10
Note
It is recommended that the GND hole shall be connected to ground, which is to
improve device reliability.
Step 5 Install waterproof connector for network port, which is shown in Figure 2-3.
Figure 2-3
1) Keep the convex groove outward and install the rubber ring into the
network port, and keep the smaller hole of the rubber ring outward and
install the fixing rubber ring into the main body of the waterproof connector.
2) After pulling the network cable without crystal head through main body of
waterproof connector, fixing rubber ring and waterproof fastening cover,
make the crystal connector of network cable and then insert it into the
network cable.
3) Put the main body of waterproof connector on the network port and rotate it
clockwise to lock the network port and waterproof connector firmly.
4) Put the waterproof fastening cover on the main body of waterproof
connector and rotate it clockwise to lock the waterproof connector and
waterproof fastening cover firmly.
2.3
Device Installation (Bottom Cable Exit)
Pole-mounted PTZ can be used for pole-mounted bracket structure both indoors and
outdoors.
The hole sites of pole-mounted bracket should be matched with corresponding hole
sites of PTZ pedestal.
Pole-mounted bracket should sustain at least 8 times weight of PTZ.
Pole-mounted bracket has to be stable and reliable, it can't be installed in the
application environment which is not stable.
Note
Please make sure there is enough space in the bracket for pulling cables when it adopts
bottom cable exit.
Step 1 Replace cable exit location.