Refer to error display
in operation and function
Start
Change the
Comp.
Change Temp-Fuse
Y
N
N
Y
N
Y
Y
N
Y
N
Change OLP/PTC
Change the
defective motor
Change Main PCB
Check lead wire
Change the
Defrost heater.
Check ice formation on Eva.
and if refrigerant leak
is found, repair it.
N
N
Y
Y
Y
N
N
Defrost heater : 200W (
≒
66
Ω
)
(Left & Right side of Evaporator)
※
Left & Right side of evaporator
OLP/PTC
is OK?
Does Comp.
work?
Any error code
on Front PCB?
F-Fan & C-Fan
work ok?
F-Fan & C-Fan
motor is ok?
Wiring connection
is ok?
Temp-Fuse is ok?
(on the evaporator)
Defrost heater
Is ok?
Ice formation on Eva.
is ok?
Y
8-2-1. Freezing failure . (Foods are not frozen / cold.)
8-2. Freezer Compartment