
as the original battery. 

WARNING:  

 

Risk of explosion if a different battery type is used a replacement. 

 

Dispose of used batteries according to the instructions of the battery manufacturer 
and local codes. 

                    Available from A1 Security Cameras 

    www.a1securitycameras.com email: [email protected]

Содержание N42B1P

Страница 1: ...Series 4K Network Video Recorder N42B1P N42B2P N42B3P Quick Start Guide Version 1 0 1 Dahua Technology USA Inc Available from A1 Security Cameras www a1securitycameras com email sales a1securitycamera...

Страница 2: ...iance 3 1 3 Legal Notices 3 Copyright 3 Trademarks 3 1 4 Disclaimer 3 2 Unpacking 4 3 NVR Components 5 3 1 Front Panel 5 3 2 Rear Panel 5 N42B1P 5 N42B2P 5 N42B3P 6 4 Installing the Hard Drive 7 5 NVR...

Страница 3: ...comply with EN 60950 Substitutions may damage the unit or cause fire or shock For 24 VAC units voltage applied to the unit s input power should not exceed 25 User supplied wiring must comply with loc...

Страница 4: ...sure the circuits to the rack are capable of handling the electrical requirements of all units in the rack to protect against circuit overloads Pack the unit with standard factory packaging or materia...

Страница 5: ...ed radio TV technician for help 1 3 Legal Notices Copyright This user guide is 2016 Dahua Technology Company LTD This user guide is the intellectual property of Dahua Technology Company LTD and is pro...

Страница 6: ...er support or your local representative The original packing carton is the safest container to transport the unit in the event the unit must be returned for service Retain the carton and all shipping...

Страница 7: ...malfunctioning NET Network status indicator A blue light indicates that the network connection is abnormal POWER Power status indicator A blue light indicates that the power connection is OK USB 2 0...

Страница 8: ...Output 4 RJ45 Port 1000 M 8 Alarm Input Output N42B3P Figure 3 4 Ref Name Ref Name Ref Name 1 Power Input 5 VGA Output 9 USB 2 0 Port 2 On Off Button 6 RS232 Port 10 RJ45 Port 1000 M 3 PoE Ports x 16...

Страница 9: ...er housing 3 Place the HDD under the HDD bracket in the chassis and align the four screw holes Affix the HDD to the chassis using a Philips screwdriver 4 Connect the HDD data cable to the maim board o...

Страница 10: ...ge protector The NVR enters the boot mode after power is applied and the NVR defaults to the multiple window video mode 5 2 Logging In The NVR has four built in accounts Username Password admin admin...

Страница 11: ...network cameras to the NVR at the same time There are two methods to access the Smart Add interface 1 Click the Smart Add button from the Startup Wizard screen Figure 6 1 2 Right click the Preview In...

Страница 12: ...e left pane Figure 7 1 3 Click the Device Search button located in the upper frame to search for remote devices on the network 4 Double click an IP address or check multiple devices and click the Add...

Страница 13: ...the address bar Internet Explorer opens the Login page 2 Click Yes to install webrec cab when the system displays the installation prompt Note If you receive an error that the computer cannot downloa...

Страница 14: ...9 7777 Fax 949 679 5760 Email sales usa global dahuatech com Rev 001 001 2017 Dahua All rights reserved Design and specifications are subject to change without notice Available from A1 Security Camera...

Отзывы: