Blackbody: power on and preheat for 20 minutes; thermal imaging equipment: power 
on and preheat for 60 minutes, with the best effect. 

3. Whether it can be installed in outdoor or semi outdoor environment. 

Because  the  outdoor  temperature,  wind,  humidity  and  other  environmental  factors 
have a great impact on the temperature measurement of the thermal imaging surface, 
it is not recommended to be installed outdoors or in the area directly connected to the 
outdoor, but in a closed and relatively stable environment without wind. 

4. Why is it recommended to measure the temperature of frontal forehead? 

First of all, different people's forehead temperature also has temperature difference. In 
the  case  of  mask,  the  exposed  area  of  forehead  is  relatively  large,  which  is  more 
convenient for temperature measurement. 
The actual temperature of the front face and the side face of the same person / same 
position  is  different.  With  masks,  the  high  temperature  points  are  mainly  in  the 
forehead,  ears  and  neck,  and  the  temperature  is  different  among  different  people. 
Therefore, it is required to face the camera and test the frontal temperature uniformly 
to reduce the impact of temperature difference between different parts. 

5. What is the best temperature range for temperature measurement? 

The best temperature range of indoor wind free and stable environment is 10 

  ~ 

30 

 

6. The best distance for temperature measurement? 

The  best  temperature  measurement  distance  is  the  same  as  the  distance  between 
blackbody and equipment. 3.5mm detection distance is 2m, and the transverse width 
of 2m is about 1.5m; 7mm detection distance is 3m, and the transverse width of 3m is 
about 1.3m; the temperature measurement value far from the optimal distance will be 
reduced, and the temperature measurement value close to the optimal distance will be 
increased. 

7. How many heads can be tested? 

As shown in the figure below, in normal use, there are not many people (width 1.3-
1.5m) at the best distance of temperature measurement. There is no limit to the number 
of heads in the detection area, but it is too far or there is overlap, which may result in 
missing or inaccurate temperature measurement. It is recommended to test one by one. 

 

8. Why does the image of thermal imaging channel get stuck after a period of time? 
Is it normal? 

Normal. In order to ensure image uniformity and temperature measurement accuracy, 
thermal imaging needs a period of time to set the blank back to zero for correction. 
During the process of setting the blank, the image will get stuck once, and the internal 
part of the equipment will "click" once, which is a normal situation. 

9.  Why  thermal  imaging  does  not  measure  temperature  after  the  first 
configuration 

Содержание BF 5421

Страница 1: ...Thermal Camera Installation Guide BF 5421 V1 7 Zhejiang Dahua Technology Co Ltd...

Страница 2: ...exceeds 35 there is a possibility of fever For other environmental temperature conditions it is recommended to measure several samples on site and increase 1 as the alarm threshold on the basis of nor...

Страница 3: ...Change Record Revision date Version number Creater Reviser 2020 01 27 V1 0 2020 01 28 V1 1 2020 01 31 V1 2 2020 02 03 V1 3 2020 03 14 V1 7...

Страница 4: ...7 2 2 Debugging Of Human Body Temperature Detection Function 8 2 2 1 Selection of human body temperature measurement intelligent scheme 8 2 2 2 Blackbody Parameter Setting 8 2 2 3 Drawing Of Human Bo...

Страница 5: ...stalled in strict accordance with the specified height distance and other requirements The PPT version of installation guidance video web operation guidance and guidance document should be obtained fr...

Страница 6: ...is about 1 3m about one gate the forward temperature at 3m will be higher and the backward temperature will be lower The ideal situation is to place footprints at the 3m position to guide the thermome...

Страница 7: ......

Страница 8: ...n surface should be facing the camera If the blackbody is facing the camera the four sides of the blackbody shell will not be exposed as shown in the following figure The moving direction of the flow...

Страница 9: ...e blackbody put it on the top left or top right in the middle position of the Cross type It is required that the visible light channel has enough illumination and avoid the influence of backlight refl...

Страница 10: ...pay attention to the group information in time Note 1 After 20200210 the black regular box of the program is rectangle 2 Programs prior to 20200228 need to be upgraded to the latest first upgrade the...

Страница 11: ...scheme 2 2 2 Blackbody Parameter Setting Blackbody calibration Note the blackbody parameter setting steps are ignored for the scheme without blackbody a When the blackbody is actually set to 35 there...

Страница 12: ...osition of the Cross type on the top right as shown below c In the procedure before 20200210 the rule window should be in the middle of the black body the smaller the window is the higher the measurem...

Страница 13: ...wing figure e Confirm that the highest and lowest temperature is within 35 0 2 on average 2 2 3 Drawing Of Human Body Temperature Detection Area a BF5421 13mm i The subject stands on the edge of the b...

Страница 14: ...ional In normal scenes visible light is used to detect faces by default If the effect of visible light is not good such as backlight insufficient light etc thermal imaging detection can be used 2 The...

Страница 15: ...onsistent with the real ambient temperature on site If not please input the real and accurate ambient temperature on site use a thermometer to measure or point to measure the temperature of the tripod...

Страница 16: ...below is not checked otherwise the temperature measurement will be inaccurate If you have blackbody you need to turn on enable 2 2 5 Binocular Target Setting And Fine Adjustment Function 1 When selec...

Страница 17: ...2 2 6 Opening Closing Function Of Visual Face Thermometer Frame...

Страница 18: ...e test and calibration It is not allowed to change the boldface range without permission so as to avoid damaging the boldface or causing safety accidents It is not allowed to dismantle or refit blackb...

Страница 19: ...ne well and the black body shall be put into the packing box or covered with a clean cloth Ensure that the storage environment temperature and humidity are appropriate It is recommended to use neutral...

Страница 20: ...for temperature measurement The best temperature range of indoor wind free and stable environment is 10 30 6 The best distance for temperature measurement The best temperature measurement distance is...

Страница 21: ...two channels on site Send Xu Fangrong and Fang Shengdong through Dahua interactive platform select intranet Download for outgoing type After receiving the video the R amp D will optimize and iterate a...

Отзывы: