The number of connections available varies between controller models but all controllers have the same basic confi guration. Each 

controller can support at least one reader per door. Each door can also support push to exit, door sensor, lock output or an additional 

reader for two way systems.

When connecting Dahua readers to Dahua controllers, Wiegand connections are not required if RS485 is used.

Reader Connections

Purple Cable

RS485+ connection to controller

Power Input

DC/12V

Reset

12v

12v

12v

12v

GND

GND

GND

GND

Case

Case

Case

Case

D1

D1

D1

D1

D0

D0

D0

D0

LED

LED

LED

LED

485-

485-

GND

GND

GND

COM1

COM3

COM2

COM4

GND

GND

GND

485+

Push 2

OUT-

Push 3

Push 4

485-

485-

485+

485+

GND

Push 1

ALM-N

NC1

NC3

NC2

NC4

485-

SR1

OUT+

NO1

NO3

NO2

NO4

ADDRESS

DEFEND

SR2

SR3

SR4

485+

Yellow Cable

RS485-  connection to controller

Brown Cable

Wiegand LED connection to controller

Green Cable

Wiegand D0 connection to controller

White Cable

Wiegand D1 connection to controller

Blue Cable

Wiegand case/tamper connection to controller

Black Cable

Reader ground connection to controller

Red Cable

Reader 12v positive connection to controller

Connections

485+

LAN

TCP/IP

485 Card

Reader

485 

Communication

No.1

Door

Card

Reader

Unlock

+

Door

Sensor

Unlock

+

Door

Sensor

Lock 

Control 

Output

Lock 

Control 

Output

No.1

Door

Electric

Lock

No.3

Door

Electric

Lock

No.2

Door

Electric

Lock

No.4

Door

Electric

Lock

Alarm Input

Alarm Output

No.2

Door

Card

Reader

No.3

Door

Card

Reader

No.4

Door

Card

Reader

Platform

Platform

Card

Reader 

Power

Wiegand 

Card

Reader

As

Above

As

Above

As

Above

No.1 Door Unlock Button

No.1 Door Unlock Button

No.1 Door Unlock Button

No.1 Door Unlock Button

No.1 Door Sensor Input

No.1 Door Sensor Input

No.1 Door Sensor Input

No.1 Door Sensor Input

Power Off Unlock

Lock 12v Input

Power Off Lock

As

Above

As

Above

As

Above

Содержание ASI1212D

Страница 1: ...el 44 0 1457 874 999 fax 44 0 1457 829 201 email sales cop eu com web www cop eu com ACCESS CONTROL QUICK INSTALL GUIDE Please read this document before installation V1 Official UK distribution partne...

Страница 2: ...n be used in multiple installations scenarios with options for one door two door or four door controllers and one way or two way access The example below is based on a one door one way system Lock Rea...

Страница 3: ...ler Brown Cable Wiegand LED connection to controller Green Cable Wiegand D0 connection to controller White Cable Wiegand D1 connection to controller Blue Cable Wiegand case tamper connection to contro...

Страница 4: ...controller with built in keypad card ngerprint readers This unit supports a single door with the option to add an external reader for use as a two way system The example below is based on a one way sy...

Страница 5: ...used Purple Cable RS485 Yellow Cable RS485 Brown Cable Alarm Input Ground Green Cable Alarm Input White Cable Alarm Output Blue Cable Alarm Output Ground Black Cable Bell Red Cable Bell Connector 3 RJ...

Страница 6: ...lick the install buttton to install the tool on your computer Once the Toolbox has been installed an account must be registered before the con guration tools can be installed After installing and regi...

Страница 7: ...ay the admin login screen Enter the admin password followed by OK Default Settings Username admin Password 88888888 IP Address 192 168 1 108 2 Press the Up Down arrows to cycle through the menu option...

Страница 8: ...his password is used for logging into the software only and is not the password of the controller It is important to keep this password safe as failure to remember the password will result in not bein...

Страница 9: ...roller such as IP address Username Password the default port number is 37777 click Save to store the connection details The added controller should now show in the device list with the current status...

Страница 10: ...the Access icon from the Smart PSS home screen Once the access section has been opened the following screen will be shown The number of doors displayed depends on the controller type if a four door co...

Страница 11: ...ely any card readers connected to the controller can be used to scan a user card for enrolment purposes To choose the type of reader to be used select a reader device from the Card Issuer dropdown box...

Страница 12: ...long the new user is required access A permanent user could be given a number of years whereas an agency or temporary contract user could only be given a period of months or weeks If required an image...

Страница 13: ...n making sure that the user places their nger tip over the sensor at central to the sensor Select the details tab to enter additional user information such as Gender Title DOB contact information It i...

Страница 14: ...a single door list or multiple lists From the dropdown menu select Access Level Click the add button to create a new door list Enter a name for the doorlist a timezone can also be selected to limit ac...

Страница 15: ...ndow pane to display the users from that department click on the icon to adjust the users access rights Select the access menu icon Select a department from the left window pane to display the users f...

Страница 16: ...here to create a speci c time period where the door will remain locked such as weekends Keep Open Timezone A timezone can be con gured and selected here to create a speci c time period where the door...

Страница 17: ...ssback Select the access menu icon Click the Add button Select a controller from the dropdown list enter a reference name Select the anti passback con guration from the available options click OK to s...

Страница 18: ...ecting the View button from the access console page and selecting the cameras to view from the left window pane When incorporating Dahua access control and Dahua CCTV within SmartPSS it is possible to...

Страница 19: ...ify tab select whether SmartPSS should play a sound or not when the event occurs Select the link video tab and then choose which cameras should be pushed when the event occurs by double clicking on th...

Страница 20: ...COP UK Delph New Road Dobcross OL3 5BG England...

Отзывы: