background image

 

  VI 

Operation and Maintenance Requirements 

 

Do not touch the heat dissipation component of the unit. This part of the unit is hot and 
may cause a burn.   

 

Do not open or dismantle the device; there are no components that a user can fix or 
replace. Opening the unit may cause water leakage or expose components to direct light. 
Contact the manufacturer or a qualified service representative to service the camera or to 
replace a component, including the desiccant. 

 

Dahua recommends the use of a thunder-proof device in concert with the unit. 

 

Do not touch the CCD or the CMOS optic sensor. Use a blower to clean dust or dirt on the 
lens surface. Use a dry cloth dampened with alcohol and gently wipe away any dust on 
the lens.   

 

Use a dry soft cloth to clean the unit’s housing. If the unit is particularly dusty, use water to 
dilute a mild detergent, apply the diluted detergent to a soft cloth, then gently clean the 
device. Finally, use a dry cloth to wipe the unit dry. Do not use a volatile solvent like 
alcohol, benzene, or thinner; or use a strong detergent with abrasives, which may damage 
the surface coating or reduce the working performance of the unit. 

 

Do not touch or wipe a dome cover during installation, this cover is an optical device. 
Refer to the following methods clean the dome cover:   

 

Stained with dirt: Use an oil-free soft brush or blower to gently remove the dirt. 

 

Stained with grease or fingerprints: Use a soft cloth to wipe gently the water droplet or the 
oil from the dome cover. Then, use an oil-free cotton cloth or paper soaked with alcohol or 
detergent to clean the lens from the center of the dome to outside. Change the cloth 
several times to ensure the dome cover is clean. 

WARNING 

 

Modify the default password after login. 

 

Use attachments and accessories only specified by the manufacturer. Any change or 
modification of the equipment, not expressly approved by Dahua, could void the warranty.   

 

Internal and external ground connection should be stable. 

 

Do not supply power via the Ethernet connection (PoE) when power is already supplied 
via the power connector.   

 

Disconnect power before device maintenance and overhaul. It is prohibited to open the 
cover with power on in an explosive environment. 

 

Please contact the local dealer or the nearest service center if the device fails to work 
normally, please don’t dismantle or modify the device. 

Содержание 59232XANR

Страница 1: ...59232XANR 2MP Starlight Network PTZ Camera Quick Installation Guide V1 0 1 Dahua Technology USA Inc ...

Страница 2: ...y damage data loss lower performance or unpredictable result NOTE Provides additional information as the emphasis and supplement to the text Revision History No Version Revision Content Release Time 1 V1 0 0 First Release January 2020 2 V1 0 1 Revised for North America June 2020 Privacy Protection Notice As the device user or data controller you may collect personal data such as face images finger...

Страница 3: ...tenance inconsistent with the information in this guide All the designs and software are subject to change without prior written notice The product updates may cause some differences between the actual product and the Guide Please contact the customer service for the latest program and supplementary documentation Video loss is inherent to all digital surveillance and recording devices therefore Da...

Страница 4: ...uarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipmen...

Страница 5: ...n accordance with applicable local codes All installation and operation must conform to your local electrical safety codes Do not overload outlets and extension cords which may cause fire or electrical shock Do not place the camera near or in a place where the camera may contact overhead power lines power circuits or electrical lights Ensure power conforms to SELV Safety Extra Low Voltage and that...

Страница 6: ...any fire or electrical shock caused by improper handling or installation Application Environment Requirements Please use the device within the allowed humidity 95 RH and altitude 3000m Transport use and store the unit within the specified temperature and humidity range Do not place the unit in a wet dusty extremely hot or an extremely cold environment and avoid environments with strong electromagn...

Страница 7: ...damage the surface coating or reduce the working performance of the unit Do not touch or wipe a dome cover during installation this cover is an optical device Refer to the following methods clean the dome cover Stained with dirt Use an oil free soft brush or blower to gently remove the dirt Stained with grease or fingerprints Use a soft cloth to wipe gently the water droplet or the oil from the do...

Страница 8: ...ccount name or the account name in reverse order Do not use sequential characters such as 123 abc etc Do not use repeated characters such as 111 aaa etc Change Default HTTP and TCP Ports Change default HTTP and TCP ports for systems These are the two ports used to communicate and to view video feeds remotely These ports can be changed to any set of numbers between 1025 and 65535 Avoiding the defau...

Страница 9: ...to perform their job Disable Unnecessary Services and Choose Secure Modes Turn off specific services such as SNMP SMTP and UPnP to reduce network compromise from unused services It is recommended to use safe modes including but not limited to the following services SNMP Choose SNMP v3 and set up strong encryption passwords and authentication passwords SMTP Choose TLS to access a mailbox server FTP...

Страница 10: ...nd IP Camera Network Ensure that the network for the NVR and IP cameras should not be the same network as a public computer network Separate networks prevent unauthorized users accessing the same network the security system Secure Auditing Check online users regularly to ensure unauthorized accounts are not logged in to a device Check the equipment log to access the IP addresses used to login to d...

Страница 11: ...arm Setup 4 2 4 1 Alarm Input 4 2 4 2 Alarm Output Level Application 5 2 4 3 Alarm Output Switch Application 5 Locally Storing Data 6 Using the Waterproof Ethernet Connector 6 Mounting the Camera 7 2 7 1 Preparing the Camera 8 2 7 2 Unpacking the Camera 8 2 7 3 Insert a MicroSD Card 9 Mounting the Camera to a Wall 10 3 Network Configuration 12 Initializing the Device 12 Modifying the IP Address 13...

Страница 12: ... to improve encoding efficiency while preserving high quality video The PTZ camera is equipped with quick and accurate pan tilt zoom control and True WDR for applications with direct sunlight or glare Parts List Package Item Quantity Network Camera 1 AC24V 3A Power Supply 1 PFB300S Wall Mount 1 PFA110 Mount Adapter 1 Roll of Teflon Tape 1 PTZ Manual 1 Quick Start Guide 1 Documentation CD 1 Pair of...

Страница 13: ...2 Dimension ...

Страница 14: ...ries Branch circuit protection incorporating a 20 A 2 pole Listed Circuit Breaker or Branch Rated Fuses are required as part of the building installation A readily accessible 2 pole disconnect device with a contact separation of at least 3 mm must be incorporated Warning DO NOT remove the protective film from the dome until the installation is complete to protect the dome from distortions from fin...

Страница 15: ... White Alarm IN Black Alarm GND Alarm Setup Certain devices support alarm inputs and outputs check your specific device for alarm capability 2 4 1 Alarm Input Refer to Figure 3 3 for alarm input configuration The device collects that status of the alarm input port when the input signal is idle or grounded If the input signal is connected to the 3 3 V or it is idle then the device receives the alar...

Страница 16: ... external pull up level is 5 V and the maximum port current is 5 mA Once the output increases the pull up resistance the alarm decreases the output voltage to the normal state low level at less than 0 8 V Figure 3 2 2 4 3 Alarm Output Switch Application The alarm output drives the external circuit with a maximum current of 30 mA and a maximum voltage of 5 V It is recommended to add a relay if the ...

Страница 17: ...ltimedia applications will at times have questionable quality and reliability Recording to the SD card is first in first out FIFO The camera deletes the oldest first entry as new storage requirements arise The camera does not signal nor make an indication when data is deleted Storage time is dependent on a variety of factors such as SD card size image resolution and video frames per second SD Reco...

Страница 18: ...apable of supporting a minimum of eight 8 times the weight of the camera and a bracket if used DO NOT connect the camera to the power supply during installation Warning DO NOT connect the camera to the power supply during installation Warning For units intended to be installed outdoors All wiring connecting to the unit must be routed separately inside a different permanently earthed metal conduits...

Страница 19: ... wall mount to the installation medium The hardware must be capable of supporting eight 8 times the weight of the camera and mount Appropriate tools to mount the camera to the wall 2 7 2 Unpacking the Camera Remove the camera the mount accessories and any hardware packages from the boxes Remove the camera from the plastic wrapping and place the camera dome end up in the foam packaging Remove the p...

Страница 20: ...the dome Remove the panel Unscrew the three 3 screws from the top of the camera module housing Remove the camera module housing Unscrew the four 4 module set screws then remove the camera module Insert the Micro SD card into the appropriate slot on the camera module Re assemble the camera module secure back into the dome and then replace the rear panel ...

Страница 21: ...bolt Drill a 50 mm approximately 2 in center hole to route the cables if necessary Insert an expansion bolt into each pre drilled perimeter hole if necessary Wrap several turns of Teflon tape around the threads on the PFA110 Mount Adapter Screw the PFA110 Mount Adapter block into the internal thread of the wall mount bracket until secure Tighten the set screw on the wall mount to secure the mount ...

Страница 22: ...d then push it to the end Then tighten the three M6 screws on the adapter block firmly Note Ensure the M6 screws are fixed tightly to secure the dome to the wall mount 10 Make the proper wiring connections and supply power to the camera Refer to Section 3 2 Wiring Note The video connection is covered by a heat shrink tube Once the video connection is made gently heat the tube to seal the connectio...

Страница 23: ...d the PC are on the same network segment The following figures and interfaces are for reference only and the actual product shall prevail Initializing the Device Double click the ConfigTool Icon on a PC to open the tool Click the IP Icon Click Search Setting Enter the start IP and end IP of the network segment in which you want to search devices and then click OK All the devices found in the netwo...

Страница 24: ...ect the devices whose IP addresses need to be modified and then click Modify IP Select Static mode and enter start IP subnet mask and gateway IP addresses of multiple devices will be set to the same if you select Same IP If DHCP server is available in the network devices will automatically obtain IP addresses from DHCP server when you select DHCP Click OK Accessing the Web Interface Each camera ca...

Страница 25: ...t Username and Password is admin Then click Login Install the controls according to the system prompt Once the controls are installed IE displays the Web Interface main page Modify the administrator password as soon as possible after you successfully logged in Configuring Alarms The device s Web Interface offers a Relay Activation page to configure alarms and to set alarm responses ...

Страница 26: ...trol the recording medium and to configure an alarm that triggers once the Micro SD card passes a pre determined storage Access the Web Interface for the device and click the Setup tab Expand the Storage menu then choose the Destination page Select the recording medium for each event Recorded and Snapshot event Scheduled Motion Detect and Alarm Select the Local check box to record an event to the ...

Страница 27: ...x to enable a relay alarm Then specify the time in seconds to delay the alarm relay output 10 s to 300 s Check the Send Email box to send an email to a specified user after the device triggers an alarm Set the capacity limit for the Micro SD Card available with the Capacity Warning event type The device triggers an alarm once the amount of data on the card surpasses this limit ...

Страница 28: ...e CA 92618 Tel 949 679 7777 Fax 949 679 5760 Support 877 606 1590 Sales sales usa dahuatech com Support support usa dahuatech com 2020 Dahua Technology USA All rights reserved Design and specifications are subject to change without notice ...

Отзывы: