11
c. Alarm input needs the low level voltage signal.
d. Alarm input mode can be either NC (normal Open) or NO (Normal Close)
e. When you are connecting two NVRs or you are connecting one NVR and one other device,
please use a relay to separate them.
2. Alarm output
The alarm output port should not be connected to high power load directly (It shall be less than
1A) to avoid high current which may result in relay damage. Please use the co contactor to
realize the connection between the alarm output port and the load.
3. Please make sure the front-end device has soundly earthed.
Improper grounding may result in chip damage.
1.4.1 Alarm Input and Output Details
1.4.1.1 NVR 6000/6064 Series
You can refer to the following sheet
X
for alarm input and output information. See Figure 1-13.
Figure 1-13
Icon
Note
1
,
2
,
3
,
4
,
5
,
6
,
7
,
8
,
9
,
10
,
11
,
12
,
13
,
14
,
15
,
16
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
1-ON C
,
2-ON C
,
3-ON C
,
4-ON C
,
5-ON C
,
6-ON C
,
7-ON C
,
8-ON C
Eight groups of normal open activation output (on/off button)
G
GND cable.
A/B
The A/B cable to control the RS485 devices. It is to connect to
control decoder such as the recorder.
Tx and Rx
RS232 port. Tx is the data output cable and the Rx is the data input
cable.
1.4.1.2 NVR 608 Series
You can refer to the following sheet
X
for alarm input and output information. See Figure 1-14.