    6 

 

The moving direction of the flow of people is toward the camera. During the test, the forehead of 

the  target  person  is  facing  the  camera.  It  is  better  to  stay  and  face  the  camera  for  temperature 

measurement. Temporary measures can be adopted on site to plan the walking route of personnel 

and guide the person to the camera position; for scenes with large indoor and outdoor temperature 

difference,  multiple  bow  type  routes  can  be  planned  and  the  area  with  wind  at  the  door  shall  be 

avoided,  and  the  temperature  measurement  can  be  conducted  after  the  person  reaches  the  indoor 

forehead temperature to be stable. 

 

The black body radiation surface (Note: the radiation surface shall not be touched or dirty) shall be 

facing  the  camera  irradiation  direction,  the  black  body  shall  be  on  the  left  or  right  side  of  the 

thermal imaging picture, and the tripod can be protected by temporary fence. 

 

As follows, black body is in the upper right corner of the image: 

 

 

It is required that the visible light channel has enough illumination and avoid the influence of backlight / 

reflection / change of strong light / occlusion, etc. 

 

It is forbidden to have high-temperature heat source or sunlight in the thermal imaging picture, to avoid 

the  interference  of  heat  source  such  as  heater,  hot  water  point,  microwave  oven,  high-power  lamp, 

radiator, etc., so as to avoid the damage of detector. 

 

The installation area shall be relatively isolated from the outside environment without wind and stability, 

to avoid the outdoor or the scene connected with the outside, which is not suitable for the environment 

with air flow or strong electromagnetic interference or vibration. 

Installation scenarios to avoid 

 

 

 

Insufficient light. 

Backlight / scene open 

to the outside       

      The direction of people moving is not toward 

the camera. 

Содержание BF Series

Страница 1: ...Installation and commissioning guide for temperature measurement for human body of Dahua thermal camera BF Series Zhejiang Dahua Technology Co Ltd...

Страница 2: ...ture exceeds 35 there is a possibility of fever For other environmental temperature conditions it is recommended to measure several samples on site and increase 1 as the alarm threshold on the basis o...

Страница 3: ...Preface II Change record Revision date Version number Creater Reviser 2020 01 27 V1 0 2020 01 28 V1 1 2020 01 31 V1 2 2020 02 03 V1 3...

Страница 4: ...tallation precautions 2 General settings 7 2 1 Device upgrade 2 2 Image debugging 2 3 Human body temperature detection function debugging 2 3 1 Select the intelligent scheme of human body temperature...

Страница 5: ...n of installation guidance video web operation guidance and guidance document should be obtained from the regional delivery supervisor In the future it will be synchronized in the group on the mobile...

Страница 6: ...stallation requirements are consistent with bf3221 7mm 1 3 Installation diagram Bf3221 3 5mm installation diagram Blac kbod y Height 2m Side view h u m a n Distance between two objects 2m Height of Bl...

Страница 7: ...istance between two objects 3m Height of Blackbody 1 8m Thermal camera focal length 13mm Blac kbod y Sidewalk width 1 5m Top view Thermal camera focal length 13mm 1 4 Real scene diagram BF3221 7mm as...

Страница 8: ...ween the camera and blackbody Thermal camera Height 2m Best test distance 3M Height of Blackbody 1 8m Personnel access direction 1 When the artificial diversion channel is lengthened as far as possibl...

Страница 9: ...r right side of the thermal imaging picture and the tripod can be protected by temporary fence As follows black body is in the upper right corner of the image It is required that the visible light cha...

Страница 10: ...upgraded item No 2 6 01 05 18388 If there is a new iterative process will be notified in the delivery group please pay attention to the group information in time The default to be restored after upgr...

Страница 11: ...ent scheme 2 2 2 Blackbody parameter setting Blackbody calibration Note the blackbody parameter setting steps are ignored for the scheme without blackbody a The actual setting of blackbody is 35 b Aft...

Страница 12: ...est temperature is within 35 0 2 on average 2 2 3 Drawing of human body temperature detection area a BF3221 7mm BF5401 13mm i The subject stands on the edge of the blackbody 3m away from the camera fa...

Страница 13: ...best temperature measurement distance and the measured temperature is generally high or low they can be compensated by temperature correction For example if it is 0 5 lower fill in 0 5 for temperatur...

Страница 14: ...11...

Страница 15: ...uracy or scrap so as to avoid the scratch of blackbody radiation surface and affect the temperature measurement accuracy Only for indoor use The use environment shall be free from obvious air convecti...

Страница 16: ...mperature measurement The actual temperature of the front face and the side face of the same person same position is different With masks the high temperature points are mainly in the forehead ears an...

Страница 17: ...ffect is not ideal please provide the Dav video with two channels on site Send Xu Fangrong and Fang Shengdong through Dahua interactive platform select intranet Download for outgoing type After receiv...

Отзывы: