Earthing
311
Earthing
Appendix 7
Appendix 7.1 What Is the Surge
Surge is a short current or voltage change during a very short time. In the circuit, it lasts for
microsecond. In a 220V circuit, the 5KV or 10KV voltage change during a very short time (about
microseconds) can be called a surge. The surge comes from two ways: external surge and
internal surge.
The external surge: The external surge mainly comes from the thunder lightning. Or it
comes from the voltage change during the on/off operation in the electric power cable.
The internal surge: The research finds 88% of the surge from the low voltage comes from
the internal of the building such as the air conditioning, elevator, electric welding, air
compressor, water pump, power button, duplicating machine and other device of inductive
load.
The lightning surge is far above the load level the PC or the micro devices can support. In most
cases, the surge can result in electric device chip damage, PC error code, accelerating the part
aging, data loss and etc. Even when a small 20 horsepower inductive engine boots up or stops,
the surge can reach 3000V to 5000V, which can adversely affect the electronic devices that use
the same distribution box.
To protect the device, you need to evaluate its environment, the lighting affection degree
objectively. Because surge has close relationship with the voltage amplitude, frequency,
network structure, device voltage-resistance, protection level, ground and etc. The thunder
proof work shall be a systematic project, emphasizing the all-round protection (including
building, transmission cable, device, ground and etc.). There shall be comprehensive
management and the measures shall be scientific, reliable, practical and economic.
Considering the high voltage during the inductive thundering, the International Electrotechnical
Commission (IEC) standard on the energy absorbing step by step theory and magnitude
classification in the protection zone, you need to prepare multiple precaution levels.
You can use the lightning rod, lightning strap or the lightning net to reduce the damage to the
building, personal injury or the property.
The lightning protection device can be divided into three types:
Power lightning arrester: There are 220V single-phrase lightning arrester and 380V
three-phrase lightening arrester (mainly in parallel connection, sometimes use series
connection ) You can parallel connect the power lightning arrester in the electric cable to
reduce the short-time voltage change and release the surge current. From the BUS to the
device, there are usually three levels so that system can reduce the voltage and release
the current step by step to remove the thunderstorm energy and guarantee the device
safety. You can select the replaceable module type, the terminal connection type and
portable socket according to your requirement.
Signal lightning arrester: This device is mainly used in the PC network, communication
system. The connection type is serial connection. Once you connected the signal lightning
Содержание 5216A-X
Страница 1: ...DIGITAL VIDEO RECORDER User s Manual V1 2 0 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD ...
Страница 45: ...Connecting Basics 32 Figure 4 2 ...
Страница 97: ...Local Configurations 84 Figure 5 50 ...
Страница 198: ...Local Configurations 185 Figure 5 153 Figure 5 154 Double click the video or click Step 7 ...
Страница 203: ...Local Configurations 190 Figure 5 158 Figure 5 159 ...
Страница 311: ...Glossary 298 Abbreviations Full term VGA Video Graphics Array WAN Wide Area Network ...
Страница 329: ...Earthing 316 ...