Dahua EEC300D8-N1 Скачать руководство пользователя страница 23

 

19

 

We suggest you to change default HTTP and other service ports into any set of numbers 
between 1024~65535, reducing the risk of outsiders being able to guess which ports you are 
using. 

6.

 

Enable HTTPS 

We suggest you to enable HTTPS, so that you visit Web service through a secure communication 
channel. 

7.

 

MAC Address Binding 

We recommend you to bind the IP and MAC address of the gateway to the device, thus reducing 
the risk of ARP spoofing. 

8.

 

Assign Accounts and Privileges Reasonably 

According to business and management requirements, reasonably add users and assign a 
minimum set of permissions to them. 

9.

 

Disable Unnecessary Services and Choose Secure Modes 

If not needed, it is recommended to turn off some services such as SNMP, SMTP, UPnP, etc., to 
reduce risks. 
If necessary, it is highly recommended that you use safe modes, including but not limited to the 
following services: 

 

SNMP: Choose SNMP v3, and set up strong encryption passwords and authentication 
passwords. 

 

SMTP: Choose TLS to access mailbox server. 

 

FTP: Choose SFTP, and set up strong passwords. 

 

AP hotspot: Choose WPA2-PSK encryption mode, and set up strong passwords. 

10.

 

Audio and Video Encrypted Transmission 

If your audio and video data contents are very important or sensitive, we recommend that you 
use encrypted transmission function, to reduce the risk of audio and video data being stolen 
during transmission. 
Reminder: encrypted transmission will cause some loss in transmission efficiency. 

11.

 

Secure Auditing 

 

Check online users: we suggest that you check online users regularly to see if the device is 
logged in without authorization. 

 

Check device log: By viewing the logs, you can know the IP addresses that were used to log 
in to your devices and their key operations. 

12.

 

Network Log 

Due to the limited storage capacity of the device, the stored log is limited. If you need to save 
the log for a long time, it is recommended that you enable the network log function to ensure 
that the critical logs are synchronized to the network log server for tracing. 

13.

 

Construct a Safe Network Environment 

In order to better ensure the safety of device and reduce potential cyber risks, we recommend: 

 

Disable the port mapping function of the router to avoid direct access to the intranet 
devices from external network. 

 

The network should be partitioned and isolated according to the actual network needs. If 
there are no communication requirements between two sub networks, it is suggested to 
use VLAN, network GAP and other technologies to partition the network, so as to achieve 
the network isolation effect. 

 

Establish the 802.1x access authentication system to reduce the risk of unauthorized access 
to private networks. 

Содержание EEC300D8-N1

Страница 1: ...Data Collection Station Quick Start Guide V1 0 1...

Страница 2: ...hazard which if not avoided could result in slight or moderate injury CAUTION Indicates a potential risk which if not avoided could result in property damage data loss lower performance or unpredictab...

Страница 3: ...entilated place and do not block the ventilation of the Scanner Operate the Station within the rated range of power input and output Do not disassemble the Station Transport use and store the Station...

Страница 4: ...1 3 Power on 6 1 4 Device Connection 6 1 5 1 5 1 Connecting Control Module and Data Collection Module 6 1 5 2 Connecting Body Camera and Data Collection Module 6 2 HDD Installation 10 3 Configuration...

Страница 5: ...rol module can support 4 data collection modules at most It is featured with Recharge and collect data from maximum 32 body cameras at the same time Automatically or manually upgrade body cameras Auto...

Страница 6: ...2 Product Appearance 1 2 1 2 1 Control Module Front panel and rear panel Figure 1 1...

Страница 7: ...each user 4 Adjusting board Remove the control module when connecting control module and data collection modules 5 Rear cover 6 White light Provides extra light when recognizing faces Provides extra l...

Страница 8: ...ntrol module and data collection modules 10 Heat dissipation hole 11 Ports Include power input port USB ports Ethernet ports and RS 232 port For details see Table 1 2 1 2 2 Appearance of Data Collecti...

Страница 9: ...le 1 2 Port description No Name Description 1 Power input Inputs 100 V 240 V AC power for the Station After shutting down the Station the fan will work for a period to cool the Station 2 USB ports Con...

Страница 10: ...tion module according to the instruction on the positioning map Step 3 1 5 2 Connecting Body Camera and Data Collection Module After starting the Station connect body cameras to the Station and then y...

Страница 11: ...7 Take out data cable MPT220 slot Figure 1 5 Take out data cable MPT210 slot Figure 1 6 Connect the data cable to the body camera until the Station pops up connection successful Step 2 dialog box...

Страница 12: ...put the body camera into the dock and then you can collect data and Step 3 recharge the body camera For MPT220 body camera insert the device into the slot For MPT210 body camera insert the clip into...

Страница 13: ...9 Data collection MPT220 slot Figure 1 9 Data collection MPT210 slot Figure 1 10...

Страница 14: ...ach HDD we recommend you to install at least 2 HDDs with the same capacity for data collection and recharging Loosen the screws on the rear cover and then remove the rear cover Step 1 Remove rear cove...

Страница 15: ...s Step 4 Fix HDD Figure 2 4 Install HDDs Push the fixed HDDs in the HDD box Step 5 Install HDD Figure 2 5 Push HDDs in the direction as the HDD port and main board port show Fix the HDD box in the cha...

Страница 16: ...12 Connect the cable between main board and HDD plate Step 7 Fix the cover Step 8 Fix the cover Figure 2 7...

Страница 17: ...13 3 Configuration and Operation Main interface Figure 3 1 Table 3 1 Main interface description No Description 1 Unlock the dock by one tap 2 Alarm Tap it and the alarm tune is disabled...

Страница 18: ...each data collection module 9 View update methods of the Station and body cameras Click Bind Enforce on the Device Info interface enter the enforcer name and enforcer No click Search and then select...

Страница 19: ...15 User management Figure 3 2 Click Add to add users Step 2 You can add faces and fingerprints and configure user permissions All permissions are enabled by default Add users Figure 3 3...

Страница 20: ...users Enter enforcer department enforcer No enforcer name password and confirm password and add face and fingerprint as needed Adding enforcer Figure 3 4 3 2 3 Resetting Password Select Setting Accou...

Страница 21: ...17 Resetting password Figure 3 5...

Страница 22: ...ates function to obtain timely information of firmware updates released by the manufacturer We suggest that you download and use the latest version of client software Nice to have recommendations to i...

Страница 23: ...ve we recommend that you use encrypted transmission function to reduce the risk of audio and video data being stolen during transmission Reminder encrypted transmission will cause some loss in transmi...

Страница 24: ...20 Enable IP MAC address filtering function to limit the range of hosts allowed to access the device...

Отзывы: