10
Figure 3-14
Interface
Wiring Terminal
Description
Lock control output
NC1
Lock control of door 1
COM1
NO1
NC2
Lock control of door 2
COM2
NO2
Table 3-7
3.5.6 Wiring Description of Internal Alarm Output
Corresponding wiring terminals of internal alarm control output are shown in Table 3-8.
Interface
Wiring Terminal
Description
Internal
alarm
control output
NC1
Intrusion, overtime and vandal-proof
alarm output of door 1. Output time lasts
for 15s.
COM1
NO1
NC2
Intrusion, overtime and vandal-proof
alarm output of door 2. Output time lasts
for 15s.
COM2
NO42
Table 3-8
3.5.7 Wiring Description of Reader
1 door only supports to connect one type of reader
—485 or Wiegand.
Please refer to Table 3-9 for descriptions of wiring terminals corresponding to readers. Take
Door 1 for example, and other readers are the same as door 1. Please refer to Table 3-10 for
descriptions of video cable specification and length.
Interface
Wiring Terminal
Cable Color
Description
Entry Reader of
Door 1
485+
Purple
485 reader
485-
Yellow
LED
Brown
Wiegand reader
D0
Green
D1
White
CASE
Blue
GND
Black
Reader power supply