background image

 

 

 

 

 

 

 

IR Intelligent Speed Dome 

 

Installation Manual 

 

V1.0.1 

Содержание D-SD6AL233XA-HNR-IR

Страница 1: ...IR Intelligent Speed Dome Installation Manual V1 0 1...

Страница 2: ...of outsiders being able to guess which ports you are using 3 Enable HTTPS SSL Set up an SSL Certificate to enable HTTPS This will encrypt all communication between your devices and recorder 4 Enable...

Страница 3: ...ticast is used to share video streams between two recorders Currently there are no known issues involving Multicast but if you are not using this feature deactivation can enhance your network security...

Страница 4: ...ould result in property damage data loss lower performance or unpredictable result TIPS Provides methods to help you solve a problem or save you time NOTE Provides additional information as the emphas...

Страница 5: ...differences between the actual product and the Manual Please contact the customer service for the latest program and supplementary documentation There still might be deviation in technical data funct...

Страница 6: ...metal or inflammable in the product A failure to follow this instruction might result in fire short circuit or other damage Turn off the power and disconnect the power cable immediately if there is wa...

Страница 7: ...conforms to Limited Power Source according to IEC60950 1 Use the power adapter recommended by manufacturer For the product that supports laser do not aim the laser directly to eyes And keep a proper...

Страница 8: ...ing Resistance Setup 7 2 4 Reset Button and Micro SD Card 8 2 5 Speed Dome Installation 9 2 6 2 6 1 Installing Quick Mounting Connector 9 2 6 2 Speed Dome Cable 10 2 6 3 Installing the Speed Dome 12 3...

Страница 9: ...Cable Transmission Distance 29 Appendix 2 3 The Problems in Practical Application 29 Appendix 2 4 FAQ for RS 485 30 Cable Diameter 24V AC and Transmission Distance 31 Appendix 3 Cable Diameter 12V DC...

Страница 10: ...ceiling and wall can sustain at least eight times the weight of the speed dome and its mounting accessories Make sure the wall is thick enough to install expansion bolts The expansion bolts should be...

Страница 11: ...984 ft 300 m The above can be applied to HDCVI speed domes 1 3 2 Selecting the Power Cable See Appendix 3 for 24V AC power supply See Appendix 4 for 12V DC power supply See Appendix 5 for 24V DC powe...

Страница 12: ...ng the Package 2 2 Open the package and take out the speed dome See Figure 2 1 IR Speed Dome Figure 2 1 The speed dome appearances might be different depending on the model you purchased and the actua...

Страница 13: ...2 3 1 1 Analog Speed Dome Open the cover and there are two DIP switches on the PTZ mainboard for setting the speed dome address baud rate and parity See Figure 2 2 for the location of DIP switch DIP...

Страница 14: ...rate and parity It is 1 when you set the button as ON For address setup DIP 1 is the lowest bit and 8 is the highest bit for baud rate and parity setup DIP 1 is the lowest bit and 4 is the highest bi...

Страница 15: ...spectively 2 3 4 1 Analog Speed Dome Set the baud rate and parity for the analog speed dome 1 and 2 are for setting baud rate and 3 and 4 are for setting parity See Figure 2 5 Table 2 2 and Table 2 3...

Страница 16: ...s equipped on the power board and there are two connection methods See Figure 2 7 Connection methods of device terminal 120 resistance Figure 2 7 120 1 2 ON 2 3 OFF See Figure 2 8 for the default conn...

Страница 17: ...the cover on the speed dome and you can see the Reset button on the PTZ mainboard See Figure 2 10 Open the front dome component and you can see the Micro SD card slot on the ISP board of speed dome m...

Страница 18: ...about speed dome installation see 3 Wall mounted Bracket Installation to 6 Pole Mounted Bracket Installation The Manual takes analog speed dome installation with wall mounted bracket as the example 2...

Страница 19: ...ble video cable audio cable RS 485 control cable alarm cable network cable high frequency cable and optical fiber cable See Figure 2 13 Cables Figure 2 13 Speed dome cables might vary depending on the...

Страница 20: ...reserved on the wall mounted bracket with the corresponding cables of the speed dome as you need Then twine the cable connection with insulated rubber tape to ensure waterproof See Figure 2 15 Make su...

Страница 21: ...on web interface Step 4 2 6 2 4 Speed Dome GND Cable Connection Connect the YELLOW GREEN power cable to the lightning protection device and make sure the lightning protection device is well grounded...

Страница 22: ...IR Speed Dome Installation 13 Installation finished Figure 2 17...

Страница 23: ...Bracket Installation Dimension 3 1 See Figure 3 1 for wall mounted bracket and see Figure 3 2 and Figure 3 3 for dimension of the bracket and the quick mounting connector Wall mounted bracket Figure...

Страница 24: ...east eight times the weight of the speed dome and its mounting accessories 3 2 2 Installation Procedure Draw and drill four screw holes on the wall according to the bracket pedestal Insert Step 1 four...

Страница 25: ...Wall mounted Bracket Installation 16 Installing the speed dome with wall mounted bracket Figure 3 5...

Страница 26: ...4 1 for hang mounted bracket and see Figure 4 2 for dimension of the bracket Hang mounted bracket Figure 4 1 Dimension of hang mounted bracket mm Figure 4 2 The length of the hang mounted bracket is...

Страница 27: ...separate the connection plate and the connection pole of Step 1 the bracket Route the cables through the groove to the flange of the connection plate Fix the Step 2 connection plate on the ceiling wit...

Страница 28: ...n tape on the thread of the connection pole first and then fix the connection pole on the connection plate Install the speed dome on the hang mounted bracket see Figure 4 5 For details about Step 4 sp...

Страница 29: ...ion 20 5 Corner mounted Bracket Installation Dimension 5 1 See Figure 5 1 for corner mounted bracket and see Figure 5 2 for dimension of the bracket Corner mounted bracket Figure 5 1 Dimension of corn...

Страница 30: ...and drill the screw holes on the wall where there is the 90 included angle Step 1 according to the mounting hole on the corner mounted bracket pedestal and insert M8 expansion screws See Figure 5 3 Ro...

Страница 31: ...Corner mounted Bracket Installation 22 Installing the speed dome with corner mounted bracket Figure 5 4...

Страница 32: ...e Mounted Bracket Installation 23 6 Pole Mounted Bracket Installation Dimension 6 1 See Figure 6 1 for pole mounted bracket and see Figure 6 2 for dimension of the bracket Pole mounted bracket Figure...

Страница 33: ...all match with the dimension of the clamp The default clamp is the 5 inch clamp matches with the pole of 80 130 mm The clamp shall work with the pole mounted bracket and the diameter of the clamp is a...

Страница 34: ...u want to install the speed dome and adjust the diameter of the clamp to fix it on the pole See Figure 6 3 Pole mounted bracket Figure 6 3 CAUTION Make sure the clamp is firmly fixed on the pole Insta...

Страница 35: ...Pole Mounted Bracket Installation 26 Installing the speed dome with pole mounted bracket Figure 6 4...

Страница 36: ...oor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder prote...

Страница 37: ...reen GND wire or GND screw of the speed dome should be reliably connected by several strands of copper wire with no less than 25mm and indoor equipotential GND terminal See Appendix figure 1 2 for ind...

Страница 38: ...m In the following situations the Maximum transmission distance might become shorter The communication cable is thin There is strong electromagnetic interference in the environment There are too many...

Страница 39: ...t and speed dome are not matched Modify the baud rate and address of the host or speed dome Positive and negative polarities of RS485 cable are misconnected Switch the positive and negative polarities...

Страница 40: ...18 1017 75 310 21 20 122 13 37 23 190 83 58 16 298 17 90 88 763 31 232 66 25 97 70 29 78 152 66 46 53 238 53 72 71 610 65 186 13 30 81 42 24 82 127 22 38 78 198 78 60 59 508 87 155 10 35 69 79 21 27 1...

Страница 41: ...0 29 254 44 77 55 20 30 53 9 31 47 71 14 54 74 54 22 72 190 83 58 16 25 24 43 7 45 38 17 11 63 59 63 18 18 152 66 46 53 30 20 35 6 20 31 80 9 69 49 69 15 15 127 22 38 78 35 17 45 5 32 27 26 8 31 42 60...

Страница 42: ...Cable Diameter mm 0 8000 1 000 1 250 2 000 Transmission Distance Feet m 5 148 90 232 66 363 53 930 63 10 74 45 116 33 181 76 465 31 15 49 63 77 55 121 18 310 21 20 37 23 58 16 90 88 232 66 25 29 78 4...

Страница 43: ...mm 0 8000 1 000 1 250 2 000 Transmission Distance Feet m 5 335 03 523 48 817 94 2093 92 10 167 51 261 74 408 97 1046 96 15 111 68 174 49 272 65 697 97 20 83 76 130 87 204 48 523 48 25 67 01 104 70 16...

Страница 44: ...000 1 000 1 250 2 000 Transmission Distance Feet m 5 595 60 930 63 1454 11 3722 52 10 297 80 465 31 727 05 1861 26 15 198 53 310 21 484 70 1240 84 20 148 90 232 66 363 53 930 63 25 119 12 186 13 290 8...

Страница 45: ...110 37 41 0 00950 0 130 36 39 0 01327 0 140 35 0 01539 0 160 34 37 0 02011 0 180 33 0 02545 0 200 32 35 0 03142 0 230 31 0 04115 0 250 30 33 0 04909 0 290 29 31 0 06605 0 330 28 30 0 08553 0 350 27 2...

Отзывы: