26
Because configurations can be cleared on the management platform, and the access controller can
be initialized, you need to protect the platform access permission in case of data loss caused by
improper operation.
For active register parameter, see the table below.
Table 3-6
Active register
Name
Parameter
Server IP Address
IP address of the managing platform.
Port
Port number of the managing platform.
Device ID
Subordinate device number on the managing platform.
3.7.1.3
Wi-Fi
You can connect the access controller to the network through Wi-Fi if the access controller has Wi-Fi
function.
3.7.2
Serial Port Settings
Select serial input or serial output according to the entering direction and exiting direction.
Select
Connection > Serial Port
.
Serial port
Select
Serial Input
when external devices are with card reading and writing functions are
connected to the access controller.
Serial Input
is selected to enable access card information to
be sent to the access controller and the management platform.
For access controllers with face recognition, fingerprint recognition, card reading and writing
functions, if you select
Serial Output
, access controller will send lock/unlock information to the
access controller. There are two types of lock/unlock information:
User ID
Card No.
Select
OSDP Input
when card reader of OSDP protocol is connected to the access controller. The
access controller can send card information to the management platform.