3
The number of connections available varies between controller models but all controllers have the same basic confi guration. Each
controller can support at least one reader per door. Each door can also support push to exit, door sensor, lock output or an additional
reader for two way systems.
When connecting Dahua readers to Dahua controllers, Wiegand connections are not required if RS485 is used.
Reader Connections
Purple Cable
RS485+ connection to controller
Power Input
DC/12V
Reset
12v
12v
12v
12v
GND
GND
GND
GND
Case
Case
Case
Case
D1
D1
D1
D1
D0
D0
D0
D0
LED
LED
LED
LED
485-
485-
GND
GND
GND
COM1
COM3
COM2
COM4
GND
GND
GND
485+
Push 2
OUT-
Push 3
Push 4
485-
485-
485+
485+
GND
Push 1
ALM-N
NC1
NC3
NC2
NC4
485-
SR1
OUT+
NO1
NO3
NO2
NO4
ADDRESS
DEFEND
SR2
SR3
SR4
485+
Yellow Cable
RS485- connection to controller
Brown Cable
Wiegand LED connection to controller
Green Cable
Wiegand D0 connection to controller
White Cable
Wiegand D1 connection to controller
Blue Cable
Wiegand case/tamper connection to controller
Black Cable
Reader ground connection to controller
Red Cable
Reader 12v positive connection to controller
Connections
485+
LAN
TCP/IP
485 Card
Reader
485
Communication
No.1
Door
Card
Reader
Unlock
+
Door
Sensor
Unlock
+
Door
Sensor
Lock
Control
Output
Lock
Control
Output
No.1
Door
Electric
Lock
No.3
Door
Electric
Lock
No.2
Door
Electric
Lock
No.4
Door
Electric
Lock
Alarm Input
Alarm Output
No.2
Door
Card
Reader
No.3
Door
Card
Reader
No.4
Door
Card
Reader
Platform
Platform
Card
Reader
Power
Wiegand
Card
Reader
As
Above
As
Above
As
Above
No.1 Door Unlock Button
No.1 Door Unlock Button
No.1 Door Unlock Button
No.1 Door Unlock Button
No.1 Door Sensor Input
No.1 Door Sensor Input
No.1 Door Sensor Input
No.1 Door Sensor Input
Power Off Unlock
Lock 12v Input
Power Off Lock
As
Above
As
Above
As
Above