User’s Manual
40
Submenu
Setting
TROUBLE
Select which areas the alarm from a bus communication fault between the
keypad and the controller must be sent to. In practice, an acoustic alarm
sounds when there is a loss of communication with the keypad (interruption
in communication between the keypad and the controller). If no area is
assigned, a keypad bus failure will not activate any acoustic alarm.
To assign or remove areas from the keypad, press the corresponding key (1
to 8) and then press
. The number of the assigned area appears on the
programming line to confirm that the selection was successful. The number
of the assigned Area disappears from the programming line to confirm that
the deselection was successful.
In the
SYSTEM FUNCTION
menu, you can then assign
TAMPER
or
TROUBLE
type alarms to a specific sound mode (
BUZZER
,
SIREN
, both or
SILENT
).
RAPID
Select which areas to adopt rapid arming without entering the access code.
Rapid arming can be allocated to one or more areas from this keypad. Press
the number of the Area to enable or disable the area. Press
to continue.
After at least one area is selected, the next programming steps
ARMING
(
DELAYED
or
IMMEDIATE
) and
FORCED ARM
(
YES
or
NO
) will be shown.
Press and hold
for three seconds to prompt rapid arming.
Rapid arming does not meet EN50131 standard.
ARMING
FORCED ARM
BUZ. ON/OFF
Enable or disable the keypad buzzer.
BUZ. ENTRY
Enable or disable the keypad buzzer for the entry delay.
BUZ. EXIT
Enable or disable the keypad buzzer for the exit delay.
BUZ. ALARM
Enable or disable the keypad buzzer for the sound of alarm.
BUZ. CHIME
Enable or disable the keypad buzzer for the sound of the chime alarm event.
KEYPAD BEEP
Enable or disable the beep when the keypad keys are pressed.
BACKLIGHT
Enable or disable automatic backlight illumination in the event of an alarm
or in the Entry Delay and Exit Delay status.
BUS ERRORS
Show the communication errors that have occurred between the keypad
and the controller.
Step 4
Press
to return to the keypads selection menu.
Then you can continue with programming other keypads, or press
to return to the
KEYPADS
menu from where you can press
and
to move to the next menu or
press
to exit from the installer menu.
7.4 Communicator
Step 1
After entering the installer menu, press
and
to scroll up and down until you reach
the
COMMUNICATOR
menu.
Содержание DHI-ARC3008C
Страница 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Страница 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Страница 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Страница 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Страница 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...
Страница 137: ...User s Manual...