background image

 

FAQ  25 

 

 

FAQ 

For  problems  not  included  hereinafter,  please  contact  local  customer  service  personnel  or 

consult headquarter customer service personnel. We will be always at your service. 

1.  Question:  After  pow

er  on,  power  indicator  doesn’t  turn  on  or  the  buzzer  doesn’t 

respond. 

Answer: Please check whether power plug is inserted in place. Please pull it out and insert it 

again. 

2. 

Question: After the reader is connected with the device, card swiping light doesn’t 
turn on, and it doesn’t respond after swiping a card. 

Answer:  Please  check  whether  reader  connector  is  inserted  in  place.  Please  pull  it  out  and 

insert it again; check whether reader contact light turns on. 

3.  Question: Client software fails to detect the device. 

Answer: Please check whether TCP/IP connector is connected properly, and whether device IP 

is in the same network segment. 

4.  Question: After swiping card, it prompts that card is invalid. 

Answer: Please check whether this card number has been added in the controller. 

5.  Question: Default IP of access controller. 

Answer: Default IP address is 192.168.0.2. 

6.  Question: Default port, initial user name and password of access controller. 

Answer: Default port is 37777, initial user name is admin and password is 123456. 

7.  Question: Online upgrade of the device. 

Answer: Connect the device and platform through network, and upgrade it at the platform. 

8.  Question:  Max.  wiring  distance  and  transmission  distance  of  card  reader  and 

controller. 

Answer: It depends on network cable type and whether it needs power supply of control relay. 

Connected with CAT5E network cable, typical value is: 

 

RS485, 100m. 

 

Wiegand, 100m. 

 

Содержание ASC1204B

Страница 1: ...Four door One way Access Controller User s Manual V1 0 0...

Страница 2: ...gularly change the credentials to your devices to help ensure that only authorized users are able to access the system 2 Change Default HTTP and TCP Ports Change default HTTP and TCP ports for systems...

Страница 3: ...em is set up for multiple users ensure that each user only has rights to features and functions they need to use to perform their job 10 UPnP UPnP will automatically try to forward ports in your route...

Страница 4: ...ras to the PoE Ports on the Back of an NVR Cameras connected to the PoE ports on the back of an NVR are isolated from the outside world and cannot be accessed directly 16 Isolate NVR and IP Camera Net...

Страница 5: ...ese limits are designed to provide reasonable protection against harmful interference in a commercial environment Operation of this equipment in a residential area is likely to cause harmful interfere...

Страница 6: ...ght collect personal data of others such as face fingerprints car plate number Email address phone number GPS and so on You need to be in compliance with the local privacy protection laws and regulati...

Страница 7: ...ations description or errors in print If there is any doubt or dispute please refer to our final explanation Upgrade the reader software or try other mainstream reader software if the Guide in PDF for...

Страница 8: ...put and output range Please don t dismantle the device arbitrarily Please transport use and store the device within allowed humidity and temperature range Power Requirement Please make sure to use bat...

Страница 9: ...and Output Rule 10 2 5 DIP Switch 10 2 6 Reboot 11 3 Smart PSS Config 12 3 1 Login Client 12 3 2 Add Access Controller 12 3 2 1 Auto Search 12 3 2 2 Manual Add 14 3 3 Add User 16 3 3 1 Card Type 17 3...

Страница 10: ...Table of Contents IX 7 Question Online upgrade of the device 25 8 Question Max wiring distance and transmission distance of card reader and controller 25 5 Technical Parameters 26...

Страница 11: ...larm 1 Support 5 groups of control output electric lock 4 and alarm output 1 With RS485 port it may extend to connect control module FLASH storage capacity is 16M which may extend to 32M Support max 1...

Страница 12: ...Overview 2 Figure 1 2...

Страница 13: ...ock and reader is shown in Figure 2 1 Figure 2 1 2 2 Device Installation There are two installation modes Mode 1 fix the whole device onto the wall with screws Mode 2 with U shaped guide rail hang the...

Страница 14: ...nto upper groove of the U shaped guide rail Step 3 Push the snap joint at the bottom of the device upwards The installation is completed when you hear the fitting sound 2 3 Disassembly If the device i...

Страница 15: ...e an alarm Device wiring diagram is shown in Figure 2 5 Figure 2 5 Interfaces are described in Table 2 1 Table 2 1 No Port Description No Port Description 1 RS485 communication 7 Reader of door 1 2 Ex...

Страница 16: ...and door contact are shown in Figure 2 6 Please refer to Table 2 3 for descriptions of wiring terminals Figure 2 6 Table 2 3 Port Wiring Terminal Description Exit button door contact PUSH1 Exit button...

Страница 17: ...y exit button of door 4 and door contact input of door 4 SR4 Door contact input of door 4 2 4 3 Wiring Description of Lock Support 4 groups of lock control outputs serial numbers after the terminals r...

Страница 18: ...only supports to connect one type of reader 485 or Wiegand Please refer to Table 2 5 for descriptions of wiring terminals corresponding to readers Take door 1 for example other readers are the same P...

Страница 19: ...ternal alarm input ports are able to connect smoke detector and IR detector etc When external alarm is triggered all doors are linked to be normally open GND 2 4 6 Wiring Description of Alarm Output W...

Страница 20: ...Input and Output Rule In case of alarm event the alarm continues for 15s Please refer to Table 2 9 for detailed alarm input and output rules Table 2 9 Alarm Type Alarm Signal Input Port Alarm Signal...

Страница 21: ...enters BOOT mode after start 1 3 5 and 7 are 1 while others are 0 After reboot the system restores factory defaults 2 4 6 and 8 are 1 while others are 0 After reboot the system restores factory defaul...

Страница 22: ...rts for different versions Please refer to actual port 3 1 Login Client Install the matching Smart PSS client and double click to run Carry out initialization configuration according to interface prom...

Страница 23: ...cific operations please refer to User s Manual of Smart PSS Client Step 3 Select the device that needs to be added and click Add The system pops up Prompt Step 4 Click OK The system displays Login Inf...

Страница 24: ...e port user name and password Alternatively double click the device to enter Modify Device interface Click this icon to enter Device Config interface and configure device camera network event storage...

Страница 25: ...fill in according to actual conditions Group Name Select the group of the device User Name and Password User name and password of the device Step 3 Click Add to add a device The system displays the ad...

Страница 26: ...Smart PSS Config 16 Figure 3 7 3 3 Add User Add users and bind with cards so as to distribute authority In New interface click Access to enter Access interface and complete access config here...

Страница 27: ...17 Figure 3 8 3 3 1 Card Type Card type shall be the same with card issuer otherwise it fails to read card number In Access interface click and then click to set the card type as shown in Figure 3 9...

Страница 28: ...gure 3 9 Figure 3 10 3 3 2 Single Add Add a single user send a card and input user info Step 1 In Access interface click and then click as shown in Figure 3 11 The system pops up Add User dialog box a...

Страница 29: ...Smart PSS Config 19 Figure 3 11 Figure 3 12 Step 2 Add user info manually including basic info fingerprint info and details Please refer to Table 3 3 for details...

Страница 30: ...e it only applies to guest card Valid Time set the valid time of card which is 10 years by default Picture user picture max 120K Card no and user ID cannot be repeated Fingerprint Info Collect fingerp...

Страница 31: ...Smart PSS Config 21 Figure 3 13 Step 2 Click Add The system pops up Add Door Group dialog box as shown in Figure 3 14 Figure 3 14...

Страница 32: ...to Door Group Select a door group add corresponding users to the group so all users in the group obtain authority of all doors in the group Step 1 In Access interface click and then click Access Level...

Страница 33: ...zation The search list filters user info without card number In the user list cancel the added user and delete the user s authority 3 5 2 Authorize According to User Select a user distribute door grou...

Страница 34: ...Smart PSS Config 24 Figure 3 17 Step 2 Click The system pops up Select Door Group dialog box as shown in Figure 3 18 Figure 3 18 Step 3 Select the door group and click OK to finish authorization...

Страница 35: ...ect the device Answer Please check whether TCP IP connector is connected properly and whether device IP is in the same network segment 4 Question After swiping card it prompts that card is invalid Ans...

Страница 36: ...of connected reader 4 groups Working power supply Rated voltage 10V 15V DC rated current 0 75A Period 128 Holiday 128 Unlocking mode Card card password password card or password card fingerprint finge...

Отзывы: